Schneider Electric at Mayer

voltage control relay, Harmony Control Relays, 8A, 2CO, overvoltage or undervoltage detection, 1...100V AC DC, 24...240V AC DC

V MON RLY, 24-240VAC IN, 1-10

SQDRM22UA32MR RM22UA32MR 3606480792243
130.31 / EA
http://schema.org/OutOfStock
This Harmony RM22-UA relay allows monitoring of voltage control in single phase networks. This modular multi function single phase voltage control relay is ideal for monitoring of electrical values in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market slim form-factors with 22.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device. It also offers a diagnostic button, sealable cover, simple and precise settings with screw trimmers. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0
QTY
  • Product Description
  • Features
  • Specifications
This Harmony RM22-UA relay allows monitoring of voltage control in single phase networks. This modular multi function single phase voltage control relay is ideal for monitoring of electrical values in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market slim form-factors with 22.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device. It also offers a diagnostic button, sealable cover, simple and precise settings with screw trimmers. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • Maximum Switching Current : 8 A AC
    • Maximum Switching Voltage : 250 V AC
    • Minimum Switching Current : 10 mA 5 V DC
    • Us Rated Supply Voltage : 24...240 V AC/DC 50/60 Hz, non self-powered
    • Line Rated Current : 8 A
    • Maximum Measuring Cycle : 100 ms measurement cycle as true rms value
    • Maximum Power Consumption In W : 1.5 W DC
    • Uc Control Circuit Voltage : 24...240 V
  • Important Information Attributes
    • Persona Type Ids : BM9, EU, LC, OM, OM8, PB, SC, SI, VR
    • Persona Type Names : Charge Point Operator, End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, Electrician, System Integrator, IT Channel Partner
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Dielectric Test Voltage : 2.5 kV AC 50 Hz, 1 min IEC 60255-27
    • Electromagnetic Compatibility : immunity for residential, commercial and light-industrial environments conforming to IEC 61000-6-1, immunity for industrial environments conforming to IEC 61000-6-2, emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3, emission standard for industrial environments conforming to IEC 61000-6-4, electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2, electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2, radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 conforming to IEC 61000-4-3, electrical fast transient/burst immunity test - test level: 4 kV level 4 (direct) conforming to IEC 61000-4-4, electrical fast transient/burst immunity test - test level: 2 kV level 4 (capacitive coupling) conforming to IEC 61000-4-4, surge immunity test - test level: 4 kV level 4 (common mode) conforming to IEC 61000-4-5, surge immunity test - test level: 2 kV level 4 (differential mode) conforming to IEC 61000-4-5, conducted and radiated emissions class B group 1 conforming to CISPR 11, conducted and radiated emissions class B conforming to CISPR 22
    • Hysteresis : 3-3 % fixed full scale for window mode, 5-50 % adjustable threshold setting
    • Immunity To Microbreaks : 10 ms
    • Insulation Resistance : > 100 MOhm 500 V DC, > 100 MOhm 500 V DC, > 100 MOhm 500 V DC> 100 MOhm 500 V DC, > 100 MOhm 500 V DC, > 100 MOhm 500 V DC
    • Measurement Error : < 1 % over the whole range with voltage variation, < 1 % over the whole range with voltage variation< 1 % over the whole range with voltage variation, < 1 % over the whole range with voltage variation, 0.05 %/°C with temperature variation
    • Measurement Range : 1...100 V AC/DC
    • Mounting Support : 35 mm DIN rail conforming to IEC 60715
    • Overvoltage Category : III conforming to IEC 60664-1
    • Power Consumption In Va : 3.5-3.5 VA AC
    • Relay Monitored Parameters : undervoltage and overvoltage in window mode, overvoltage or undervoltage detection
    • Repeat Accuracy : +/- 0.5 % input and measurement circuit, +/- 0.5 % input and measurement circuit, +/- 2 % time delay, +/- 2 % time delay+/- 0.5 % input and measurement circuit, +/- 0.5 % input and measurement circuit, +/- 2 % time delay, +/- 2 % time delay
    • Reset Time : 1500 ms at maximum voltage
    • Resistance Across Terminals : 110 kOhm E2-M terminals, 22 kOhm E1-M terminals, 220 kOhm E3-M terminals
    • Run Up Delay At Power Up : 600 ms
    • Safety Reliability Data : B10d = 290000, MTTFd = 308.2 years
    • Shock Resistance : 15 gn 11 ms) not in operation IEC 60068-2-27, 5 gn 11 ms) in operation IEC 60068-2-27
