Contactor, Type L, multipole lighting, mechanically held, 30A, 8 pole, 600V, 110/120VAC 50/60Hz coil, NEMA 1, +option [TAA]

LIGHTING CONTACTOR 600VAC 30A

SQD8903LXG80V02R6 8903LXG80V02R6 785901023388
1744.89 / EACH
http://schema.org/OutOfStock
  • Country of Origin: Mexico
  • Warranty Length: 18 mth
8903L/LX multipole lighting contactors are for lighting control applications. 8903L/LX lighting contactors are available in either mechanically held or electrically held versions. This is a mechanically held device. Contacts can switch up to 30A fluorescent and 20A tungsten lighting loads. The contacts are field convertible from NO to NC. This 8 pole device has 8 NO contacts. Replacement contact kits are available for this lighting contactor. Interchangeable coil is available in a wide variety of common voltages up to 600VAC. This unit is supplied with 110/120VAC 50/60Hz interchangeable operating coil but other coils are available in a wide variety of common voltages up to 600VAC. Coil and contacts are easily replaced. Contactor is in a NEMA 1 enclosure, but a variety of other enclosure types are available. A wide variety of accessories are available for Type L/LX lighting contactors. This lighting contactor is supplied with a two-wire interface. 8903L/LX lighting contactors are UL Listed and CSA Certified.
QTY
  • Product Description
  • Features
  • Specifications
8903L/LX multipole lighting contactors are for lighting control applications. 8903L/LX lighting contactors are available in either mechanically held or electrically held versions. This is a mechanically held device. Contacts can switch up to 30A fluorescent and 20A tungsten lighting loads. The contacts are field convertible from NO to NC. This 8 pole device has 8 NO contacts. Replacement contact kits are available for this lighting contactor. Interchangeable coil is available in a wide variety of common voltages up to 600VAC. This unit is supplied with 110/120VAC 50/60Hz interchangeable operating coil but other coils are available in a wide variety of common voltages up to 600VAC. Coil and contacts are easily replaced. Contactor is in a NEMA 1 enclosure, but a variety of other enclosure types are available. A wide variety of accessories are available for Type L/LX lighting contactors. This lighting contactor is supplied with a two-wire interface. 8903L/LX lighting contactors are UL Listed and CSA Certified.
  • Inrush Power In VA
    • 25-25 VA 60 Hz
    • 180-180 VA 50 Hz
    • 170-170 VA 50/60 Hz
  • CAD
    • https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003049_3D-CAD&p_File_name=MCADPP0003049_3D-simplified-ec.stp
    • https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003049_3D-CAD&p_File_name=MCADPP0003049_2D-back.dwg
    • https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003049_3D-CAD&p_File_name=MCADPP0003049_2D-back.dxf
    • https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003049_3D-CAD&p_File_name=MCADPP0003049_2D-bottom.dwg
    • https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003049_3D-CAD&p_File_name=MCADPP0003049_2D-bottom.dxf
    • https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003049_3D-CAD&p_File_name=MCADPP0003049_2D-front.dwg
    • https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003049_3D-CAD&p_File_name=MCADPP0003049_2D-front.dxf
    • https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003049_3D-CAD&p_File_name=MCADPP0003049_2D-isometric.dwg
    • https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003049_3D-CAD&p_File_name=MCADPP0003049_2D-isometric.dxf
    • https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003049_3D-CAD&p_File_name=MCADPP0003049_2D-left.dwg
    • https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003049_3D-CAD&p_File_name=MCADPP0003049_2D-left.dxf
    • https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003049_3D-CAD&p_File_name=MCADPP0003049_2D-right.dwg
    • https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003049_3D-CAD&p_File_name=MCADPP0003049_2D-right.dxf
    • https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003049_3D-CAD&p_File_name=MCADPP0003049_2D-top.dwg
    • https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003049_3D-CAD&p_File_name=MCADPP0003049_2D-top.dxf
  • Prop 65
    • WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
  • Carbon Footprint Of The Installation Phase A5
    • 0.7199933933015371
    • 0.7 kg CO2 eq.
  • Carbon Footprint Of The End Of Life Phase C1 To C4
    • 7 kg CO2 eq.
    • 7.467300060215353
  • UC Control Circuit Voltage
    • 110 V AC 50 Hz
    • 120 V AC 60 Hz
  • Carbon Footprint Of The Manufacturing Phase A1 To A3
    • 40 kg CO2 eq.
