8 temperature sensor module MET148-2 for Sepam series 20, 40, 60, 80

8 temperature sensor module ME

SQD59641 59641 3303430596417
1076.88 / EA
http://schema.org/OutOfStock
  • Depth: 30 mm
  • Module Type: Temperature Sensor
External 8 temperature sensors module MET148-2 for Schneider Electric's protection relays. This module can be used to ensure direct temperature measurements with Resistance Temperature Detectors (RTDs). It can be connected to the protection relay any time: during installation, commissioning or even during maintenance. This module provides 8 Resistance Temperature Detector (RTD) inputs. This external module can work with Pt100, Ni100 and Ni120 types of Resistance Temperature Detectors. Connection is made thru screw-type terminals. This module does not require auxiliary power supply. It is powered by Easergy P5. The product dimensions are 88 mm in height (3.46 in), 144 mm in width (5.70 in) and 30 mm in depth 1.18 in) for a net weight of 200 g (0.440 lbs). Easergy P5 is compliant with EN 60255-26, EN 60255-27 standards and with UL Standard. It provides Marine certification. This product can be installed on symmetrical DIN rail. Connection cords (59660, 59661, 59662).
QTY
  • Product Description
  • Specifications
External 8 temperature sensors module MET148-2 for Schneider Electric's protection relays. This module can be used to ensure direct temperature measurements with Resistance Temperature Detectors (RTDs). It can be connected to the protection relay any time: during installation, commissioning or even during maintenance. This module provides 8 Resistance Temperature Detector (RTD) inputs. This external module can work with Pt100, Ni100 and Ni120 types of Resistance Temperature Detectors. Connection is made thru screw-type terminals. This module does not require auxiliary power supply. It is powered by Easergy P5. The product dimensions are 88 mm in height (3.46 in), 144 mm in width (5.70 in) and 30 mm in depth 1.18 in) for a net weight of 200 g (0.440 lbs). Easergy P5 is compliant with EN 60255-26, EN 60255-27 standards and with UL Standard. It provides Marine certification. This product can be installed on symmetrical DIN rail. Connection cords (59660, 59661, 59662).
  • Complementary Attributes
    • Maximum Distance Between Sensor And Module : 1 km
  • Important Information Attributes
    • Auxiliary Connection Terminal : earthing terminal screw-type connectors cable <1000 m, earthing terminal screw-type connectors tinned copper braid 6-100 mm² <1000 m, RTDs screw-type connectors 1 wire 0.2-2.5 mm², RTDs screw-type connectors 2 wire 0.2-1 mm²
    • Electromagnetic Compatibility : disturbing field emission emission tests) A EN 550221 MHz damped oscillating wave 2.5 kV CM, 1 kV DM immunity tests-conducted disturbances) IEC 60255-22-1, fast transient bursts 4 kV, 2.5 kHz immunity tests-conducted disturbances) ANSI C37.90.1, fast transient bursts 4 kV, 2.5 kHz/2 kV, 5 kHz immunity tests-conducted disturbances) A and B IEC 60255-22-4, fast transient bursts 4 kV, 2.5 kHz immunity tests-conducted disturbances) IV IEC 61000-4-4, immunity to conducted RF disturbances 10 V immunity tests-conducted disturbances) III IEC 60255-22-6, immunity to magnetic fields at network frequency 30 A/m (continuous)-300 A/m (1-3 s) immunity tests-radiated disturbances) IV IEC 61000-4-8, immunity to radiated fields 10 V/m, 80 MHz...1 GHz immunity tests-radiated disturbances) IEC 60255-22-3, immunity to radiated fields 35 V/m, 25 MHz...1 GHz immunity tests-radiated disturbances) ANSI C37.90.2, immunity to radiated fields 10 V/m, 80 MHz...2 GHz immunity tests-radiated disturbances) III IEC 61000-4-3, surges 2 kV CM, 1 kV DM immunity tests-conducted disturbances) III IEC 61000-4-5, voltage interruptions 100 % during 100 ms immunity tests-conducted disturbances) IEC 60255-11, 1 MHz damped oscillating wave 2.5 kV CM, 2.5 kV DM immunity tests-conducted disturbances) ANSI C37.90.1, 100 kHz damped oscillating wave 2.5 kV CM, 1 kV DM immunity tests-conducted disturbances) IEC 61000-4-12, conducted disturbance emission emission tests) IEC 60255-25, conducted disturbance emission emission tests) A EN 55022, disturbing field emission emission tests) IEC 60255-25, electrostatic discharge 8 kV air, 4 kV contact immunity tests-radiated disturbances) ANSI C37.90.3, electrostatic discharge 8 kV air, 6 kV contact immunity tests-radiated disturbances) IEC 60255-22-2
