SQUARE D

Advanced control unit, TeSys Ultra, 8A to 32A, 1P motors, protection & diagnostic, class 10, coil 24VDC

ADV.CNTRL.UNIT-CL10-1PH 8-32A

SQDLUCC32BL LUCC32BL 3389110364514
198.65 / EA
http://schema.org/OutOfStock
  • Country of Origin: Brazil
  • Depth: 60 mm
  • Load Type: Single-phase Motor
  • Warranty Length: 18 mth
TeSys U control and diagnostic unit to be inserted in advanced power bases LUB320, LUB380 to form a TeSys U starter controller, for 1-phase motor applications up to 7.5kW@400V. It provides full protection to motors with a rated current Ir 8-32A (Ir adjustable), overload tripping class 10, short circuit at 13 x Irmax, overcurrent at 14.2 x Ir, phase loss, insulation fault (protection of equipment only). It provides a thermal overload alarm to be used locally using a LUFDA module or remotely using a LULC module, and a test push button for overload simulation. To be used with a 24V DC voltage for the control of the starter (through the control terminals A1/A2 located in the power base). Certified when used in conjunction with a LUB power base (IEC, UL, CSA, CCC, EAC, Marine).
QTY
  • Product Description
  • Features
  • Specifications
TeSys U control and diagnostic unit to be inserted in advanced power bases LUB320, LUB380 to form a TeSys U starter controller, for 1-phase motor applications up to 7.5kW@400V. It provides full protection to motors with a rated current Ir 8-32A (Ir adjustable), overload tripping class 10, short circuit at 13 x Irmax, overcurrent at 14.2 x Ir, phase loss, insulation fault (protection of equipment only). It provides a thermal overload alarm to be used locally using a LUFDA module or remotely using a LULC module, and a test push button for overload simulation. To be used with a 24V DC voltage for the control of the starter (through the control terminals A1/A2 located in the power base). Certified when used in conjunction with a LUB power base (IEC, UL, CSA, CCC, EAC, Marine).
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • Control Circuit Voltage Limits : 20...27 V DC 24 V in operation, 14.5 V DC 24 V drop-out
    • Ui Rated Insulation Voltage : 690 V IEC 60947-6-2, 600 V UL 60947-4-1, 600 V CSA C22.2 No 60947-4-1
    • Uc Control Circuit Voltage : 24 V DC
    • Ue Rated Operational Voltage : 690 V AC
    • Uimp Rated Impulse Withstand Voltage : 6 kV IEC 60947-6-2
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Device Application : motor control, motor protection
    • Fire Resistance : 960 °C parts supporting live components IEC 60695-2-12, 650 °C IEC 60695-2-12
    • Function Available : protection against overload and short-circuit, earth fault protection, manual reset, protection against phase failure and phase imbalance
    • Heat Dissipation : 3-3 W control circuit with LUB32, 3-3 W control circuit with LUB38
    • Operating Time : 70 ms closing with LUB38 control circuit35 ms opening with LUB32 control circuit, 35 ms opening with LUB38 control circuit, 70 ms closing with LUB32 control circuit
    • Product Or Component Type : advanced control unit
    • Protective Treatment : TH IEC 60068
    • Range : TeSys
    • Reset : manual reset
    • Resistance To Electrostatic Discharge : 8 kV 3 in open air IEC 61000-4-2, 8 kV 4 on contact IEC 61000-4-2
    • Resistance To Fast Transients : 2 kV 3 serial link IEC 61000-4-4, 4 kV 4 all circuits except for serial link IEC 61000-4-4
    • Safe Separation Of Circuit : 400 V SELV between the control and auxiliary circuits IEC 60947-1, 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
    • Shock Resistance : 10 gn power poles open IEC 60068-2-27, 15 gn power poles closed IEC 60068-2-27
    • Thermal Overload Class : class 10 40-60 Hz -25-55 °C IEC 60947-6-2, class 10 40-60 Hz -25-55 °C UL 508
    • Typical Current Consumption : 80 mA 24 V DC I rms sealed with LUB38, 220 mA 24 V DC I maximum while closing with LUB32, 220 mA 24 V DC I maximum while closing with LUB38, 80 mA 24 V DC I rms sealed with LUB32
    • Utilisation Category : AC-41, AC-43, AC-44
    • Vibration Resistance : 2 gn 5-300 Hz power poles open IEC 60068-2-6, 4 gn 5-300 Hz power poles closed IEC 60068-2-6
    • Carbon Footprint Of The Distribution Phase A4 : 0.06517808668519529, 0.1 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.29829856669211624, 0.3 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0 kg CO2 eq., 0.009253136334203872