    • 40.3364976803852
  • Nema Degree Of Protection
    • NEMA 1 painted sheet steel surface
  • Accessories
    • 8903L3L
    • 8903L3R
    • 9999SP28R
    • 9999SPL28G
    • 9999SPL28R
    • 9001KA2
    • 9999SC2
    • 9999BLX
    • 9001KN260
  • Market Segmentation
    • Commercial
    • Industrial
  • Persona Type Names
    • End User
    • Contractor
    • Original Equipment Manufacturer
    • OEM - Control Panelbuilder
    • Panel Builder
    • Electrician
  • Carbon Footprint Of The Use Phase B2 B3 B4 B6
    • 276 kg CO2 eq.
    • 276.35638917539256
  • Line Rated Current
    • 20-20 A tungsten
    • 30-30 A fluorescent
  • Persona Type Ids
    • EU
    • LC
    • OM
    • OM8
    • PB
    • SC
  • Carbon Footprint Of The Distribution Phase A4
    • 4.398293336819173
    • 4 kg CO2 eq.
  • Poles Description
    • 8P 8 NO
  • Market Segmentation Id
    • COMMERCIAL
    • INDUSTRIAL
  • Important Information Attributes
    • B2B Bullet Point 1 : Multi-pole design for efficient lighting control.
    • B2B Bullet Point 2 : Available in a wide range of enclosures to suit various applications.
    • B2B Bullet Point 3 : Silver-Cadmium-Oxide double break contacts.
    • B2B Bullet Point 4 : Field-convertible contacts with N.O. and N.C. indicators.
    • B2B Bullet Point 5 : This product is TAA compliant.
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-11-18
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Manufacturing Carbon Footprint : 40.3364976803852
    • Distribution Carbon Footprint : 4.398293336819173
    • Installation Carbon Footprint : 0.7199933933015371
    • Use Carbon Footprint : 276.35638917539256
    • End Of Life Carbon Footprint : 7.467300060215353
    • Legacy WEEE Scope : In
    • WEEE Product Category : 5
    • Scope Perimeter : Outside of Europe
    • EOLI Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant
    • ROHS EUR Conformity Date : 1926
    • ROHS EUR Full Compliance Status : Compliant
    • ROHS EUR Full Compliance Status Id : COMPLIANT
    • China ROHS In Scope : No
    • China ROHS Label : 1
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : N
    • WD Status : A - SELECTED - PCE ONLY (Migration)
    • Tier Id : 2
    • Tier : 2
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Additional Included Device : 2P relay (1 NO + 1 NC)
    • Control Type : no control units
    • Energy Efficiency Optimized : False
    • Halogen Free Status : Halogen free plastic parts product
    • Local Signalling : no indicator
    • Package Weight Lbs : 5.298 kg
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : Mechanically Held Lighting Contactor
    • Range Of Product : 8903LX
    • Returnability : No
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 329 kg CO2 eq.
    • Carbon Footprint Kg Co2 Eq Total Life Cycle : 329.2784736461138
    • Relationship Type : Compatible relationship
    • Pep Code : ENVPEP1407018EN
    • Pep Verification Date : 2025-10-15
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
    • Product Weight In G : 5298
    • Functional Unit Description : Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
    • Functional Unit Quantity : 1
    • Functional Unit Unit : unit
    • Reference Lifetime In Y : 20
    • Energy Consumption On Product Lifetime In Kwh : 644.736
    • Recyclability Potential In : 90
    • Nbr Of Units In Pkg : 1
    • Warranty In Months : 18
    • Energy Model Manufacturing A1 A3 : Electricity Mix; Low voltage; 2020; United States, US
    • Energy Model Installation A5 : No energy used
    • Energy Model Use B6 : Electricity Mix; Low voltage; 2020; United States, US
    • Energy Model End Of Life C1 C4 : Global, European and French datasets are used.