    • Mechanical Robustness : earthquakes in operation 2) 1 Gn (vertical axes) IEC 60255-21-3, earthquakes in operation 2) 2 Gn (horizontal axes) IEC 60255-21-3, jolts de-energized 2) 20 Gn/16 ms IEC 60255-21-2, shocks de-energized 2) 27 Gn/11 ms IEC 60255-21-2, shocks in operation 2) 10 Gn/11 ms IEC 60255-21-2, vibrations de-energized 2) 2 Gn, 10 Hz...150 Hz IEC 60255-21-1, vibrations in operation 2) 1 Gn, 10 Hz...150 Hz IEC 60255-21-1, vibrations in operation Fc) 2 Hz...13.2 Hz, a = +/- 1 mm IEC 60068-2-6
    • Range Of Product : Sepam series 80, Sepam series 60, Sepam series 80 NPP, Sepam series 40, Sepam series 20
    • Temperature Probe Type : Ni 100/Ni 120, <4 mA isolation from earth: none, Pt 100, <4 mA isolation from earth: none
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-04-24
    • Return Indicator : N
    • Stocking Flag : Y
    • Device Type : Relay, Control & Measurement - Protection relay
    • Serviceability : No
    • Traceability : No
    • Weee Scope : Out
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1411007_V1
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : No
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 2022
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • China Rohs Label : 7
    • With Recycled Cardboard : No
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Product Kit Identifier : N
    • Device Short Name : MET148-2
    • Energy Efficiency Optimized : False
    • Module Type : temperature sensor
    • Mounting Mode : fixed
    • Mounting Support : symmetrical DIN rail
    • Product Availability : Stock - Normally stocked in distribution facility
    • Returnability : No
    • Sustainable Packaging : No
    • Tightening Torque : earthing terminal: 2.2-2.2 N.m
    • Type Of Measurement : Temperature
    • Pep Code : ENVPEP1411007_V1
    • Height Nominal : 88 mm
    • Width Nominal : 144 mm
    • Nbr. Of Units In Pkg. : 1
    • Package Weight(Lbs) : 232.600 g
    • Take-back : No
    • Warranty (In Months) : 18
    • Customs Code : 9025198085
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : -25-70 °C, -25-70 °C
    • Climatic Withstand : influence of corrosion/gaz test 2 in operation) 21 days, 75 % RH, 25 °C, 0.5 ppm H2S, 1 ppm S02 IEC 60068-2-60, salt mist in operation) Kb/2 6 days IEC 60068-2-52, temperature variation with specified variation rate in storage) Nb - 25 °C to 70 °C, 5 °C/min IEC 60068-2-14, influence of corrosion/gaz test 4 in operation) 21 days, 75 % RH, 25 °C, 0.01 ppm H2S, 0.2 ppm S02, 0.2 ppm NO2, 0.01 ppm CI2 IEC 60068-2-60, continuous exposure to damp heat in operation) Cab 10 days, 93 % RH, 40 °C IEC 60068-2-78, continuous exposure to damp heat in storage) Cab 56 days, 93 % RH, 40 °C IEC 60068-2-78, continuous exposure to damp heat in storage) Db 6 days, 95 % RH, 55 °C IEC 60068-2-30, exposure to cold in operation) Ad - 25 °C IEC 60068-2-1, exposure to cold in storage) Ab - 25 °C IEC 60068-2-1, exposure to dry heat in operation) Bd 70 °C IEC 60068-2-2, exposure to dry heat in storage) Bb 70 °C IEC 60068-2-2
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Mercury Free : Yes
    • Circularity Profile : ENVEOLI1411007_V1
    • Environmental Disclosure : ENVPEP1411007_V1
    • Eu Rohs Directive : Compliant By Exemption
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1411007_V1
  • General Attributes
    • Range Of Product : Sepam series 80, Sepam series 60, Sepam series 80 NPP, Sepam series 40, Sepam series 20
  • Input Attributes
    • Number Of Inputs : 8
  • Specifications
    • Country of Origin : Brazil, France, Mexico, Romania, United States
    • Depth : 30 mm