Branch unit, EZ Meter-Pak, 125A, 6 x 5 jaw sockets, 208Y/120VAC, lever bypass, ringless, 1200A Al/Cu busbar

MTRING EZML BRANCH RINGLESS 6

SQDEZML316125X EZML316125X 785901068235
3775.87 / EA
http://schema.org/OutOfStock
  • Country of Origin: Mexico
  • Depth: 8.95 in
  • Enclosure Material: Steel
  • Number of Jaws: 5 With Jaw Release
  • Weight: 82000 g
Square D™ EZ Meter-Pak™ devices are the industry choice, providing better solutions to meet more multi-unit construction needs than any other line in the industry. EZM branch units are supplied with meter sockets and provisions for mounting tenant circuit breakers. The various EZ Meter Pak devices can have main ratings from 225 to 2000 A maximum depending on the version. Residential and commercial branches are available in ring or ringless type. This branch unit is ringless and rated 125A. It has 6 five jaw sockets for use. The system voltage is 208Y/120 VAC and has a lever bypass. It includes a 1200 A aluminium/copper busbar. It is compliant with UL standards and the steel enclosure has a rating of NEMA 3R.
QTY
  • Product Description
  • Features
  • Specifications
Square D™ EZ Meter-Pak™ devices are the industry choice, providing better solutions to meet more multi-unit construction needs than any other line in the industry. EZM branch units are supplied with meter sockets and provisions for mounting tenant circuit breakers. The various EZ Meter Pak devices can have main ratings from 225 to 2000 A maximum depending on the version. Residential and commercial branches are available in ring or ringless type. This branch unit is ringless and rated 125A. It has 6 five jaw sockets for use. The system voltage is 208Y/120 VAC and has a lever bypass. It includes a 1200 A aluminium/copper busbar. It is compliant with UL standards and the steel enclosure has a rating of NEMA 3R.
  • Features
    • Meter sockets and tenant circuit breaker slots for downstream metering and protection
    • 125A, 225A, and 400A units available, ringless or ring type with varied bypass options
    • 800A horizontal busbar standard (1200A busbar optional)
    • Corner, elbow, transition, and bus extensions create system design flexibility
    • NEMA Type 3R for outdoor and indoor installation
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • Bus Rated Current : 1200 A
    • Line Rated Current : 125 A
    • Ue Rated Operational Voltage : 208Y/120 V AC
  • Important Information Attributes
    • Carbon Footprint Of The Distribution Phase A4 : 29.28658476705032, 29 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 120 kg CO2 eq., 119.84670023008842
    • Carbon Footprint Of The Installation Phase A5 : 0.12162000586478833, 0.1 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 572 kg CO2 eq., 572.0063096033822
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : kg CO2 eq., 0
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-09-28
    • Return Indicator : Y
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 2532
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : No
    • With Recycled Cardboard : No
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Persona Type Ids : LC
    • Persona Type Names : Contractor
    • Tier Id : 2
    • Tier : 2
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Market Segmentation Id : COMMERCIAL
    • Market Segmentation : Commercial
    • Product Kit Identifier : N
    • Enclosure Material : steel
    • Energy Efficiency Optimized : False
    • Material : aluminium/copper: busbar
    • Meter Socket Type : ringless
    • Number Of Jaws : 5 with jaw release
    • Number Of Meter Sockets : 6
    • Phase : 3 phase in1 phase out
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : Meter Center Branch Unit
    • Range Of Product : Meter-Pak
    • Returnability : Yes
    • Software Version : v6.2.5-6
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 721 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Wiring Configuration : 4-wire
    • Database Version : 2024-01
    • Data Source : extrapolated product
    • Height Nominal : 75 in
    • Width Nominal : 15.38 in
    • Nbr. Of Units In Pkg. : 1
    • Customs Code : 8537109150
    • Warranty In Months : 18
    • Functional Unit Description : Other switchgear and controlgear solutions mentioned in the scope (e.g. fuses TC32, all-or-nothing relays TC94, Measuring relays and protection equipment TC95), apply the general rules of PCR and mention in the accompanying report the functional unit, the reference product characteristics, the reference lifetime and the use scenario which are applied consistently with the relevant IEC technical standards.Provide a single integrated enclosure or an assembly of enclosures, each with specified dimensions (H × L × D), designed to group control, command, and protection devices, ensuring protection of people from direct contact with live active parts, and offering mechanical impact resistance (IK rating) and ingress protection against solid objects and liquids (IP rating), while accommodating circuits with rated current (In), rated voltage (Ue), number of poles (Np) and rated breaking capacity (Icn) as applicable, and including any specific requirements, to protect the installation from overloads and short circuits according to the appropriate use scenario in household or commercial environments, and ensuring reliable operation throughout a reference service life of 20 years.
    • Functional Unit Quantity : 1
    • Functional Unit Unit : unit
    • Reference Lifetime In Y : 20
    • Recyclability Potential In % : 91
    • Pep End Of Validity Date Calculated : 2031-10-14
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • Mercury Free : Yes
    • Carbon Footprint : 721.2612146063857
    • Environmental Disclosure : ENVPEP2005009EN
    • Eu Rohs Directive : Compliant By Exemption
    • Nema Degree Of Protection : NEMA 3R
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2005009EN
    • Pep Verification Date : 2026-10-14
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Phase : 3 phase in1 phase out
    • Product Or Component Type : Meter Center Branch Unit
    • Range Of Product : Meter-Pak
  • Output Attributes
    • Bypass Type : lever bypass
  • Specifications
    • Country of Origin : Mexico
    • Weight : 82000 g
    • Depth : 8.95 in