    • Acidification Ap Mole Of H Equiv Total Life Cycle : 1.5379072730204244
    • Acidification Ap Mole Of H Equiv Manufacturing A1 A3 : 0.24985549970061757
    • Acidification Ap Mole Of H Equiv Distribution A4 : 0.019352069815958346
    • Acidification Ap Mole Of H Equiv Installation A5 : 0.0007318729753194219
    • Acidification Ap Mole Of H Equiv Maintenance B2 : 0
    • Acidification Ap Mole Of H Equiv Repair B3 : 0
    • Acidification Ap Mole Of H Equiv Replacement B4 : 0
    • Acidification Ap Mole Of H Equiv Operational Energy Use B6 : 1.230750497334226
    • Acidification Ap Mole Of H Equiv End Of Life C1 C4 : 0.03721733319430306
    • Acidification Ap Mole Of H Equiv Benefits Loads Beyond System Boundaries D : -0.12410158689238443
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Total Life Cycle : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Manufacturing A1 A3 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Distribution A4 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Installation A5 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Maintenance B2 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Repair B3 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Replacement B4 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Operational Energy Use B6 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C End Of Life C1 C4 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Benefits Loads Beyond System Boundaries D : 0
    • Biogenic Carbon Content Of The Product Kg Of C Total Life Cycle : 0
    • Biogenic Carbon Content Of The Product Kg Of C Manufacturing A1 A3 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Distribution A4 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Installation A5 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Maintenance B2 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Repair B3 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Replacement B4 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Operational Energy Use B6 : 0
    • Biogenic Carbon Content Of The Product Kg Of C End Of Life C1 C4 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Benefits Loads Beyond System Boundaries D : 0
    • Climate Change Biogenics Kg Co2 Eq Total Life Cycle : 1.8378438925541296
    • Climate Change Biogenics Kg Co2 Eq Manufacturing A1 A3 : -0.12638449744695635
    • Climate Change Biogenics Kg Co2 Eq Distribution A4 : 0
    • Climate Change Biogenics Kg Co2 Eq Installation A5 : 0.5526064305085778
    • Climate Change Biogenics Kg Co2 Eq Maintenance B2 : 0
    • Climate Change Biogenics Kg Co2 Eq Repair B3 : 0
    • Climate Change Biogenics Kg Co2 Eq Replacement B4 : 0
    • Climate Change Biogenics Kg Co2 Eq Operational Energy Use B6 : 1.3827972000204216
    • Climate Change Biogenics Kg Co2 Eq End Of Life C1 C4 : 0.02882475947208642
    • Climate Change Biogenics Kg Co2 Eq Benefits Loads Beyond System Boundaries D : -0.06892365934997204
    • Climate Change Fossil Fuels Kg Co2 Eq Total Life Cycle : 327.44062714529207
    • Climate Change Fossil Fuels Kg Co2 Eq Manufacturing A1 A3 : 40.46288184380103
    • Climate Change Fossil Fuels Kg Co2 Eq Distribution A4 : 4.398293336819173
    • Climate Change Fossil Fuels Kg Co2 Eq Installation A5 : 0.16738696160021685
    • Climate Change Fossil Fuels Kg Co2 Eq Maintenance B2 : 0
    • Climate Change Fossil Fuels Kg Co2 Eq Repair B3 : 0
    • Climate Change Fossil Fuels Kg Co2 Eq Replacement B4 : 0
    • Climate Change Fossil Fuels Kg Co2 Eq Operational Energy Use B6 : 274.97359197537213
    • Climate Change Fossil Fuels Kg Co2 Eq End Of Life C1 C4 : 7.438473027699516
    • Climate Change Fossil Fuels Kg Co2 Eq Benefits Loads Beyond System Boundaries D : -17.057195729797833
    • Climate Change Total Kg Co2 Eq Total Life Cycle : 329.2784736461138
    • Climate Change Total Kg Co2 Eq Manufacturing A1 A3 : 40.3364976803852
    • Climate Change Total Kg Co2 Eq Distribution A4 : 4.398293336819173
    • Climate Change Total Kg Co2 Eq Installation A5 : 0.7199933933015371
    • Climate Change Total Kg Co2 Eq Maintenance B2 : 0
    • Climate Change Total Kg Co2 Eq Repair B3 : 0
    • Climate Change Total Kg Co2 Eq Replacement B4 : 0
    • Climate Change Total Kg Co2 Eq Operational Energy Use B6 : 276.35638917539256
    • Climate Change Total Kg Co2 Eq End Of Life C1 C4 : 7.467300060215353
    • Climate Change Total Kg Co2 Eq Benefits Loads Beyond System Boundaries D : -17.126119389147807
    • Components For Re Use Kg Total Life Cycle : 0
    • Components For Re Use Kg Manufacturing A1 A3 : 0
    • Components For Re Use Kg Distribution A4 : 0
    • Components For Re Use Kg Installation A5 : 0
    • Components For Re Use Kg Maintenance B2 : 0
    • Components For Re Use Kg Repair B3 : 0
    • Components For Re Use Kg Replacement B4 : 0
    • Components For Re Use Kg Operational Energy Use B6 : 0
