Altivar Soft Starter ATS130, 105A, 200 to 480V AC, control supply 24V DC

Altivar Soft Starter ATS130, 1

SQDATS130N2C11LT ATS130N2C11LT 3606486007440
1668.22 / EA
http://schema.org/OutOfStock
  • Depth: 180 mm
  • Display Type: 1 LED Green)control Power Energized1 LED Yellow And Red)motor Operation Phases, Errors
  • Operating Position: Vertical +/- 30 Degree
QTY
  • Features
  • Specifications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • Maximum Horse Power Rating : 30 hp 200 V normal duty, 30 hp 208 V normal duty40 hp 230 V normal duty75 hp 460 V normal duty, 75 hp 480 V normal duty
    • Maximum Switching Current : on inductive load for relay outputs : 1 A 30 V DC cos phi = 0.4 100000 cycles, on resistive load for relay outputs : 1 A 250 V AC 400000 cycleson resistive load for relay outputs : 1 A 30 V DC 400000 cycles, on inductive load for relay outputs : 1 A 250 V AC cos phi = 0.4 100000 cycles
    • Integrated Motor Overload Protection : false
    • Minimum Switching Current : 2.5 mA 24 V DC relay outputs
  • Important Information Attributes
    • Electromagnetic Compatibility : conducted and radiated emissions level B conforming to IEC 60947-4-2, short voltage interruptions level 3 conforming to IEC 61000-4-11, electrostatic discharge level 2 conforming to IEC 61000-4-2, radiated radio-frequency electromagnetic field immunity test level 1 conforming to IEC 61000-4-3electrical fast transient/burst immunity test level 2 conforming to IEC 61000-4-4oscillatory waves immunity level 3 conforming to IEC 61000-4-12voltage/current impulse level 2 conforming to IEC 61000-4-5conducted disturbances, induced by radiofrequency fields level 1 conforming to IEC 61000-4-6
    • Environmental Characteristic : without salt mist 3C3 IEC 60721-3-3, 3S3 IEC 60721-3-3
    • Function Available : deceleration voltage ramp, boost
    • Marking : CE, CCC, UKCA, RCM, EAC
    • Motor Power Kw : 30 kW 230 V normal duty55 kW 400 V normal duty, 55 kW 440 V normal duty
    • Protection Type : phase failure mainsthermal protection starter, bypass error starter, control voltage Us starter
    • Certificate Agency : CE, UKCA, CCC, RCM, EAC, UL
    • [Ue] Rated Operational Voltage : 200 V 30 hp normal duty, 208 V 30 hp normal duty230 V 40 hp normal duty, 230 V 30 kW normal duty400 V 55 kW normal duty, 440 V 55 kW normal duty460 V 75 hp normal duty, 480 V 75 hp normal duty
    • Carbon Footprint Of The Distribution Phase [A4] : 0.30178, 0.3 kg CO2 eq.
    • Carbon Footprint Of The End-of-life Phase [C1 To C4] : 0.37251, 0.4 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase [A5] : 0 kg CO2 eq., 0.0044923
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 163 kg CO2 eq., 163.42
    • Carbon Footprint Of The Use Phase [B2 B3 B4 B6] : 88 kg CO2 eq., 87.666
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-11-29
    • Return Indicator : Y
    • Stocking Flag : N
    • Stock Policy : 2
    • Device Type : Soft starter - Soft starter
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : IDIBS
    • Average Life Duration : 10 year(s)
    • Manufacturing Carbon Footprint : 163.42
    • Use Carbon Footprint : 87.666
    • Weee Applicability : Finished product
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2111001EN
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : No
    • Rohs Eur Status : Compliant
    • Rohs Eur Conformity Date : 2235
    • Rohs Eur Full Compliance Status : Compliant
    • China Rohs In Scope : Yes
    • China Rohs Label : 1
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Product Kit Identifier : N
    • Device Connection : in line
    • Device Short Name : ATS130
    • Display Screen Available : false
    • Display Type : 1 LED Green)control power energized1 LED yellow and red)motor operation phases, errors
    • Internal Bypass : true
    • Material Declaration : true
    • Operating Position : vertical +/- 30 degree
    • Operating Rate : 10 cyc/h
    • Overload Current : 300 % Ie for 5 s
    • Phase : 3 phase
    • Power Loss Per Device Current Dependent : 27 W
    • Power Loss Static Current Independent : 3 W
    • Power Losses : 703 W 300 % Ie
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Destination : asynchronous motors
    • Product Or Component Type : soft starter
    • Product Specific Application : simple machine
    • Range Of Product : Altivar Soft Starter ATS130
    • Returnability : Yes
    • Service Factor : 100
    • Software Version : EIME v5.9.3
    • Supply Frequency : 50...60 Hz +/- 5 Hz
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 252 kg CO2 eq.
