variable speed drive, Altivar Process ATV600, ATV650, 0.75kW, 1hp, 380...480V, IP55, UL type 12

variable speed drive, Altivar Process ATV600, ATV650, 0.75kW, 1hp, 380...480V, IP55, UL type 12

SQDATV650U07N4U ATV650U07N4U 3606480906961
0.00 / EA
http://schema.org/OutOfStock
  • Connection Type: RJ45 On The Remote Graphic Terminal)Ethernet/Modbus TCP, RJ45 On The Remote Graphic Terminal)Modbus Serial
  • Country of Origin: China
  • Depth: 272 mm
  • Height: 678 mm
  • Net Weight: 10.5 kg
  • Operating Position: Vertical +/- 10 Degree
  • Weight: 10.5 kg
  • Width: 264 mm
QTY
  • Features
  • Specifications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Environmental data
    • Mercury Free : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Minimum Percentage Of Recycled Plastic Content : 0
    • Take-Back : No
    • Global Warming ; Total Life Cycle​ : 2 093 kg CO2 eq.
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 2093.058145081
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : Yes
    • Environmental Disclosure : ENVPEP1508009EN
    • Packaging Without Single Use Plastic : No
    • Scip Number : 787b365c-1873-4754-9a59-b7356bc1cf3b
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Circularity Profile : ENVEOLI1508009EN
    • Eu Rohs Directive : Pro-active compliance (Product out of EU RoHS legal scope)
  • Complementary
    • Prospective Line Isc : 50 kA
    • Network Frequency : 50-60 Hz
    • Analogue Output Type : software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 10 bits || software-configurable current DQ-, DQ+ 30 V DC || software-configurable current DQ-, DQ+ 100 mA
    • Discrete Output Type : relay outputs R1A, R1B, R1C 250 V AC 3000 mA || relay outputs R1A, R1B, R1C 30 V DC 3000 mA || relay outputs R2A, R2C 250 V AC 5000 mA || relay outputs R2A, R2C 30 V DC 5000 mA || relay outputs R3A, R3C 250 V AC 5000 mA || relay outputs R3A, R3C 30 V DC 5000 mA
    • Asynchronous Motor Control Profile : variable torque standard || constant torque standard || optimized torque mode
    • Maximum Switching Current : relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC
    • 4 Quadrant Operation Possible : false
    • Exchange Mode : half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
    • Apparent Power : 0.7 kVA 480 V heavy duty) || 1.1 kVA 480 V normal duty)
    • Phase : 3 phase
    • Net Weight : 10.5 kg
    • With Safety Function Safe Direction (Sdi) : false
    • Type Of Polarization : no impedance
    • Frequency Resolution : analog input 0.012/50 Hz || display unit 0.1 Hz
    • Relay Output Type : configurable relay logic R2 sequence relay NO 100000 cycles || configurable relay logic R3 sequence relay NO 100000 cycles || configurable relay logic R1 fault relay NO/NC 100000 cycles
    • Switching Frequency : 4...12 kHz with derating factor || 2...12 kHz adjustable
    • Maximum Transient Current : 2.3 A 60 s heavy duty) || 2.4 A 60 s normal duty)
    • Analogue Input Number : 3
    • Motor Slip Compensation : can be suppressed || automatic whatever the load || adjustable
    • Discrete Output Number : 0
    • With Safety Function Safe Position (Sp) : false
    • Method Of Access : slave Modbus TCP
    • With Safety Function Safely Limited Position (Slp) : false
    • With Safety Function Safe Operating Stop (Sos) : false
    • Discrete Input Number : 8
    • Local Signalling : 3 LEDs (dual colour) for embedded communication status || 4 LEDs (dual colour) for communication module status || 1 LED (red) for presence of voltage || 3 LEDs for local diagnostic
    • Linearity Error : AO1, AO2 +/- 0.2 % analog output || AI1, AI2, AI3 +/- 0.15 % of maximum value analog input
    • Number Of Addresses : 1-247 Modbus serial
    • With Sft Fct Safe Stop 2 (Ss2) : false
    • With Safety Function Safe Stop 1 (Ss1) : false
    • Width : 264 mm
    • Transmission Rate : 10, 100 Mbits || 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
    • Depth : 272 mm
    • Analogue Input Type : AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits || AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
    • Sampling Duration : 5 ms +/- 1 ms DI5, DI6) - discrete input || 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input || 10 ms +/- 1 ms AO1) - analog output || 2 ms +/- 0.5 ms DI1...DI4) - discrete input
    • Electrical Connection : line side screw terminal 4...6 mm² || motor screw terminal 4...6 mm² || control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16
    • Maximum Output Frequency : 500 kHz
    • With Safety Function Safe Brake Management (Sbc/Sbt) : false
    • Height : 678 mm
    • Acceleration And Deceleration Ramps : linear adjustable separately from 0.01...9999 s
    • Maximum Output Voltage : 480.0 V
    • Base Load Current At High Overload : 1.5 A
    • Transmission Frame : RTU
    • With Safety Function Safe Speed Monitor (Ssm) : false
    • Relay Output Number : 3
    • With Safety Function Safe Torque Off (Sto) : true
    • Data Format : 8 bits, configurable odd, even or no parity
    • Base Load Current At Low Overload : 2.2 A
    • Accuracy : +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output || +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
    • Connector Type : RJ45 on the remote graphic terminal)Modbus serial || RJ45 on the remote graphic terminal)Ethernet/Modbus TCP
    • Input Compatibility : DI5, DI6 discrete input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2 || DI1...DI6 discrete input level 1 PLC IEC 61131-2