    • Components For Re Use Kg End Of Life C1 C4 : 0
    • Components For Re Use Kg Benefits Loads Beyond System Boundaries D : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Total Life Cycle : 0.014315022601858064
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Manufacturing A1 A3 : 0.014255989799190887
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Distribution A4 : 0.00000000037887274221
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Installation A5 : 0.00000001726696042741
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Maintenance B2 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Repair B3 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Replacement B4 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Operational Energy Use B6 : 0.00005852489327578678
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb End Of Life C1 C4 : 0.00000049026355821839
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Benefits Loads Beyond System Boundaries D : -0.0053087334348444785
    • Depletion Of Abiotic Resources Fossil Fuels Mj Total Life Cycle : 7090.702172929117
    • Depletion Of Abiotic Resources Fossil Fuels Mj Manufacturing A1 A3 : 891.6280090081743
    • Depletion Of Abiotic Resources Fossil Fuels Mj Distribution A4 : 54.84271111314786
    • Depletion Of Abiotic Resources Fossil Fuels Mj Installation A5 : 2.2346749077145596
    • Depletion Of Abiotic Resources Fossil Fuels Mj Maintenance B2 : 0
    • Depletion Of Abiotic Resources Fossil Fuels Mj Repair B3 : 0
    • Depletion Of Abiotic Resources Fossil Fuels Mj Replacement B4 : 0
    • Depletion Of Abiotic Resources Fossil Fuels Mj Operational Energy Use B6 : 6042.751035114941
    • Depletion Of Abiotic Resources Fossil Fuels Mj End Of Life C1 C4 : 99.24574278513953
    • Depletion Of Abiotic Resources Fossil Fuels Mj Benefits Loads Beyond System Boundaries D : -381.71337122219956
    • Ecotoxicity Fresh Water Ctue Total Life Cycle : 771.7933658880274
    • Ecotoxicity Fresh Water Ctue Manufacturing A1 A3 : 337.59362747823
    • Ecotoxicity Fresh Water Ctue Distribution A4 : 35.85171077740982
    • Ecotoxicity Fresh Water Ctue Installation A5 : 2.974577082218292
    • Ecotoxicity Fresh Water Ctue Maintenance B2 : 0
    • Ecotoxicity Fresh Water Ctue Repair B3 : 0
    • Ecotoxicity Fresh Water Ctue Replacement B4 : 0
    • Ecotoxicity Fresh Water Ctue Operational Energy Use B6 : 343.27930868811376
    • Ecotoxicity Fresh Water Ctue End Of Life C1 C4 : 52.09414186205548
    • Ecotoxicity Fresh Water Ctue Benefits Loads Beyond System Boundaries D : -54.993974469171896
    • Emission Of Fine Particles Incidence Of Diseases Total Life Cycle : 0.0000167126528849391
    • Emission Of Fine Particles Incidence Of Diseases Manufacturing A1 A3 : 0.00000738021026226564
    • Emission Of Fine Particles Incidence Of Diseases Distribution A4 : 0.00000005239636266987
    • Emission Of Fine Particles Incidence Of Diseases Installation A5 : 0.00000000509965285588
    • Emission Of Fine Particles Incidence Of Diseases Maintenance B2 : 0
    • Emission Of Fine Particles Incidence Of Diseases Repair B3 : 0
    • Emission Of Fine Particles Incidence Of Diseases Replacement B4 : 0
    • Emission Of Fine Particles Incidence Of Diseases Operational Energy Use B6 : 0.0000090280879632752
    • Emission Of Fine Particles Incidence Of Diseases End Of Life C1 C4 : 0.00000024685864387251
    • Emission Of Fine Particles Incidence Of Diseases Benefits Loads Beyond System Boundaries D : -0.00000886817267925731
    • Exported Energy Mj By Energy Vector Total Life Cycle : 0.050865369913527705
    • Exported Energy Mj By Energy Vector Manufacturing A1 A3 : 0.006597479363478401
    • Exported Energy Mj By Energy Vector Distribution A4 : 0
    • Exported Energy Mj By Energy Vector Installation A5 : 0
    • Exported Energy Mj By Energy Vector Maintenance B2 : 0
    • Exported Energy Mj By Energy Vector Repair B3 : 0
    • Exported Energy Mj By Energy Vector Replacement B4 : 0
    • Exported Energy Mj By Energy Vector Operational Energy Use B6 : 0
    • Exported Energy Mj By Energy Vector End Of Life C1 C4 : 0.0442678905500493
    • Exported Energy Mj By Energy Vector Benefits Loads Beyond System Boundaries D : 0
    • Freshwater Eutrophication Kg P Eq Total Life Cycle : 0.000560225525899497
    • Freshwater Eutrophication Kg P Eq Manufacturing A1 A3 : 0.00006630128301762476
    • Freshwater Eutrophication Kg P Eq Distribution A4 : 0.00000051611369789947
    • Freshwater Eutrophication Kg P Eq Installation A5 : 0.00000014210235104896
    • Freshwater Eutrophication Kg P Eq Maintenance B2 : 0
    • Freshwater Eutrophication Kg P Eq Repair B3 : 0
    • Freshwater Eutrophication Kg P Eq Replacement B4 : 0
    • Freshwater Eutrophication Kg P Eq Operational Energy Use B6 : 0.00047449661738922636
    • Freshwater Eutrophication Kg P Eq End Of Life C1 C4 : 0.0000187694094436974