    • Utilisation Category : AC-53A
    • Volume Of Cooling Air : 9 m3/h
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • With Safety Function Safe Programmable Logic : false
    • Torque Control : false
    • Control Power : 21.6 W starting and stopping3 W steady state
    • Minimum Motor Current : 20 % Ie
    • Rated Operational Current 2 : 105 A
    • Pep Code : ENVPEP2111001EN
    • Database Version : 2020-12
    • Pep Verification Date : 2022-03-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Type Of Verification For The Pep : Independent external review
    • Data Source : referent product
    • Functional-unit Description : Starting asynchonous motors with maximal current of 105A for at least 400.000 times. Calculation of the environmental impacts is based on 10 years of product service lifetime. The usage profile taken into account is 27,5% uptime in use phase at 75% loading rate, 22,5% uptime in stand by phase and 50% uptime in off phase.
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unit
    • Reference Lifetime In Y : 10
    • Energy Consumption On Product Lifetime In Kwh : 148.482
    • Energy Model - Manufacturing [A1-a3] : Energy model used: Germany
    • Energy Model - Installation [A5] : Electricity Mix; AC; < 1kV; EU-27
    • Energy Model - Use [B6] : Electricity Mix; AC; < 1kV; EU-27
    • Energy Model - End Of Life [C1-c4] : Electricity Mix; AC; < 1kV; EU-27
    • Recyclability Potential In % : 63
    • Height Nominal : 197 mm
    • Width Nominal : 81 mm
    • [Ie] Rated Operational Current : 105 A in line 40 °C)
    • [Uc] Control Circuit Voltage : +/- 10 %24 V DC
    • [Ui] Rated Insulation Voltage : 480 V
    • [Uimp] Rated Impulse Withstand Voltage : 4 kV
    • [Us] Rated Supply Voltage : 200...480 V - 15...10 %
    • Maximum Acceleration Under Shock Impact (During Operation) : 100 m/s² at 11 ms
    • Maximum Acceleration Under Shock Load (During Storage) : 100 m/s² at 11 ms
    • Maximum Acceleration Under Shock Load (During Transport) : 100 m/s² at 11 ms
    • Maximum Acceleration Under Vibrational Stress (During Operation) : 10 m/s² at 9...200 Hz
    • Maximum Acceleration Under Vibratory Load (During Storage) : 10 m/s² at 9...200 Hz
    • Maximum Acceleration Under Vibratory Load (During Transport) : 10 m/s² at 9...200 Hz
    • Maximum Deflection Under Vibratory Load (During Operation) : 3 mm at 2-9 Hz
    • Maximum Deflection Under Vibratory Load (During Storage) : 3 mm at 2-9 Hz
    • Maximum Deflection Under Vibratory Load (During Transport) : 3 mm at 2-9 Hz
    • On-load Factor : 70 %
    • With Safety Function Safe Brake Management (Sbc/Sbt) : false
    • With Safety Function Safe Direction (Sdi) : false
    • With Safety Function Safe Operating Stop (Sos) : false
    • With Safety Function Safe Position (Sp) : false
    • With Safety Function Safe Speed Monitor (Ssm) : false
    • With Safety Function Safe Stop 1 (Ss1) : false
    • With Safety Function Safe Torque Off (Sto) : false
    • With Safety Function Safely Limited Position (Slp) : false
    • With Safety Function Safely Limited Speed (Sls) : false
    • With Sft Fct Safe Stop 2 (Ss2) : false
    • Carbon Footprint (Kg Co2 Eq Total Life Cycle) : 251.77
    • Nbr. Of Units In Pkg. : 1
    • Package Weight(Lbs) : 2.548 kg
    • Take-back : No
    • Warranty (In Months) : 18
    • Air Pollution (M3) Total Life Cycle : 21394
    • Air Pollution (M3) Manufacturing [A1-a3] : 17597
    • Air Pollution (M3) Distribution [A4] : 12.838
    • Air Pollution (M3) Operational Energy Use [B6] : 3759.7
    • Air Pollution (M3) End Of Life [C1-c4] : 24.534
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Total Life Cycle : 3020.1
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Manufacturing [A1-a3] : 2110
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Distribution [A4] : 4.2398
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Operational Energy Use [B6] : 903.07
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) End Of Life [C1-c4] : 2.7809
    • Global Warming (Kg.Equivalent.Co2) Total Life Cycle : 251.77
    • Global Warming (Kg.Equivalent.Co2) Manufacturing [A1-a3] : 163.42
    • Global Warming (Kg.Equivalent.Co2) Operational Energy Use [B6] : 87.666
    • Hazardous Waste Disposed Of (Kg) Total Life Cycle : 262.43
    • Hazardous Waste Disposed Of (Kg) Manufacturing [A1-a3] : 259.23
    • Hazardous Waste Disposed Of (Kg) End Of Life [C1-c4] : 3.2019
    • Materials For Recycling (Kg) Total Life Cycle : 1.5538
    • Materials For Recycling (Kg) Manufacturing [A1-a3] : 0.061
    • Materials For Recycling (Kg) End Of Life [C1-c4] : 1.4102
    • Net Use Of Fresh Water (M3) Total Life Cycle : 3.155
