All in one, Homeline, CSED, ringed socket, 200A, surface mount, 42 spaces, 42 circuits, 22kA SCCR, no bypass, solar ready

All in one, Homeline, CSED, ringed socket, 200A, surface mount, 42 spaces, 42 circuits, 22kA SCCR, no bypass, solar ready

SQDSC42M200PS SC42M200PS 785901176152
304.19 / EA
http://schema.org/OutOfStock
  • Depth: 6.30 in
  • Number of Spaces: 42, 42
The Square D® Homeline® Load Centers and Homeline Solar Ready PoN CSEDs, SC42M200PS, provides metered service and a main circuit breaker and 42 circuits. All-In-Ones are UL Listed, suitable only for use as service equipment. This device meets EUSERC standarts, Federal Specification W-P-115c as Type 1, Class 2. Suitable for OH service with addition of tunnel kit (SCTKP20). This Homeline load center has a two pole GFCI circuit breaker that is rated at 50A 120/240 VAC single phase. Homeline load center provides a 10 kA breaking capacity. This system provides 2 spaces in a NEMA 3R rain proof enclosure. The electrical connections are box lugs. The box lugs will accept a wire range of 8 AWG to 6 AWG copper or aluminum wire. This Homeline load center has a height of 9.37 inches, a width of 4.88 inches, and depth of 4.01 inches. CHOM Homeline load centers are CSA certified.
QTY
  • Product Description
  • Features
  • Specifications
The Square D® Homeline® Load Centers and Homeline Solar Ready PoN CSEDs, SC42M200PS, provides metered service and a main circuit breaker and 42 circuits. All-In-Ones are UL Listed, suitable only for use as service equipment. This device meets EUSERC standarts, Federal Specification W-P-115c as Type 1, Class 2. Suitable for OH service with addition of tunnel kit (SCTKP20). This Homeline load center has a two pole GFCI circuit breaker that is rated at 50A 120/240 VAC single phase. Homeline load center provides a 10 kA breaking capacity. This system provides 2 spaces in a NEMA 3R rain proof enclosure. The electrical connections are box lugs. The box lugs will accept a wire range of 8 AWG to 6 AWG copper or aluminum wire. This Homeline load center has a height of 9.37 inches, a width of 4.88 inches, and depth of 4.01 inches. CHOM Homeline load centers are CSA certified.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Physical Attributes
    • Color Of Enclosure : grey
  • Complementary Attributes
    • Branch Circuit Breaker Rated Current : 200 A
    • Bus Rated Current : 225.0 A
    • Line Rated Current : 200 A
    • Service Disconnect Rated Current : 200 A
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, SC
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, Electrician
    • Awg Gauge : AWG 4...250 kcmil (aluminium/copper) line side, AWG 14...AWG 2/0 (aluminium/copper) service ground
    • Electrical Connection : lugs, line side, lugs, service ground
    • Number Of Spaces : 42, 42
    • Service Feed Location : OH, UG
    • Tightening Torque : main lugs 250 lb.in, AWG 4...250 kcmil, aluminium/copper, service ground 50 lb.in, AWG 14...AWG 2/0, copper, service ground 50 lb.in, AWG 12...AWG 2/0, aluminium, branch lugs 50 lb.in, AWG 14...AWG 4, copper, branch lugs 50 lb.in, AWG 12...AWG 2, aluminium, branch lugs 35 lb.in, AWG 6...AWG 4, aluminium/copper, branch lugs 25 lb.in, AWG 8, aluminium/copper, branch lugs 20 lb.in, AWG 14...AWG 10, aluminium/copper, branch lugs 20 lb.in, AWG 12...AWG 10, aluminium/copper, Cover 10 lb.in
    • Carbon Footprint Of The Distribution Phase A4 : 19.114063002439536, 19 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 45 kg CO2 eq., 44.613423554591954
    • Carbon Footprint Of The Installation Phase A5 : 0.37333269237076094, 0.4 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 178 kg CO2 eq., 178.20366636195504
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 20 kg CO2 eq., 19.79338009122855
    • Medium Desc : All in one, Homeline, CSED, ringed socket, 200A, surface mount, 42 spaces, 42 circuits, 22kA SCCR, no bypass, solar ready
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-12-09
    • Global Commercial Status : Commercialised
    • Return Indicator : Y
    • Stocking Flag : N
    • H And D Domain : Safety
    • H And D Subrange : RESI
    • H And D Enrichment Assignment : no
    • H And D Enrichment Function : ENCLOSURES
    • H And D Enrichment Class 3 : Meter enclosures
    • H And D Enrichment Class 4 : Combination service entrance device
    • Legacy Weee Scope : In
    • Scope Perimeter : Outside of Europe
    • Eoli Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : No
    • With Recycled Cardboard : No
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Market Segmentation Id : RESIDENTIAL
    • Market Segmentation : Residential
    • Product Kit Identifier : N
    • Energy Efficiency Optimized : False
    • Hub Type : A
    • Meter Socket Type : ringed
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : All-In-One
    • Range Of Product : Homeline
    • Returnability : Yes
    • Short Circuit Current : 22 kA
    • Software Version : v6.2.5-6
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 262 kg CO2 eq.
    • Color Of Enclosure : grey
    • Connections Terminals : plug-on neutral
    • Pep Code : ENVPEP2509019EN
    • Database Version : 2024-01
    • Pep Verification Date : 2025-09-01
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional Unit Description : When a product covered by this PSR includes additional functions, the functional unit defined in the PSR shall be used and shall be completed in order to take into account these additional functionsThe installation must be protected against overloads and short circuits in accordance with the circuit’s rated voltage (Ue), rated current (In), number of poles (Np), rated breaking capacity (Icn), and tripping curve (Cd). The protective device should be capable of establishing, carrying, and interrupting the rated current at the rated voltage. It must be suitable for wall-mounted or enclosure/cabinet installations in household or commercial environments, depending on the intended use. Additionally, the device should be designed to maintain reliable performance throughout a reference service life of 20 years.
    • Functional Unit Unit : unit
    • Energy Model Manufacturing A1 A3 2 : Electricity Mix; Low voltage; 2020; Mexico, MX
    • Energy Model Installation A5 2 : No energy used
    • Energy Model Use B6 2 : Electricity Mix; Low voltage; 2020; United States, US
    • Energy Model End Of Life C1 C4 2 : Global, European and French datasets are used.
    • Height Nominal : 37.30 in
    • Width Nominal : 21.50 in
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    • Take Back : Nej
    • Recycled Metal Content At Cr Level : 0 %
    • Mercury Free : Yes
    • Carbon Footprint : 262.09786570258586
    • Environmental Disclosure : ENVPEP2509019EN
    • Eu Rohs Directive : Compliant By Exemption
    • Nema Degree Of Protection : NEMA 3R
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : No
    • Product Compatibility : solar ready
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2509019EN
    • Pep Verification Date : 2025-09-01
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : All-In-One
    • Range Of Product : Homeline
  • Output Attributes
    • Bypass Type : no bypass
  • Specifications
    • Depth : 6.30 in