Variable speed drive, Altivar Solar, 4.0kW, 380 to 500V, 3 phases, compact

VARIABLE SPEED DRIVE, ALTIVAR

SQDATV320U40N4C412 3606486835920
1350.95 / EA
http://schema.org/OutOfStock
  • Depth: 158.0 mm
  • Operating Position: Vertical +/- 10 Degree
Altivar Solar variable speed drive range is designed to improve pump performance and increase pump availability while reducing the total system cost. They are robust, simple to commission, and easily integrated into different machine layouts and cabinets. It controls motors of 4kW/5HP power rating with a three-phase supply voltage of 380…500V 50/60Hz. It embeds dedicated functions for synchronous motors, ATV logic, and pumping and safety functions. Altivar Solar VSD integrates the Modbus and CANopen communication protocols as standard. The Altivar Solar VFDs have a compact control block design. Its dimensions are 140mm (width) x 184mm (depth) x 158mm (height) and it weighs 2.2kg. Altivar Solar drives bring key benefits to our solar pump system builders. It conforms to IEC/EN/UL 61800-5-1, EN/IEC 61800-3 (Environments 1 and 2, category C2, C3), IEC 60721-3, IEC 61508, and IEC 13849-1. It is certified CE, UKCA, UR (UL recognized component), UL 61800-5-1, RCM, and RoHS EU and China. These drives have a dedicated compatibility mode function, enabling customers to replace a legacy product ATV312 Solar without changing the PLC program. Our Altivar Solar Sizer tool will help you design your Solar system. The Altivar Solar range achieves superior upgradable performance by enhancing its embedded functionality and performance capacity for hardware and software. It is a Green Premium product designed to take environmental considerations beyond current directives and regulations and complies with RoHS and REACH.
QTY
  • Product Description
  • Features
  • Specifications
Altivar Solar variable speed drive range is designed to improve pump performance and increase pump availability while reducing the total system cost. They are robust, simple to commission, and easily integrated into different machine layouts and cabinets. It controls motors of 4kW/5HP power rating with a three-phase supply voltage of 380…500V 50/60Hz. It embeds dedicated functions for synchronous motors, ATV logic, and pumping and safety functions. Altivar Solar VSD integrates the Modbus and CANopen communication protocols as standard. The Altivar Solar VFDs have a compact control block design. Its dimensions are 140mm (width) x 184mm (depth) x 158mm (height) and it weighs 2.2kg. Altivar Solar drives bring key benefits to our solar pump system builders. It conforms to IEC/EN/UL 61800-5-1, EN/IEC 61800-3 (Environments 1 and 2, category C2, C3), IEC 60721-3, IEC 61508, and IEC 13849-1. It is certified CE, UKCA, UR (UL recognized component), UL 61800-5-1, RCM, and RoHS EU and China. These drives have a dedicated compatibility mode function, enabling customers to replace a legacy product ATV312 Solar without changing the PLC program. Our Altivar Solar Sizer tool will help you design your Solar system. The Altivar Solar range achieves superior upgradable performance by enhancing its embedded functionality and performance capacity for hardware and software. It is a Green Premium product designed to take environmental considerations beyond current directives and regulations and complies with RoHS and REACH.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Communications & Management Attributes
    • Communication Port Protocol : Modbus serial, CANopen
  • Complementary Attributes
    • Maximum Switching Current : relay output R1A, R1B, R1C, R2A, R2C inductive, cos phi = 0.4 7 ms 2 A 30 V DCrelay output R2A, R2C resistive, cos phi = 1 5 A 30 V DCrelay output R1A, R1B, R1C resistive, cos phi = 1 3 A 250 V ACrelay output R1A, R1B, R1C resistive, cos phi = 1 3 A 30 V DC, relay output R1A, R1B, R1C, R2A, R2C inductive, cos phi = 0.4 7 ms 2 A 250 V ACrelay output R2A, R2C resistive, cos phi = 1 5 A 250 V AC
    • Brake Chopper Integrated : true
    • Maximum Associated Fuse Rating : 25.0 A
    • Maximum Input Current Per Phase : 13.7 A
    • Maximum Output Frequency : 0.599 kHz
    • Maximum Output Voltage : 500 V
    • Maximum Transient Current : 14.3 A 60 s
    • Minimum Switching Current : relay output R1A, R1B, R1C, R2A, R2C 5 mA 24 V DC
  • Important Information Attributes
    • Asynchronous Motor Control Profile : voltage/frequency ratio, 5 points, flux vector control without sensor, standard, voltage/frequency ratio - Energy Saving, quadratic U/f, flux vector control without sensor - Energy Saving, voltage/frequency ratio, 2 points
