universal protection relay, PowerLogic P3U 3CT 1Io 16DI 8DO 24-48V DI24 RS485 RL

UNIVERSAL PROTECTION RELAY, PO

SQDREL53092 REL53092 3606487107118
3595.94 / EA
http://schema.org/OutOfStock
  • Country of Origin: USA
  • Depth: 205 mm
  • Display Type: LCD 128 X 64 Pixels With Single Line Diagram
  • Height: 169.5 mm
  • Net Weight: 2.5 kg
  • Number of Outputs: 1 Watchdog, 8 DO
  • Warranty Length: 10 yr, 2 yr
  • Width: 170 mm
QTY
  • Specifications
  • Environment
    • Mechanical Robustness : vibrations class II) IEC 60255-21-1 || vibrationsFc IEC 60068-2-6 || shocks class II) IEC 60255-21-2 || shocksEa IEC 60068-2-27 || seismic tests method A class II) IEC 60255-21-3
    • Ambient Air Temperature For Operation : -40-65 °C
    • Environmental Characteristic : exposure to dry heat Bb EN/IEC 60068-2-2 || exposure to cold Ad EN/IEC 60068-2-1 || exposure to damp heat in service Db EN/IEC 60068-2-30 || exposure to damp heat in service Cab EN/IEC 60068-2-78
    • Ip Degree Of Protection : IP54 front IEC 60529
    • Electromagnetic Compatibility : emission tests IEC/EN 60255-26 ed. 3 || emission tests class A CISPR 11 || emission tests class A CISPR 22 || EMC immunity IEC/EN 60255-26 ed. 3 || EMC immunity EN/IEC 61000-4-18 || EMC immunity level 4 EN/IEC 61000-4-2 || EMC immunity level 3 EN/IEC 61000-4-3 || EMC immunity level 4 EN/IEC 61000-4-4 || EMC immunity level 3 EN/IEC 61000-4-5 || EMC immunity level 3 EN/IEC 61000-4-6 || EMC immunity EN/IEC 61000-4-8 || EMC immunity level 5 EN/IEC 61000-4-9 || EMC immunity EN/IEC 61000-4-29 || EMC immunity EN/IEC 61000-4-11 || EMC immunity EN/IEC 61000-4-17
    • Relative Humidity : 0-95 %, without condensation
    • Protective Treatment : conformal coating
    • Operating Altitude : 6561.68 ft (2000 m)
  • Contractual warranty
    • Warranty : up to 10 years (Standard warranty 2 years. Please check with your local SE representative for extended warranty availability and conditions)
  • Environmental data
    • Packaging Made With Recycled Cardboard : Yes
    • Environmental Disclosure : ENVPEP1706006_V1
    • Packaging Without Single Use Plastic : No
    • Scip Number : 7fd15df9-a702-4a28-ad01-afb36a7b785f
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Minimum Percentage Of Recycled Plastic Content : 0
    • Circularity Profile : ENVEOLI1706006_V1
    • Take-Back : No
  • Complementary
    • Number Of Key : 2 customizable
    • Local Signalling : 4 LEDs || 8 LEDs programmable
    • Depth : 205 mm
    • Operating Threshold : 24 V AC/DC
    • Width : 170 mm
    • Height : 169.5 mm
    • Display Type : LCD 128 x 64 pixels with single line diagram
    • Net Weight : 2.5 kg maximum
    • Software Name : eSetup Easergy Pro virtual simulation test || Easergy SmartApp
    • Web Server : embedded HTTP server
  • Specifications
    • Country of Origin : United States
    • Analogue Output Number : 0
    • Input Type : 3 1/5 A CT phase current || 1 1/5 A CT residual current || 4 100 V/110 V VT voltage
    • Range Of Product : PowerLogic P3
    • Connections - Terminals : screw removable (digital input/output) || pin removable (voltage transformer) || pin removable (current transformer)
    • Network And Machine Diagnosis Type : event recording || disturbance recording || tripping context
    • Device Mounting : flush
    • Number Of Outputs : 8 DO || 1 watchdog
    • Protection Type : broken conductor 46 I2/I1 || cold load pick-up 50BF || switch ON to fault (SOTF) 27P || programmable curve 99 8-8 || capacitor bank unbalance 51C || phase overcurrent 50/51 || directional earth fault 67N || H5 detection 68H5 || directional phase overcurrent 67 || earth fault overcurrent 50N/51N || transient earth fault 67NI || cold load pick-up || H2 detection 68H2 || breaker failure 50BF || switch ON to fault (SOTF) || directional active underpower 37P || fault locator 21FL || recloser 79 || phase undercurrent 37 || excessive starting time, locked rotor 48/51LR || motor restart inhibition 66 || capacitor overvoltage 59C || negative sequence overcurrent 46 || overvoltage 59 || undervoltage 27 || positive sequence undervoltage 27P || earth fault overvoltage 59N || underfrequency 81/81N || rate of change of frequency 81R || synchro-check 25 || lockout relay 86 || CT supervision 60 || VT supervision 60 || programmable stages 99 8-8
    • Relay Application : universal
    • Communication Port Protocol : IEC 60870-5-101 || IEC 60870-5-103 || DNP3 || Modbus RTU || DeviceNet || SPAbus
    • Product Or Component Type : protection relay
    • Single Line Diagram : 4 controlled + 8 displayed
    • Mounting Case Size : 30TE
    • Monitoring Function : trip circuit supervision 74 || circuit breaker monitoring || relay self-monitoring
    • Analogue Input Number : 0
    • Mounting Mode : flush mounting
    • Control Type : switchgear control and monitoring || programmable switchgear interlocking || local control on single-line diagram || local control with I/O keys || local/remote control || 2 function keys || mobile application with Easergy SmartApp || web-server || programmable logic
    • Digital Input Number : 16
    • Setting : 4
    • Integrated Connection Type : front USB port 1 || rear RS485 1
    • Cybersecurity : password protection || port hardening
    • Switchgear Diagnosis Type : CT supervision TCS || trip circuit supervision TCS
    • Arc Flash Protection : no
    • Type Of Measurement : current 3-phase || current zero sequence || current negative sequence || RMS reactive power zero sequence || apparent power negative sequence || RMS apparent power phase to earth || active energy phase to phase || reactive energy zero sequence || cos φ positive sequence || tan φ ratio of negative and positive || condition monitoring CB wear 2nd, 15th harmonics with THD || short circuit fault reactance || active power || fault location current || current positive sequence || frequency || RMS active power || reactive power || current ratio of negative and positive || voltage phase to earth || voltage phase to phase || voltage zero sequence || voltage positive sequence || voltage negative sequence || voltage ratio of negative and positive || earth fault reactance || RMS reactive power || apparent power || RMS apparent power || active energy || reactive energy || cos φ || tan φ || power angle || power factor || voltage phasor diagram view || current phasor diagram view || current 2nd, 15th harmonics with THD || voltage 2nd, 15th harmonics with THD || condition monitoring CB wear || voltage interruption
    • Device Short Name : P3U30-6ABA1BBAB
    • [Us] Rated Supply Voltage : 24...48 V DC