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 1 kg CO2 eq., 1.1387113381577099
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 15 kg CO2 eq., 15.363831583386546
    • Certificate Agency : CE, UL, CSA, CCC, EAC, ASEFA, ATEX, Marine
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-05-02
    • Return Indicator : N
    • Stocking Flag : Y
    • Stock Policy : 2
    • Device Type : Relay, Control & Measurement - measuring, monitoring device
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : PPIBS
    • Average Life Duration : 15 year(s)
    • Weee Applicability : Finished product
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2406038EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 1927
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • China Rohs Label : 7
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 2
    • Tier : 2
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Compatibility Code : LUCC
    • Device Short Name : LUCC
    • Energy Efficiency Optimized : False
    • Fixing Mode : plug-in (front face)
    • Halogen Free Status : Halogen free plastic parts product
    • Immunity To Microbreaks : 3 ms
    • Immunity To Radioelectric Fields : 10 V IEC 61000-4-6
    • Immunity To Voltage Dips : 70 % / 500 ms IEC 61000-4-11
    • Load Type : single-phase motor
    • Motor Power Kw : 7.5 kW 400...440 V AC 50/60 Hz 1 phase
    • Network Frequency : 40...60 Hz
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Name : TeSys Ultra
    • Product Specific Application : basic protection and advanced functions, communication
    • Range Of Product : TeSys Ultra
    • Resistance To Radiated Fields : 10 V/m 3 IEC 61000-4-3
    • Returnability : No
    • Software Version : v6.1
    • Sustainable Packaging : Yes
    • Thermal Protection Adjustment Range : 8-32 A
    • Total Lifecycle Carbon Footprint : 17 kg CO2 eq.
    • Tripping Threshold : 14.2 x Ir +/- 20 %
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Warranty In Months : 18
    • R Thermal Protection Adj Range : 8-32 A
    • Control Circuit Voltage 3 Control Circuit Voltage : 24 V
    • Pep Code : ENVPEP2406038EN
    • Database Version : 2023-02
    • Pep Verification Date : 2024-06-01
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
    • Data Source : extrapolated product
    • Functional-unit Description : Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unit
    • Reference Lifetime, In Y : 20
    • Energy Consumption On Product Lifetime, In Kwh : 229.95
    • Energy Model - Manufacturing [A1-a3] : France, FR
    • Energy Model - Installation [A5] : Electricity Mix; Low voltage; 2018; France, FR
    • Energy Model - Use [B6] : Electricity Mix; Low voltage; 2018; France, FR
    • Energy Model - End Of Life [C1-c4] : Electricity Mix; Low voltage; 2018; France, FR
    • Recyclability Potential, In % : 56
    • Height Nominal : 66 mm
    • Width Nominal : 45 mm
  • Environment Attributes Main
    • Ambient Air Temperature For Storage : -40-85 °C, -40-85 °C
    • Ip Degree Of Protection : IP20 front panel and wired terminals IEC 60947-1, IP20 other faces IEC 60947-1, IP40 front panel outside connection zone IEC 60947-1
    • Product Compatibility : power base LUB32, power base LUB38, power base LUB320, power base LUB380, reversing contactor breaker LU2B32BL, reversing contactor breaker LU2B38BL
    • Take Back : No
    • Halogene Performance : Halogen free plastic parts product
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 16.875272711255768
    • Ambient Air Temperature For Operation : -25-70 °C-25-70 °C
    • Circularity Profile : ENVEOLI2406038EN
    • Environmental Disclosure : ENVPEP2406038EN
    • Eu Rohs Directive : Compliant By Exemption
    • Halogen Content Performance : Halogen free plastic parts product
    • Operating Altitude : 6561.68 ft (2000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2406038EN
    • Pep Verification Date : 2024-06-01
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : advanced control unit
    • Range Of Product : TeSys Ultra
  • ETIM
    • ETIM 8 : EC000617
    • ETIM 9 : EC000617
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Country of Origin : Brazil
    • Depth : 60 mm