    • Electrical Connection : screw terminalscrew terminal 0.5...1.5 mm² analog input, screw terminal analog output
    • Electromagnetic Compatibility : electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3, electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-41.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6voltage dips and interruptions immunity test conforming to IEC 61000-4-11
    • Linearity Error : AI1, AI2, AI3 +/- 0.2...0.5 % of maximum value analog input, AQ1 +/- 0.3 % analog output
    • Local Signalling : 1 LED (red) for drive fault, 1 LED (red) for CANopen error1 LED (green) for CANopen run
    • Marking : CE, UR, UKCA, RCM
    • Motor Slip Compensation : automatic whatever the load, adjustable 0...300 %, not available in voltage/frequency ratio (2 or 5 points)
    • Number Of Addresses : 1-247, 1-127
    • Protection Type : input phase breaks drive, overcurrent between output phases and earth drive, overheating protection drive, short-circuit between motor phases drive, thermal protection drive
    • Refresh Time : logic input DI1...DI4)8 ms, relay output R1A, R1B, R1C)2 ms, relay output R2A, R2C)2 ms
    • Speed Accuracy : +/- 10 % of nominal slip 0.2 Tn to Tn, +/- 10 % of nominal slip 0.2 Tn to Tn, +/- 10 % of nominal slip 0.2 Tn to Tn, +/- 10 % of nominal slip 0.2 Tn to Tn
    • Certificate Agency : CE, UR, UKCA, RCM
    • Environmental Class (During Operation) : class 3C3 according to IEC 60721-3-3, class 3S2 according to IEC 60721-3-3
    • Environmental Class (During Storage) : class 1C3 according to EN 60721-3, class 1S2 according to EN 60721-3
    • Environmental Class (During Transport) : class 2C3 according to EN 60721-3, class 2S1 according to EN 60721-3
    • Carbon Footprint Of The Distribution Phase [A4] : 0.5113537825251914, 0.5 kg CO2 eq.
    • Carbon Footprint Of The End-of-life Phase [C1 To C4] : 4.677962242358708, 5 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase [A5] : 0.5 kg CO2 eq., 0.4535141311111357
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 51 kg CO2 eq., 50.89051692169745
    • Carbon Footprint Of The Use Phase [B2 B3 B4 B6] : 2 420 kg CO2 eq., 2419.952194694455
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-01-12
    • Return Indicator : Y
    • Stocking Flag : N
    • Stock Policy : 2
    • Device Type : Variable speed drive - VSD Compacts
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : IDIBS
    • Average Life Duration : 10 year(s)
    • Average Percentage Of Asi Certified Metals : 99 %
    • Weee Applicability : Finished product
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1512005EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : No
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 1650
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • China Rohs Label : 5
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Product Kit Identifier : N
    • 1 Phase Low Current Possible : false
    • 4 Quadrant Operation Possible : true
    • Apparent Power : 9.2 kVA 500 V heavy duty)
    • Application In Domestic And Commercial Area Permitted : false
    • Assembly Style : with heat sink
    • Base Load Current At High Overload : 9.5 A
    • Braking To Standstill : by DC injection
    • Braking Torque : 170 % with braking resistor
    • Capacity Of Dc Link : 550 µF
    • Computer Port : true
    • Data Format : 8 bits, configurable odd, even or no parity
    • Design Of Frequency Changer : U converter
    • Emc Filter : Class C2 EMC filter integrated
    • Encoder Protocol : RS 422
    • Format Of The Drive : compact
    • Housing Material : plastic
    • Line Current : 13.7 A 380 V heavy duty)10.6 A 500 V heavy duty)
    • Maximum Associated Fuse Rating : 25.0 A
    • Maximum Input Current Per Phase : 13.7 A
    • Method Of Access : slave CANopen
    • Motor Power Kw : 4.0 kW heavy duty
    • Mounting Mode : wall mount
    • Network Frequency : 50-60 Hz
    • Network Number Of Phases : 3 phase
    • Noise Level : 52 dB
    • Nominal Switching Frequency : 4 kHz
    • Number Of Hw Interfaces Industrial Ethernet : 0.0
    • Number Of Hw Interfaces Other : 1.0
    • Number Of Hw Interfaces Parallel : 0.0
    • Number Of Hw Interfaces Profinet : 0.0
    • Number Of Hw Interfaces Serial Rs23 : 0.0
    • Number Of Hw Interfaces Serial Rs42 : 0.0
    • Number Of Hw Interfaces Serial Rs485 : 1.0
    • Number Of Hw Interfaces Serial Tty : 0.0
    • Number Of Hw Interfaces Usb : 0.0