    • Permissible Temporary Current Boost : 1.5 x In 60 s heavy duty) || 1.1 x In 60 s normal duty)
    • Analogue Output Number : 2
    • Physical Interface : Ethernet || 2-wire RS 485
    • Minimum Switching Current : relay output R1, R2, R3 5 mA 24 V DC
    • Discrete Input Logic : 16 preset speeds
    • Refresh Time : relay output R1, R2, R3)5 ms +/- 0.5 ms)
    • Enclosure Mounting : wall mounted
    • Isolation : between power and control terminals
    • With Safety Function Safe Programmable Logic : false
    • Brake Chopper Integrated : false
    • Output Voltage : <= power supply voltage
    • Nominal Switching Frequency : 4 kHz
    • Quantity Per Set : 1
    • Braking To Standstill : by DC injection
    • Discrete Input Type : DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V)
    • Protection Type : safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-circuit protection drive || motor phase break drive || overvoltages on the DC bus drive || line supply overvoltage drive || line supply undervoltage drive || line supply phase loss drive || overspeed drive || break on the control circuit drive || thermal protection motor
    • Supply : internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for digital inputs and STO 24 V DC 21-27 V), <200 mA overload and short-circuit protection || external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection
    • With Safety Function Safely Limited Speed (Sls) : false
    • Synchronous Motor Control Profile : synchronous reluctance motor || permanent magnet motor
  • Specifications
    • Country of Origin : China
    • Width : 264 mm
    • Height : 678 mm
    • Weight : 10.5 kg
    • Product Destination : asynchronous motors || synchronous motors
    • Line Current : 1.3 A 480 V normal duty) || 0.9 A 380 V heavy duty) || 0.8 A 480 V heavy duty) || 1.5 A 380 V normal duty)
    • Emc Filter : integrated 50 m IEC 61800-3 category C2 || integrated 150 m IEC 61800-3 category C3
    • Variant : standard version
    • Product Or Component Type : variable speed drive
    • Relative Symmetric Network Frequency Tolerance : 5 %
    • Relative Symmetric Mains Voltage Tolerance : 10 %
    • Communication Port Protocol : Modbus TCP || Modbus serial
    • Nominal Output Current : 2.2 A
    • Product Specific Application : process and utilities
    • Safety Function : STO (safe torque off) SIL 3
    • Maximum Horse Power Rating : 0.5 hp heavy duty || 1 hp normal duty
    • Supply Frequency : 50...60 Hz - 5...5 %
    • Option Card : slot A communication module, PROFINET || slot A communication module, DeviceNet || slot A communication module, Modbus TCP/EtherNet/IP || slot A communication module, CANopen daisy chain RJ45 || slot A communication module, CANopen SUB-D 9 || slot A communication module, CANopen screw terminals || slot A/slot B digital and analog I/O extension module || slot A/slot B output relay extension module || slot A communication module, Ethernet IP/Modbus TCP/MD-Link || communication module, BACnet MS/TP || communication module, Ethernet Powerlink || slot A communication module, Profibus DP V1
    • Degree Of Protection : UL type 12 UL 508C
    • Range Of Product : Altivar Process ATV600
    • Speed Drive Output Frequency : 0.1-500 Hz
    • Ip Degree Of Protection : IP55IEC 60529 || IP55IEC 61800-5-1
    • Motor Power Kw : 0.37 kW heavy duty) || 0.75 kW normal duty)
    • [Us] Rated Supply Voltage : 380...480 V - 15...10 %
    • Mounting Mode : wall mount
    • Type Of Cooling : forced convection
    • Continuous Output Current : 1.5 A 4 kHz heavy duty || 2.2 A 4 kHz normal duty
    • Device Short Name : ATV650
  • Environment
    • Product Certifications : ABS || CSA || TÜV || DNV-GL || UL || ATEX INERIS
    • Maximum Deflection Under Vibratory Load (During Operation) : 1.5 mm at 2...13 Hz
    • Standards : IEC 61800-3 environment 1 category C2 || EN/IEC 61800-3 environment 2 category C3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1 || UL 508C
    • Insulation Resistance : > 1 MOhm 500 V DC for 1 minute to earth
    • Shock Resistance : 15 gn 11 ms IEC 60068-2-27
    • Vibration Resistance : 1 gn (f= 13-200 Hz) conforming to IEC 60068-2-6 || 1.5 mm peak to peak (f= 2-13 Hz) conforming to IEC 60068-2-6
    • Regulation Loop : adjustable PID regulator
    • Permitted Relative Humidity (During Operation) : class 3K5 according to EN 60721-3
    • Operating Altitude : 1000...4800 m with current derating 1 % per 100 m || <= 3280.84 ft (1000 m) without derating
    • Overvoltage Category : III
    • Environmental Class (During Operation) : class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3
    • Maximum Acceleration Under Shock Impact (During Operation) : 150 m/s² at 11 ms
    • Electromagnetic Compatibility : radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 || conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 || electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
    • Ambient Air Temperature For Operation : 40-50 °C (with derating factor) || -15-40 °C (without derating)
    • Marking : CE
    • Maximum Acceleration Under Vibrational Stress (During Operation) : 10 m/s² at 13...200 Hz
    • Pollution Degree : 2 IEC 61800-5-1
    • Noise Level : 52 dB
    • Ambient Air Temperature For Storage : -40-70 °C
    • Relative Humidity : 5-95 % without condensation IEC 60068-2-3
    • Operating Position : vertical +/- 10 degree
    • Maximum Thdi : <48 % full load IEC 61000-3-12
    • Ambient Air Transport Temperature : -40-70 °C