SQUARE D

Anti Harmonic PowerLogic PFC detuned reactor, 25kvar 252Hz (4.2) 5.7% 60Hz 480V

Anti Harmonic PowerLogic PFC d

SQDLVR05250B48T LVR05250B48T 3606480541421
10136.58 / EA
http://schema.org/OutOfStock
  • Depth: 160 mm
The VarPlus detuned reactor are designed to protect the capacitor by preventing the amplification of the harmonics present in the system. Capacitors and Reactors are configured in Series resonant circuit. Tuned so that the series resonant frequency is below the lowest harmonic frequency present in the system. This reactor is rated for 25 kVar output power with 4.2/252 Hz tuning order at 480V AC at 60 Hz. Relative impedance, 5.7 %. This component meet the standards IEC 60068. This component require a forced convection, a fan need to be added. The case dimensions are 220mm in height, 240mm in width and 160mm in depth. For a product weight of 17.5 kg.
QTY
  • Product Description
  • Specifications
The VarPlus detuned reactor are designed to protect the capacitor by preventing the amplification of the harmonics present in the system. Capacitors and Reactors are configured in Series resonant circuit. Tuned so that the series resonant frequency is below the lowest harmonic frequency present in the system. This reactor is rated for 25 kVar output power with 4.2/252 Hz tuning order at 480V AC at 60 Hz. Relative impedance, 5.7 %. This component meet the standards IEC 60068. This component require a forced convection, a fan need to be added. The case dimensions are 220mm in height, 240mm in width and 160mm in depth. For a product weight of 17.5 kg.
  • Complementary Attributes
    • Maximum Current Irms : 36.7 A
    • Network Rated Voltage : 480 V AC 60 Hz
  • Important Information Attributes
    • Persona Type Ids : LC, OM, OM8, PB, SI
    • Persona Type Names : Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Harmonic Current Spectrum : 2.9 % x I3, 67.8 % x I5, 18.6 % x I7, 6.2 % x I11
    • Inductance Tolerance : - 5 % to 5 % per phase, - 5 % to 5 % per phase, - 5 % to 5 % per phase, - 5 % to 5 % per phase
    • Carbon Footprint Of The Distribution Phase [A4] : 15.344450827082886, 15 kg CO2 eq.
    • Carbon Footprint Of The End-of-life Phase [C1 To C4] : 38 kg CO2 eq., 37.90635135607772
    • Carbon Footprint Of The Installation Phase [A5] : 2.4196747282507647, 2 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 115 kg CO2 eq., 114.63088107437828
    • Carbon Footprint Of The Use Phase [B2, B3, B4, B6] : 2 267 kg CO2 eq., 2266.6800937787325
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-11-06
    • Return Indicator : Y
    • Stocking Flag : Y
    • Stock Policy : 2
    • Device Type : Surge Protection and Power Conditioning - Filters & Harmonic Conditioners
    • Serviceability : Yes
    • Traceability : Yes
    • Field Service Division : DPIBS
    • Service Catalog Item : Spare part
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant
    • Rohs Eur Conformity Date : 2402
    • Rohs Eur Full Compliance Status : Compliant
    • China Rohs In Scope : No
    • China Rohs Label : 1
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 3
    • Tier : 3
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Device Short Name : DR
    • Dielectric Test Voltage : 4 kV 60 Hz 1 minute
    • Dynamic Withstand Current : 2.2 x Isc
    • Electrical Insulation Class : class H
    • Energy Efficiency Optimized : False
    • Fixing Center : 200 x 125 mm
    • Network Frequency : 60 Hz
    • Power Losses : 200 W
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : detuned reactor
    • Range : PowerLogic
    • Reactive Power Rating : 25 kvar 480 V AC 60 Hz
    • Returnability : Yes
    • Software Version : v6.2.4
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 2 437 kg CO2 eq.
    • Type Of Cooling : forced convection
    • Value Of Inductance : 1.421 mH
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Tuning Order : 4.2 - 252 Hz - 5.7 % - 60 Hz
    • Fundamental Current Rating : 30.1 A
    • Pep Code : ENVPEP1212015EN
    • Database Version : 2023-02
    • Pep Verification Date : 2025-01-20
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional-unit Description : The use of detuned reactors thus prevents harmonic resonance problems, avoids the risk of overloading the capacitors and helps reduce voltage harmonic distortion in the network.
    • Functional-unit Quantity : 1
    • Functional-unit Unit : Unit
    • Reference Lifetime, In Y : 20
    • Energy Model - Manufacturing [A1-a3] : Czech Republic, CZ
    • Energy Model - Installation [A5] : Electricity Mix; Low voltage; 2018; Europe, EU-27
    • Energy Model - Use [B6] : Electricity Mix; Low voltage; 2018; Europe, EU-27
    • Energy Model - End Of Life [C1-c4] : Electricity Mix; Low voltage; 2018; Europe, EU-27
    • Recyclability Potential, In % : 1
    • Height Nominal : 220 mm
    • Width Nominal : 240 mm
    • Certificate Agency : IEC 60068
    • [Imp] Maximum Permanent Current : 1.3 x I1
    • [Ith] Conventional Free Air Thermal Current : 2 A 250 V AC 50 Hz
    • [Ui] Rated Insulation Voltage : 1.1 kV
    • Connections - Terminals : pad terminal
    • Nbr. Of Units In Pkg. : 1
    • Package Weight(Lbs) : 16.560 kg
    • Take-back : No
    • Warranty (In Months) : 18
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Ambient Air Temperature For Operation : 0-55 °C <= 3280.84 ft (1000 m), 0-50 °C > 3280.84...6561.68 ft (> 1000...2000 m)
    • Average Ambient Air Temperature For Operation : 50 °C <= 3280.84 ft (1000 m) average over 24 hours), 40 °C <= 3280.84 ft (1000 m) average over 1 year), 45 °C > 3280.84...6561.68 ft (> 1000...2000 m) average over 24 hours), 35 °C > 3280.84...6561.68 ft (> 1000...2000 m) average over 1 year)
    • Climatic Withstand : relative humidity 20...80 %, salt mist 400 V/50 Hz) 250 hours
    • Operating Altitude : <= 6561.68 ft (2000 m), <= 6561.68 ft (2000 m)
    • Take Back : No
    • Reach Free Shvc : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • Carbon Footprint : 2436.9814517645223
    • Environmental Disclosure : ENVPEP1212015EN
    • Eu Rohs Directive : Compliant
    • Ip Degree Of Protection : IP00
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Free Of Svhc : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1212015EN
    • Pep Verification Date : 2025-01-20
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : detuned reactor
  • ETIM
    • ETIM 8 : EC002565
    • ETIM 9 : EC002565
  • Specifications
    • Country of Origin : Czechia, France, United States
    • Depth : 160 mm