    • Number Of Output Phases : 3
    • Operating Element Present : true
    • Operating Position : vertical +/- 10 degree
    • Optical Interface Present : false
    • Option Card : communication module, Ethernet IP/Modbus TCP
    • Overvoltage Category : II
    • Phase : 3 phase
    • Power Dissipation In W : fan 111 W 380 V 4 kHz
    • Power Factor : 0.563 at 380 V
    • Power Loss Per Device Current Dependent : 111 W
    • Power Loss Static Current Independent : 111 W
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : variable speed drive
    • Product Specific Application : pumping applications
    • Prospective Line Isc : 5 kA
    • Range Of Product : Altivar Solar
    • Regulation Loop : adjustable PID regulator
    • Relative Symmetric Mains Voltage Tolerance : 10 %
    • Relative Symmetric Network Frequency Tolerance : 5 %
    • Returnability : Yes
    • Sampling Duration : 2 ms - 15...10 % AI1, AI2, AI3) - analog input2 ms AQ1) - analog output
    • Software Version : v6.1
    • Supporting Protocol For Asi : false
    • Supporting Protocol For Bacnet : false
    • Supporting Protocol For Can : true
    • Supporting Protocol For Devicenet : true
    • Supporting Protocol For Devicenet Safety : false
    • Supporting Protocol For Foundation Fieldbus : false
    • Supporting Protocol For Interbus : false
    • Supporting Protocol For Knx : false
    • Supporting Protocol For Lon : false
    • Supporting Protocol For Modbus : true
    • Supporting Protocol For Other Bus Systems : true
    • Supporting Protocol For Profibus : true
    • Supporting Protocol For Profinet Cba : false
    • Supporting Protocol For Profinet Io : true
    • Supporting Protocol For Profisafe : false
    • Supporting Protocol For Safetybus P : false
    • Supporting Protocol For Sercos : false
    • Supporting Protocol For Suconet : false
    • Sustainable Packaging : Yes
    • Switching Frequency : 2...16 kHz adjustable4...16 kHz with derating factor
    • Synchronous Motor Control Profile : vector control without sensor
    • Total Lifecycle Carbon Footprint : 2 476 kg CO2 eq.
    • Transient Overtorque : 170-200 % of nominal motor torque
    • Type Of Polarization : no impedance
    • Updatability : Upgradeable through digital modules
    • Volume Of Cooling Air : 37.7 m3/h
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • With Safety Function Safe Programmable Logic : false
    • Application In Industrial Area Permitted : true
    • Supply Voltage Num : 380...500 V
    • Motor Power Kw 10 N Motor Power Kw : 4.0 kW
    • Pep Code : ENVPEP1512005EN
    • Database Version : 2023-02
    • Pep Verification Date : 2024-07-01
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3-EN-2023 06 06
    • Type Of Verification For The Pep : Independent external review
    • Data Source : extrapolated product
    • Functional-unit Description : To adapt the speed and torque of synchronous, asynchronous or reluctance motor to the machine's operating point for 4 kW for heavy duty electric motors for fluid management and industrial applications in IP20/UL type 1 conditions, at 380V to 500V rated 3-phases voltage supply. Calculation of the environmental impacts is based on 10 years of product service lifetime. The usage profile taken into account is 80% uptime in use phase at 75% loading rate and 20% uptime in stand by phase.
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unit
    • Reference Lifetime In Y : 10
    • Energy Consumption On Product Lifetime In Kwh : 5904.24
    • Energy Model - Manufacturing [A1-a3] : Indonesia, ID
    • Energy Model - Installation [A5] : Electricity Mix; Low voltage; 2018; Europe, EU-27
    • Energy Model - Use [B6] : Electricity Mix; Low voltage; 2018; Europe, EU-27
    • Energy Model - End Of Life [C1-c4] : Electricity Mix; Low voltage; 2018; Europe, EU-27
    • Recyclability Potential In % : 58
    • Height Nominal : 184.0 mm
    • Width Nominal : 140 mm
    • [Us] Rated Supply Voltage : 380...500 V380...500 V - 15...10 %
    • Short-circuit Protection : thermal protection
    • Emc Limit Value (Complied) : true
    • Maximum Acceleration Under Shock Impact (During Operation) : 150 m/s² at 11 ms
    • Maximum Acceleration Under Shock Load (During Storage) : 150 m/s² at 11 ms
    • Maximum Acceleration Under Shock Load (During Transport) : 150 m/s² at 11 ms
    • Maximum Acceleration Under Vibrational Stress (During Operation) : 10 m/s² at 13...200 Hz
    • Maximum Acceleration Under Vibratory Load (During Storage) : 10 m/s² at 13...200 Hz