    • Freshwater Eutrophication Kg P Eq Benefits Loads Beyond System Boundaries D : -0.00002889299042851133
    • Hazardous Waste Disposed Of Kg Total Life Cycle : 342.83057799575084
    • Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 342.633731506505
    • Hazardous Waste Disposed Of Kg Distribution A4 : 0.003651773796953225
    • Hazardous Waste Disposed Of Kg Installation A5 : 0.1305840350867463
    • Hazardous Waste Disposed Of Kg Maintenance B2 : 0
    • Hazardous Waste Disposed Of Kg Repair B3 : 0
    • Hazardous Waste Disposed Of Kg Replacement B4 : 0
    • Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 0
    • Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 0.06261068036211494
    • Hazardous Waste Disposed Of Kg Benefits Loads Beyond System Boundaries D : -416.86711705869857
    • Human Toxicity Carcinogenic Effects Ctuh Total Life Cycle : 0.00004243866272066463
    • Human Toxicity Carcinogenic Effects Ctuh Manufacturing A1 A3 : 0.0000424054729763965
    • Human Toxicity Carcinogenic Effects Ctuh Distribution A4 : 0.00000000009128378401
    • Human Toxicity Carcinogenic Effects Ctuh Installation A5 : 0.00000000002184985106
    • Human Toxicity Carcinogenic Effects Ctuh Maintenance B2 : 0
    • Human Toxicity Carcinogenic Effects Ctuh Repair B3 : 0
    • Human Toxicity Carcinogenic Effects Ctuh Replacement B4 : 0
    • Human Toxicity Carcinogenic Effects Ctuh Operational Energy Use B6 : 0.00000003235126475798
    • Human Toxicity Carcinogenic Effects Ctuh End Of Life C1 C4 : 0.00000000072534587508
    • Human Toxicity Carcinogenic Effects Ctuh Benefits Loads Beyond System Boundaries D : -0.00005716390014326503
    • Human Toxicity Non Carcinogenic Effects Ctuh Total Life Cycle : 0.00000219025391963988
    • Human Toxicity Non Carcinogenic Effects Ctuh Manufacturing A1 A3 : 0.0000013336477611968
    • Human Toxicity Non Carcinogenic Effects Ctuh Distribution A4 : 0.00000000675363459833
    • Human Toxicity Non Carcinogenic Effects Ctuh Installation A5 : 0.00000000087475636217
    • Human Toxicity Non Carcinogenic Effects Ctuh Maintenance B2 : 0
    • Human Toxicity Non Carcinogenic Effects Ctuh Repair B3 : 0
    • Human Toxicity Non Carcinogenic Effects Ctuh Replacement B4 : 0
    • Human Toxicity Non Carcinogenic Effects Ctuh Operational Energy Use B6 : 0.00000079989104096228
    • Human Toxicity Non Carcinogenic Effects Ctuh End Of Life C1 C4 : 0.00000004908672652031
    • Human Toxicity Non Carcinogenic Effects Ctuh Benefits Loads Beyond System Boundaries D : -0.00000115263789860308
    • Impacts Related To Land Use Soil Quality Total Life Cycle : 6.246762623651348
    • Impacts Related To Land Use Soil Quality Manufacturing A1 A3 : 0.49449829540478546
    • Impacts Related To Land Use Soil Quality Distribution A4 : 0
    • Impacts Related To Land Use Soil Quality Installation A5 : 0.002578042930570354
    • Impacts Related To Land Use Soil Quality Maintenance B2 : 0
    • Impacts Related To Land Use Soil Quality Repair B3 : 0
    • Impacts Related To Land Use Soil Quality Replacement B4 : 0
    • Impacts Related To Land Use Soil Quality Operational Energy Use B6 : 5.657122366912012
    • Impacts Related To Land Use Soil Quality End Of Life C1 C4 : 0.09256391840397975
    • Impacts Related To Land Use Soil Quality Benefits Loads Beyond System Boundaries D : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Total Life Cycle : 283.97817469974007
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Manufacturing A1 A3 : 23.428436280809297
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Distribution A4 : 0.009772283387493103
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Installation A5 : 0.04410843217949039
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Maintenance B2 : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Repair B3 : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Replacement B4 : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Operational Energy Use B6 : 259.2571649114646
    • Ionizing Radiation Human Health Kbq Of U235 Equiv End Of Life C1 C4 : 1.2386927918991957
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Benefits Loads Beyond System Boundaries D : -3.3250723647099667
    • Marine Aquatic Eutrophication Kg Of N Equiv Total Life Cycle : 0.21415489295068113
    • Marine Aquatic Eutrophication Kg Of N Equiv Manufacturing A1 A3 : 0.042382722014623106
    • Marine Aquatic Eutrophication Kg Of N Equiv Distribution A4 : 0.008908418116381633
    • Marine Aquatic Eutrophication Kg Of N Equiv Installation A5 : 0.0001841645003247725
    • Marine Aquatic Eutrophication Kg Of N Equiv Maintenance B2 : 0
    • Marine Aquatic Eutrophication Kg Of N Equiv Repair B3 : 0
    • Marine Aquatic Eutrophication Kg Of N Equiv Replacement B4 : 0
    • Marine Aquatic Eutrophication Kg Of N Equiv Operational Energy Use B6 : 0.15605814000532997
