SQUARE D

Advanced control unit, TeSys Ultra, 3A to 12A, 3P motors, protection & diagnostic, class 20, coil 110-240VAC/DC

ADV.CNTRL.UNIT-CL20-3PH 3-12A

SQDLUCD12FU LUCD12FU 3389110365054
198.65 / EA
http://schema.org/OutOfStock
  • Country of Origin: France
  • Depth: 2.36 in
  • Height: 2.6 in
  • Warranty Length: 18 mth
  • Width: 1.77 in
TeSys U control and diagnostic unit to be inserted in advanced power bases LUB120, LUB320, LUB380 to form a TeSys U starter controller, for 3-phase motor applications up to 5.5kW@400V. It provides full protection to motors with a rated current Ir 3-12A (
QTY
  • Product Description
  • Features
  • Specifications
TeSys U control and diagnostic unit to be inserted in advanced power bases LUB120, LUB320, LUB380 to form a TeSys U starter controller, for 3-phase motor applications up to 5.5kW@400V. It provides full protection to motors with a rated current Ir 3-12A (
  • Uc Control Circuit Voltage
    • 110...240 V AC
    • 110...220 V DC
  • Heat Dissipation
    • 2-2 W control circuit with LUB12
    • 3-3 W control circuit with LUB32
    • 3-3 W control circuit with LUB38
    • 3-3 W control circuit w
  • Load Type
    • 3-phase motor self-cooled
  • Tripping Threshold
    • 14.2 x Ir +/- 20 %
  • Uimp Rated Impulse Withstand Voltage
    • 6 kV IEC 60947-6-2
  • Function Available
    • protection against phase failure and phase imbalance
    • manual reset
    • earth fault protection
    • protection against overload and short-circuit
  • Resistance To Radiated Fields
    • 10 V/m 3 IEC 61000-4-3
  • Typical Current Consumption
    • 280 mA 110...240 V AC I maximum while closing with LUB12
    • 280 mA 110...240 V AC I ma
  • Immunity To Voltage Dips
    • 70 % / 500 ms IEC 61000-4-11
  • Communication
    • LUFC00
    • LULC033
    • LULC15
  • Carbon Footprint Of The Installation Phase A5
    • 0.009556517853358096
    • 0 kg CO2 eq.
  • Carbon Footprint Of The End Of Life Phase C1 To C4
    • 0.3 kg CO2 eq.
    • 0.3080788475672676
  • Standards
    • EN 60947-6-2
    • IEC 60947-6-2
    • UL 60947-4-1, with phase barrier
    • CSA C22.2 No 60947-4-1, with phase barrier
  • Ue Rated Operational Voltage
    • 690 V AC
  • Ui Rated Insulation Voltage
    • 690 V IEC 60947-6-2
    • 600 V UL 60947-4-1
    • 600 V CSA C22.2 No 60947-4-1
  • Operating Time
    • 35 ms opening with LUB12 control circuit
    • 35 ms opening with LUB32 control circuit
    • 35 ms op
  • Ip Degree Of Protection
    • IP20 front panel and wired terminals IEC 60947-1
    • IP20 other faces IEC 60947-1
    • IP40 front panel out
  • Carbon Footprint Of The Manufacturing Phase A1 To A3
    • 1 kg CO2 eq.
    • 1.1760461361300938
  • Protective Treatment
    • TH IEC 60068
  • Device Application
    • motor control
    • motor protection
  • Fixing Mode
    • plug-in (front face)
  • Vibration Resistance
    • 2 gn 5-300 Hz power poles open IEC 60068-2-6
    • 4 gn 5-300 Hz power poles closed IEC 60068-2-6
    • 4 gn 5-300 Hz power poles c
  • Immunity To Radioelectric Fields
    • 10 V IEC 61000-4-6
  • Thermal Overload Class
    • class 20 40-60 Hz -25-70 °C IEC 60947-6-2
    • class 20 40-60 Hz -25-70 °C UL 508
    • class 20 40-60 H
  • Fire Resistance
    • 960 °C parts supporting live components IEC 60695-2-12
    • 650 °C IEC 60695-2-12
  • Carbon Footprint Of The Use Phase B2 B3 B4 B6
    • 15 kg CO2 eq.
    • 14.924864966718356
  • Resistance To Fast Transients
    • 2 kV 3 serial link IEC 61000-4-4
    • 4 kV 4 all circuits except for serial link IEC 61000-4-4
    • 4 kV 4 a
  • Auxiliaries
    • LUA1C20
    • LUA1C11
    • LUFN20
    • LUFN11
    • LUFN02
  • Resistance To Electrostatic Discharge
    • 8 kV 3 in open air IEC 61000-4-2
    • 8 kV 4 on contact IEC 61000-4-2
    • 8 kV 4 on contact IEC 6100
  • Carbon Footprint Of The Distribution Phase A4
    • 0.06731507313389022
    • 0.1 kg CO2 eq.
  • Motor Power Kw
    • 5.5 kW 400...440 V AC 50/60 Hz
    • 5.5 kW 500 V AC 50/60 Hz
    • 9 kW 690 V AC 50/60 Hz
    • 9 kW 69
  • Non Dissipating Shock Wave