    • Supply Voltage Limits : 20.4-264 V AC/DC
    • Tightening Torque : 0.6-1 N.m IEC 60947-1
    • Time Delay Type : adjustable 0.1...30 s, +/- 10 % of the full scale value Tt- time delay upon fault
    • Utilisation Category : AC-15 IEC 60947-5-1, DC-13 IEC 60947-5-1, AC-1 IEC 60947-4-1, DC-1 IEC 60947-4-1
    • Vibration Resistance : 0.075 mm 10-58.1 Hz) not in operation IEC 60068-2-6, 1 gn 10-58.1 Hz) not in operation IEC 60068-2-6, 0.035 mm 58.1-150 Hz) in operation IEC 60068-2-6, 0.5 gn 58.1-150 Hz) in operation IEC 60068-2-6
    • Connections Terminals : screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end, screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end, screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end, screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end, screw connectors
    • Carbon Footprint Of The Distribution Phase A4 : 0.094633666678876, 0.1 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.32555876144474577, 0.3 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0 kg CO2 eq., 0.0008761080357477365
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 3 kg CO2 eq., 2.8007273826408867
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 41 kg CO2 eq., 40.75904111642341
    • Certificate Agency : GL, UL, CCC, EAC, CE, RCM, CSA
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-03-26
    • Return Indicator : N
    • Stocking Flag : Y
    • Stock Policy : 2
    • Weee Scope : Out
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2506066EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : No
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 1930
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • China Rohs Label : 5
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Compatibility Code : RM22
    • Contacts Material : cadmium free
    • Contacts Type And Composition : 2 C/O
    • Control Type : with test button
    • Electrical Durability : 100000 cycles
    • Functionality : undervoltage and overvoltage in window mode
    • Housing Material : polycarbonate
    • Insulation : between supply and measurement
    • Mechanical Durability : 10000000 cycles
    • Phase : 1 phase
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : voltage control relay
    • Range Of Product : Harmony Control Relays
    • Relay Name : RM22UA
    • Relay Type : voltage control relay
    • Response Time : <= 500 ms<= 500 ms
    • Returnability : No
    • Software Version : v6.2.5-6
    • Supply Circuit Type : DC
    • Sustainable Packaging : Yes
    • Switching Capacity In Va : 2000 VA
    • Total Lifecycle Carbon Footprint : 44 kg CO2 eq.
    • Warranty In Months : 18
    • Pep Code : ENVPEP2506066EN
    • Database Version : 2024-01
    • Pep Verification Date : 2025-06-30
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional-unit Description : To switch ON/OFF electrical contacts when the abnormal operating conditions is detected during 10 years and a 80% use rate.
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unit
    • Reference Lifetime, In Y : 10
    • Energy Model - Manufacturing [A1-a3] : Electricity Mix; High voltage; 2020; Indonesia, ID
    • Energy Model - Installation [A5] : No energy used
    • Energy Model - Use [B6] : Electricity Mix; Low voltage; 2020; Global, GLO
    • Energy Model - End Of Life [C1-c4] : Global, European and French datasets are used.
    • Recyclability Potential, In % : 18
    • Offer Owner Code : 190786
    • Pn : 1
    • Width Nominal : 22.5 mm
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : -20-50 °C 60 Hz, -20-50 °C 60 Hz, -20-60 °C 50 Hz, -20-60 °C 50 Hz-20-50 °C 60 Hz, -20-50 °C 60 Hz, -20-60 °C 50 Hz
    • Ambient Air Temperature For Storage : -40-70 °C, -40-70 °C
    • Ip Degree Of Protection : IP20 IEC 60529 terminals), IP40 IEC 60529 housing), IP50 IEC 60529 front panel)
    • Relative Humidity : 93-97 % 25-55 °C IEC 60068-2-30
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 43.980837035223665
    • Circularity Profile : ENVEOLI2506066EN
    • Environmental Disclosure : ENVPEP2506066EN
    • Eu Rohs Directive : Compliant By Exemption
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2506066EN
    • Pep Verification Date : 2025-06-30
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Phase : 1 phase
    • Product Or Component Type : voltage control relay
    • Range Of Product : Harmony Control Relays
  • ETIM
    • ETIM 8 : EC001438
    • ETIM 9 : EC001438
  • Output Attributes
    • Nominal Output Current : 8 A
    • Output Contacts : 2 C/O
  • Specifications
    • Country of Origin : Brazil, France, Indonesia