    • Marine Aquatic Eutrophication Kg Of N Equiv End Of Life C1 C4 : 0.006621448314021633
    • Marine Aquatic Eutrophication Kg Of N Equiv Benefits Loads Beyond System Boundaries D : -0.01001653765327527
    • Materials For Energy Recovery Kg Total Life Cycle : 0
    • Materials For Energy Recovery Kg Manufacturing A1 A3 : 0
    • Materials For Energy Recovery Kg Distribution A4 : 0
    • Materials For Energy Recovery Kg Installation A5 : 0
    • Materials For Energy Recovery Kg Maintenance B2 : 0
    • Materials For Energy Recovery Kg Repair B3 : 0
    • Materials For Energy Recovery Kg Replacement B4 : 0
    • Materials For Energy Recovery Kg Operational Energy Use B6 : 0
    • Materials For Energy Recovery Kg End Of Life C1 C4 : 0
    • Materials For Energy Recovery Kg Benefits Loads Beyond System Boundaries D : 0
    • Materials For Recycling Kg Total Life Cycle : 5.1327789982095915
    • Materials For Recycling Kg Manufacturing A1 A3 : 0.6575520927226349
    • Materials For Recycling Kg Distribution A4 : 0
    • Materials For Recycling Kg Installation A5 : 0
    • Materials For Recycling Kg Maintenance B2 : 0
    • Materials For Recycling Kg Repair B3 : 0
    • Materials For Recycling Kg Replacement B4 : 0
    • Materials For Recycling Kg Operational Energy Use B6 : 0
    • Materials For Recycling Kg End Of Life C1 C4 : 4.475226905486957
    • Materials For Recycling Kg Benefits Loads Beyond System Boundaries D : 0
    • Net Use Of Fresh Water M3 Total Life Cycle : 0.6488545288875408
    • Net Use Of Fresh Water M3 Manufacturing A1 A3 : 0.2446850316151904
    • Net Use Of Fresh Water M3 Distribution A4 : 0.005206497597917851
    • Net Use Of Fresh Water M3 Installation A5 : 0.0002546513563685351
    • Net Use Of Fresh Water M3 Maintenance B2 : 0
    • Net Use Of Fresh Water M3 Repair B3 : 0
    • Net Use Of Fresh Water M3 Replacement B4 : 0
    • Net Use Of Fresh Water M3 Operational Energy Use B6 : 0.36633176785326305
    • Net Use Of Fresh Water M3 End Of Life C1 C4 : 0.032376580464801005
    • Net Use Of Fresh Water M3 Benefits Loads Beyond System Boundaries D : -0.1981558648689983
    • Non Hazardous Waste Disposed Of Kg Total Life Cycle : 76.4138544752874
    • Non Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 26.647950417196245
    • Non Hazardous Waste Disposed Of Kg Distribution A4 : 0.00448616558878711
    • Non Hazardous Waste Disposed Of Kg Installation A5 : 0.03169166617414632
    • Non Hazardous Waste Disposed Of Kg Maintenance B2 : 0
    • Non Hazardous Waste Disposed Of Kg Repair B3 : 0
    • Non Hazardous Waste Disposed Of Kg Replacement B4 : 0
    • Non Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 43.844556111823664
    • Non Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 5.885170114504554
    • Non Hazardous Waste Disposed Of Kg Benefits Loads Beyond System Boundaries D : -13.04396184609447
    • Ozone Depletion Kg Equivalent Cfc 11 Total Life Cycle : 0.00001713172407749287
    • Ozone Depletion Kg Equivalent Cfc 11 Manufacturing A1 A3 : 0.00001196520738499082
    • Ozone Depletion Kg Equivalent Cfc 11 Distribution A4 : 0.00000388958025333858
    • Ozone Depletion Kg Equivalent Cfc 11 Installation A5 : 0.00000000434155749522
    • Ozone Depletion Kg Equivalent Cfc 11 Maintenance B2 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Repair B3 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Replacement B4 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Operational Energy Use B6 : 0.00000103177928547479
    • Ozone Depletion Kg Equivalent Cfc 11 End Of Life C1 C4 : 0.00000024081559619346
    • Ozone Depletion Kg Equivalent Cfc 11 Benefits Loads Beyond System Boundaries D : -0.00000288488890378351
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Total Life Cycle : 0.7277768701942758
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Manufacturing A1 A3 : 0.1598559301931018
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Distribution A4 : 0.03156022282076528
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Installation A5 : 0.000516625558826004
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Maintenance B2 : 0
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Repair B3 : 0
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Replacement B4 : 0
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Operational Energy Use B6 : 0.5148511176768514
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv End Of Life C1 C4 : 0.020992973944731347
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Benefits Loads Beyond System Boundaries D : -0.042356389563904404
    • Radioactive Waste Disposed Of Kg Total Life Cycle : 0.022564721657265217
    • Radioactive Waste Disposed Of Kg Manufacturing A1 A3 : 0.011352470569463972
    • Radioactive Waste Disposed Of Kg Distribution A4 : 0.0008763246288804455
    • Radioactive Waste Disposed Of Kg Installation A5 : 0.00000712336166985829