    • 1 kV serial mode IEC 60947-6-2
    • 2 kV common mode IEC 60947-6-2
  • Control Circuit Voltage Limits
    • 88...264 V AC 110...240 V in operation
    • 88...242 V DC 110...220 V in operation
    • 88...242 V DC 110...
  • Utilisation Category
    • AC-44
    • AC-41
    • AC-43
  • Safe Separation Of Circuit
    • 400 V SELV between the control and auxiliary circuits IEC 60947-1
    • 400 V SELV between the control or auxiliary circuit and
  • Shock Resistance
    • 10 gn power poles open IEC 60068-2-27
    • 15 gn power poles closed IEC 60068-2-27
  • Product Compatibility
    • power base LUB12
    • power base LUB32
    • power base LUB38
    • power base LUB120
    • power base LUB320
    • power base LUB380
    • reversing contactor breaker LU2B12FU
    • reversi
  • Product Certifications
    • CE
    • UL
    • CSA
    • CCC
    • EAC
    • ASEFA
    • ATEX
    • Marine
  • Important Information Attributes
    • Country Id : US
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-08-13
    • ETIM 10 : EC000617
    • Device Type : Relay, Control & Measurement - measuring, monitoring device
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : PPIBS
    • Average Life Duration : 15 year(s)
    • Manufacturing Carbon Footprint : 1.17604613613009
    • Distribution Carbon Footprint : 6.73150731338902e-02
    • Installation Carbon Footprint : 9.5565178533581e-03
    • Use Carbon Footprint : 14.9248649667184
    • End Of Life Carbon Footprint : 0.308078847567268
    • WEEE Applicability : Component
    • WEEE Scope : In
    • Legacy WEEE Scope : In
    • WEEE Product Category : 5
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2406038EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS Eur In Scope : Yes
    • ROHS Eur Status : Compliant with Exemptions
    • ROHS Eur Conformity Date : 1927
    • ROHS Eur Full Compliance Status : Compliant with Exemptions
    • ROHS Eur Full Compliance Status Id : COMPLIANT_WITH_EXEMPTIONS
    • China ROHS In Scope : No
    • China ROHS Label : 6
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • WD Status : 1 - GSC certified
    • Compatibility Code : LUCD
    • Device Short Name : LUCD
    • Energy Efficiency Optimized : False
    • Halogen Free Status : Halogen free plastic parts product
    • Immunity To Microbreaks : 3 ms
    • Network Frequency : 40...60 Hz
    • Package Weight Lbs : 126.0 g
    • Phase Failure Sensitivity : yes
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : advanced control unit
    • Product Specific Application : basic protection and advanced functions, communication
    • Range : TeSys
    • Range Of Product : TeSys Ultra
    • Reset : manual reset
    • Returnability : Yes
    • Sustainable Packaging : Yes
    • Thermal Protection Adjustment Range : 3-12 A
    • Total Lifecycle Carbon Footprint : 16 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Carbon Footprint Kg Co2 Eq Total Life Cycle : 16.485861541402965
    • Relationshiptype : Compatible relationship
  • General Attributes
    • Product Or Component Type : advanced control unit
    • Range Of Product : TeSys Ultra
  • Environment Attributes
    • ROHS Exemption Information : Yes
    • China ROHS Url : https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=exportPdfRoHSChina&pid=640802&lang=en-us
    • Take Back : No
    • Halogene Performance : Halogen free plastic parts product
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Mercury Free : Yes
    • Carbon Footprint : 16.485861541403
    • Ambient Air Temperature For Operation : -25-70 °C
    • Ambient Air Temperature For Storage : -40-85 °C
    • Circularity Profile : ENVEOLI2406038EN
    • Environmental Disclosure : ENVPEP2406038EN
    • Eu Rohs Directive : Compliant with Exemptions
    • Halogen Content Performance : Halogen free plastic parts product
    • Operating Altitude : 6561.68 ft (2000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Country of Origin : France
    • Height : 2.6 in
    • Width : 1.77 in
    • Depth : 2.36 in