    • Maximum Acceleration Under Vibratory Load (During Transport) : 10 m/s² at 13...200 Hz
    • Maximum Deflection Under Vibratory Load (During Operation) : 1.5 mm at 2...13 Hz
    • Maximum Deflection Under Vibratory Load (During Storage) : 1.5 mm at 2...13 Hz
    • Maximum Deflection Under Vibratory Load (During Transport) : 1.5 mm at 2...13 Hz
    • Permitted Relative Humidity (During Operation) : class 3K5 according to EN 60721-3
    • Permitted Relative Humidity (During Storage) : class 1K5 according to EN 60721-3
    • Permitted Relative Humidity (During Transport) : class 2K5 according to EN 60721-3
    • Supporting Protocol For As-interface Safety At Work : false
    • Supporting Protocol For Data-highway : false
    • Supporting Protocol For Ethernet/Ip : true
    • Supporting Protocol For Interbus-safety : false
    • Supporting Protocol For Tcp/Ip : true
    • With Safety Function Safe Brake Management (Sbc/Sbt) : false
    • With Safety Function Safe Direction (Sdi) : false
    • With Safety Function Safe Operating Stop (Sos) : false
    • With Safety Function Safe Position (Sp) : false
    • With Safety Function Safe Speed Monitor (Ssm) : false
    • With Safety Function Safe Stop 1 (Ss1) : true
    • With Safety Function Safe Torque Off (Sto) : true
    • With Safety Function Safely Limited Position (Slp) : false
    • With Safety Function Safely Limited Speed (Sls) : true
    • With Sft Fct Safe Stop 2 (Ss2) : false
    • Nbr. Of Units In Pkg. : 1
    • Package Weight(Lbs) : 2.793 kg
    • Take-back : No
    • Warranty (In Months) : 18
    • Customs Code : 8504404000
    • Percentage Bio Based Plastic : 18 %
    • Average Percentage Of Bio-based Plastic Content : 18 %
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : -10-50 °C without derating, -10-50 °C without derating, -10-60 °C, -10-60 °C, -10-50 °C without derating, -10-50 °C without derating50-60 °C with derating factor
    • Ambient Air Temperature For Storage : -25-70 °C, -25-70 °C
    • Ambient Air Transport Temperature : -25-70 °C, -25-70 °C
    • Operating Altitude : <= 3280.84 ft (1000 m) without derating, <= 3280.84 ft (1000 m) without derating, 3280.84...6561.68 ft (1000...2000 m) with current derating 1 % per 100 m, <= 3280.84 ft (1000 m) without derating, <= 3280.84 ft (1000 m) without derating
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 2476.4855417721474
    • Circularity Profile : ENVEOLI1512005EN
    • Environmental Disclosure : ENVPEP1512005EN
    • Eu Rohs Directive : Compliant By Exemption
    • Ip Degree Of Protection : IP20
    • Nema Degree Of Protection : NEMA 1
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1512005EN
    • Pep Verification Date : 2024-07-01
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3-EN-2023 06 06
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Phase : 3 phase
    • Product Or Component Type : variable speed drive
    • Range Of Product : Altivar Solar
  • ETIM
    • ETIM 8 : EC001857
    • ETIM 9 : EC001857
  • Output Attributes
    • Discrete Output Type : open collector DQ+ 0-1 kHz 30 V DC 100 mA, open collector DQ- 0-1 kHz 30 V DC 100 mA
    • Relay Output Type : configurable relay logic R1A 1 NO 100000 cyclesconfigurable relay logic R1B 1 NC 100000 cycles, configurable relay logic R1C, configurable relay logic R2A 1 NO 100000 cycles, configurable relay logic R2C
    • Analogue Output Number : 1
    • Analogue Output Type : software-configurable current AQ1 0...20 mA 800 Ohm 10 bitssoftware-configurable voltage AQ1 0...10 V DC 470 Ohm 10 bits
    • Discrete Output Number : 3
    • Maximum Output Frequency : 0.599 kHz
    • Maximum Output Voltage : 500 V
    • Nominal Output Current : 9.5 A
    • Nominal Output Power : 4.0 kW
    • Relay Output Number : 2
  • Surge Protection And Filtering Attributes
    • Emc Filter : Class C2 EMC filter integrated
  • Input Attributes
    • Analogue Input Type : AI1 voltage 0...10 V DC 30 kOhm 10 bits, AI2 bipolar differential voltage +/- 10 V DC 30 kOhm 10 bitsAI3 current 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration) 250 Ohm 10 bits
    • Discrete Input Logic : positive logic (source), negative logic (sink)
    • Discrete Input Type : STO safe torque off, 24 V DC1.5 kOhm, DI1...DI6 logic inputs, 24 V DC 30 V), DI5 programmable as pulse input 0-30 kHz, 24 V DC 30 V)
    • Analogue Input Number : 3
    • Discrete Input Number : 7
    • Number Of Input Phases : 3
  • Specifications
    • Country of Origin : France, Indonesia, United States
    • Depth : 158.0 mm