    • Radioactive Waste Disposed Of Kg Maintenance B2 : 0
    • Radioactive Waste Disposed Of Kg Repair B3 : 0
    • Radioactive Waste Disposed Of Kg Replacement B4 : 0
    • Radioactive Waste Disposed Of Kg Operational Energy Use B6 : 0.010053410616301998
    • Radioactive Waste Disposed Of Kg End Of Life C1 C4 : 0.00027539248094894284
    • Radioactive Waste Disposed Of Kg Benefits Loads Beyond System Boundaries D : -0.005912085030779842
    • Terrestrial Eutrophication Mole Of N Equiv Total Life Cycle : 2.501209080093116
    • Terrestrial Eutrophication Mole Of N Equiv Manufacturing A1 A3 : 0.46329964141935404
    • Terrestrial Eutrophication Mole Of N Equiv Distribution A4 : 0.09652566134012948
    • Terrestrial Eutrophication Mole Of N Equiv Installation A5 : 0.002433585184249467
    • Terrestrial Eutrophication Mole Of N Equiv Maintenance B2 : 0
    • Terrestrial Eutrophication Mole Of N Equiv Repair B3 : 0
    • Terrestrial Eutrophication Mole Of N Equiv Replacement B4 : 0
    • Terrestrial Eutrophication Mole Of N Equiv Operational Energy Use B6 : 1.8635992056221025
    • Terrestrial Eutrophication Mole Of N Equiv End Of Life C1 C4 : 0.07535098652728053
    • Terrestrial Eutrophication Mole Of N Equiv Benefits Loads Beyond System Boundaries D : -0.11646418950856943
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 8.089074847860557
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 8.089074847860557
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Maintenance B2 : 0
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Repair B3 : 0
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Replacement B4 : 0
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 0
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Benefits Loads Beyond System Boundaries D : 0
    • Total Use Of Primary Energy During The Life Cycle Mj Total Life Cycle : 8126.157149858225
    • Total Use Of Primary Energy During The Life Cycle Mj Manufacturing A1 A3 : 909.5465468800267
    • Total Use Of Primary Energy During The Life Cycle Mj Distribution A4 : 54.843069665702814
    • Total Use Of Primary Energy During The Life Cycle Mj Installation A5 : 2.4260458334688564
    • Total Use Of Primary Energy During The Life Cycle Mj Maintenance B2 : 0
    • Total Use Of Primary Energy During The Life Cycle Mj Repair B3 : 0
    • Total Use Of Primary Energy During The Life Cycle Mj Replacement B4 : 0
    • Total Use Of Primary Energy During The Life Cycle Mj Operational Energy Use B6 : 7054.924767368661
    • Total Use Of Primary Energy During The Life Cycle Mj End Of Life C1 C4 : 104.4167201103659
    • Total Use Of Primary Energy During The Life Cycle Mj Benefits Loads Beyond System Boundaries D : -385.3341469300907
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 1035.4549769291111
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 17.91853787185234
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0.00035855255495264584
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.19137092575429734
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Maintenance B2 : 0
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Repair B3 : 0
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Replacement B4 : 0
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 1012.1737322537232
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 5.170977325226363
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Benefits Loads Beyond System Boundaries D : -3.6207757078911365
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 8.089074847860557
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 8.089074847860557
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Maintenance B2 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Repair B3 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Replacement B4 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Benefits Loads Beyond System Boundaries D : 0
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 7082.613098081257
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 883.5389341603137
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 54.84271111314786
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 2.2346749077145596
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Maintenance B2 : 0
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Repair B3 : 0
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Replacement B4 : 0
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 6042.751035114941
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 99.24574278513953
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Benefits Loads Beyond System Boundaries D : -381.71337122219956
    • Use Of Non Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Non Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Non Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Non Renewable Secondary Fuels Mj Maintenance B2 : 0