    • Net Use Of Fresh Water (M3) Manufacturing [A1-a3] : 2.926
    • Non-hazardous Waste Disposed Of (Kg) Total Life Cycle : 364.56
    • Non-hazardous Waste Disposed Of (Kg) Manufacturing [A1-a3] : 36.618
    • Non-hazardous Waste Disposed Of (Kg) Operational Energy Use [B6] : 327.92
    • Radioactive Waste Disposed Of (Kg) Total Life Cycle : 0.2793
    • Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Total Life Cycle : 3937.5
    • Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Manufacturing [A1-a3] : 2280.7
    • Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Distribution [A4] : 4.2613
    • Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Operational Energy Use [B6] : 1649
    • Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) End Of Life [C1-c4] : 3.4604
    • Total Use Of Primary Energy During The Life Cycle (Mj) Total Life Cycle : 4156.3
    • Total Use Of Primary Energy During The Life Cycle (Mj) Manufacturing [A1-a3] : 2372.4
    • Total Use Of Primary Energy During The Life Cycle (Mj) Distribution [A4] : 4.267
    • Total Use Of Primary Energy During The Life Cycle (Mj) Operational Energy Use [B6] : 1776.1
    • Total Use Of Primary Energy During The Life Cycle (Mj) End Of Life [C1-c4] : 3.4642
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Total Life Cycle : 218.76
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Manufacturing [A1-a3] : 91.674
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Operational Energy Use [B6] : 127.08
    • Use Of Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Total Life Cycle : 13.468
    • Use Of Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3] : 13.468
    • Use Of Non-renewable Primary Energy Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Total Life Cycle : 3924.1
    • Use Of Non-renewable Primary Energy Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3] : 2267.3
    • Use Of Non-renewable Primary Energy Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Distribution [A4] : 4.2613
    • Use Of Non-renewable Primary Energy Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : 1649
    • Use Of Non-renewable Primary Energy Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) End Of Life [C1-c4] : 3.4604
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Total Life Cycle : 218.76
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3] : 91.674
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : 127.08
    • Water Eutrophication (Kg.Equivalent.P04 3-) Total Life Cycle : 0.0858
    • Water Pollution (M3) Total Life Cycle : 14410
    • Water Pollution (M3) Manufacturing [A1-a3] : 10641
    • Water Pollution (M3) Distribution [A4] : 49.628
    • Water Pollution (M3) Operational Energy Use [B6] : 3678.5
    • Water Pollution (M3) End Of Life [C1-c4] : 39.69
    • [In] Rated Current Pwr Loss Specifctn2 : 105 A
    • Customs Code : 8537109170
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : -10-40 °C (without derating), -10-40 °C (without derating)-10-40 °C (without derating), -10-40 °C (without derating)40-60 °C (with current derating of 2 % per °C)
    • Ambient Air Temperature For Storage : -25-70 °C, -25-70 °C
    • Ambient Air Transport Temperature : -40-70 °C, -40-70 °C
    • Take Back : No
    • Reach Free Shvc : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 251.77
    • Circularity Profile : ENVEOLI2111001EN
    • Environmental Disclosure : ENVPEP2111001EN
    • Eu Rohs Directive : Compliant
    • Ip Degree Of Protection : IP20
    • Operating Altitude : 0...3280.84 ft (0...1000 m) without derating3280.84...13123.36 ft (1000...4000 m) 1 % per 100 m
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Free Of Svhc : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Relative Humidity : 5-95 % non condensing without dripping water IEC 60068-2-3
    • Pep Code : ENVPEP2111001EN
    • Pep Verification Date : 2022-03-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Phase : 3 phase
    • Product Or Component Type : soft starter
    • Range Of Product : Altivar Soft Starter ATS130
  • ETIM
    • ETIM 8 : EC000640
    • ETIM 9 : EC000640
  • Output Attributes
    • Discrete Output Number : 1
    • Discrete Output Type : non programmable digital output DQ1 <= 30 V 200 mA
    • Relay Output Number : 1
    • Relay Output Type : relay outputs R1A, R1C NO
  • Input Attributes
    • Discrete Input Type : DI) digital input, 10 kOhm, DI2) digital input, 10 kOhm, BOOST) digital input, 10 kOhm
    • Discrete Input Logic : digital input 0... 13 V, >= 0.5 mA
    • Discrete Input Number : 3
    • Input Compatibility : discrete input level 1 PLC EN/IEC 61131-2
  • Specifications
    • Country of Origin : Brazil, Germany, France
    • Depth : 180 mm