    • Use Of Non Renewable Secondary Fuels Mj Repair B3 : 0
    • Use Of Non Renewable Secondary Fuels Mj Replacement B4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Non Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Benefits Loads Beyond System Boundaries D : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 7.247468906789411
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 7.247468906789411
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Maintenance B2 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Repair B3 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Replacement B4 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Benefits Loads Beyond System Boundaries D : 0
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 1028.2075080223217
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 10.671068965062938
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0.00035855255495264584
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.19137092575429734
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Maintenance B2 : 0
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Repair B3 : 0
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Replacement B4 : 0
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 1012.1737322537232
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 5.170977325226363
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Benefits Loads Beyond System Boundaries D : -3.6207757078911365
    • Use Of Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Renewable Secondary Fuels Mj Maintenance B2 : 0
    • Use Of Renewable Secondary Fuels Mj Repair B3 : 0
    • Use Of Renewable Secondary Fuels Mj Replacement B4 : 0
    • Use Of Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Renewable Secondary Fuels Mj Benefits Loads Beyond System Boundaries D : 0
    • Use Of Secondary Materials Kg Total Life Cycle : 0
    • Use Of Secondary Materials Kg Manufacturing A1 A3 : 0
    • Use Of Secondary Materials Kg Distribution A4 : 0
    • Use Of Secondary Materials Kg Installation A5 : 0
    • Use Of Secondary Materials Kg Maintenance B2 : 0
    • Use Of Secondary Materials Kg Repair B3 : 0
    • Use Of Secondary Materials Kg Replacement B4 : 0
    • Use Of Secondary Materials Kg Operational Energy Use B6 : 0
    • Use Of Secondary Materials Kg End Of Life C1 C4 : 0
    • Use Of Secondary Materials Kg Benefits Loads Beyond System Boundaries D : 0
    • Water Use M3 Eq Total Life Cycle : 27.49379882994426
    • Water Use M3 Eq Manufacturing A1 A3 : 10.46252309198043
    • Water Use M3 Eq Distribution A4 : 0.22361907183057161
    • Water Use M3 Eq Installation A5 : 0.011056813357214366
    • Water Use M3 Eq Maintenance B2 : 0
    • Water Use M3 Eq Repair B3 : 0
    • Water Use M3 Eq Replacement B4 : 0
    • Water Use M3 Eq Operational Energy Use B6 : 15.720382942274187
    • Water Use M3 Eq End Of Life C1 C4 : 1.0762169105018606
    • Water Use M3 Eq Benefits Loads Beyond System Boundaries D : -8.51017057268735
    • Air Pollution M3 Total Life Cycle : 0
    • Air Pollution M3 Manufacturing A1 A3 : 0
    • Air Pollution M3 Distribution A4 : 0
    • Air Pollution M3 Installation A5 : 0
    • Air Pollution M3 Maintenance B2 : 0
    • Air Pollution M3 Repair B3 : 0
    • Air Pollution M3 Replacement B4 : 0
    • Air Pollution M3 Operational Energy Use B6 : 0
    • Air Pollution M3 End Of Life C1 C4 : 0
    • Air Pollution M3 Benefits Loads Beyond System Boundaries D : 0
    • Water Pollution M3 Total Life Cycle : 0
    • Water Pollution M3 Manufacturing A1 A3 : 0
    • Water Pollution M3 Distribution A4 : 0
    • Water Pollution M3 Installation A5 : 0
    • Water Pollution M3 Maintenance B2 : 0
    • Water Pollution M3 Repair B3 : 0
    • Water Pollution M3 Replacement B4 : 0
    • Water Pollution M3 Operational Energy Use B6 : 0
    • Water Pollution M3 End Of Life C1 C4 : 0
    • Water Pollution M3 Benefits Loads Beyond System Boundaries D : 0
  • General Attributes
    • Product Or Component Type : Mechanically Held Lighting Contactor
    • Range Of Product : 8903LX
  • Environment Attributes
    • ROHS Exemption Information : Yes
    • China ROHS url : https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=exportPdfRoHSChina&pid=551815&lang=en-us
    • Take Back : No
    • Reach Free SHVC : Yes
    • Halogene Performance : Halogen free plastic parts product
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 329.2784736461138
    • Environmental Disclosure : ENVPEP1407018EN
    • EU ROHS Directive : Compliant
    • Halogen Content Performance : Halogen free plastic parts product
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Free Of SVHC : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1407018EN
    • Pep Verification Date : 2025-10-15
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Country of Origin : Mexico
    • Compliance : TAA