variable speed drive, Altivar Process ATV900, ATV930, 7.5kW, 10hp, 500 to 690V, IP00

vsd ATV930 10HP 500v/690v

SQDATV930U75Y6 ATV930U75Y6 3606481325280
3134.68 / EA
http://schema.org/OutOfStock
QTY
  • Features
  • Specifications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • Maximum Switching Current : relay output R1 resistive, cos phi = 1 3 A 250 V AC, relay output R1 resistive, cos phi = 1 3 A 30 V DC, relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC, relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC, relay output R2, R3 resistive, cos phi = 1 5 A 250 V AC, relay output R2, R3 resistive, cos phi = 1 5 A 30 V DC, relay output R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC, relay output R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC
    • Maximum Transient Current : 10.8 A 60 s heavy duty), 11.4 A 60 s normal duty)
    • UE Rated Operational Voltage : 500 V 5.5 kW 7.5 hp normal duty, 500 V 4.0 kW 5 hp heavy duty, 690 V 7.5 kW 10 hp normal duty, 690 V 5.5 kW 7.5 hp heavy duty
    • Brake Chopper Integrated : true
    • Maximum Associated Fuse Rating : 20.0 A
    • Maximum Input Current Per Phase : 10.5 A
    • Maximum Output Voltage : 690.0 V
    • Minimum Switching Current : relay output R1, R2, R3 5 mA 24 V DC
    • US Rated Supply Voltage : 500...690 V - 15...10 %
    • Maximum Acceleration Under Shock Impact During Operation : 150 m/s² at 11 ms
    • Maximum Acceleration Under Shock Load During Storage : 150 m/s² at 11 ms
    • Maximum Acceleration Under Shock Load During Transport : 150 m/s² at 11 ms
    • Maximum Acceleration Under Vibrational Stress During Operation : 10 m/s² at 13...200 Hz
    • Maximum Acceleration Under Vibratory Load During Storage : 10 m/s² at 13...200 Hz
    • Maximum Acceleration Under Vibratory Load During Transport : 10 m/s² at 13...200 Hz
    • Maximum Deflection Under Vibratory Load During Operation : 1.5 mm at 2...13 Hz
    • Maximum Deflection Under Vibratory Load During Storage : 1.5 mm at 2...13 Hz
    • Maximum Deflection Under Vibratory Load During Transport : 1.5 mm at 2...13 Hz
  • Important Information Attributes
    • Persona Type Ids : EU, OM, OM8, SI
    • Persona Type Names : End User, Original Equipment Manufacturer, OEM - Control Panelbuilder, System Integrator
    • Apparent Power : 12.5 kVA 690 V normal duty), 9.6 kVA 690 V heavy duty)
    • Asynchronous Motor Control Profile : optimized torque mode, constant torque standard, variable torque standard
    • Electromagnetic Compatibility : electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2, radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3, electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4, 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5, conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
    • Encoder Protocol : 1 Vpp, EnDat 2.2, resolver, RS 422, SSI 24V, SSI 5V, TTL/HTL
    • Line Current : 10.4 A 500 V normal duty), 7.9 A 500 V heavy duty), 10.5 A 690 V normal duty), 8.0 A 690 V heavy duty)
    • Linearity Error : AI1, AI2, AI3 +/- 0.15 % of maximum value analog input, AQ1, AQ2 +/- 0.2 % analog output
    • Motor Power KW : 5.5 kW normal duty, 4.0 kW heavy duty
    • Motor Slip Compensation : automatic whatever the load, not available in permanent magnet motor law, can be suppressed, adjustable
    • Power Dissipation In W : forced convection 136 W 500 V 4 kHz, natural convection 88 W 500 V 4 kHz
    • Protection Type : thermal protection motor, safe torque off motor, motor phase break motor, thermal protection drive, safe torque off drive, overheating drive, overcurrent between output phases and earth drive, overload of output voltage drive, short-circuit protection drive, motor phase break drive, overvoltages on the DC bus drive, line supply overvoltage drive, line supply undervoltage drive, line supply phase loss drive, overspeed drive, break on the control circuit drive
    • Sampling Duration : 2 ms +/- 0.5 ms DI1...DI8) - discrete input, 5 ms +/- 1 ms DI7, DI8) - pulse input, 1 ms +/- 1 ms AI1, AI2, AI3) - analog input, 5 ms +/- 1 ms AQ1, AQ2) - analog output
    • Switching Frequency : 2...8 kHz adjustable, 4...8 kHz with derating factor
    • Synchronous Motor Control Profile : permanent magnet motor, synchronous reluctance motor
    • Transmission Rate : 10/100 Mbit/s Ethernet IP/Modbus TCP, 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
    • Variant : with braking chopper, standard version
    • Environmental Class During Storage : class 1C3 according to EN 60721-3-1, class 1S2 according to EN 60721-3-1
    • Environmental Class During Transport : class 2C3 according to EN 60721-3-2, class 2S1 according to EN 60721-3-2
    • Carbon Footprint Of The Distribution Phase A4 : 8.184404244492645, 8 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 77.15005420482038, 77 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 14 kg CO2 eq., 14.172122696299526
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 457 kg CO2 eq., 456.960334455971
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 3 863 kg CO2 eq., 3863.3064710552408
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-12-19
    • Device Type : Variable speed drive - VSD Compacts
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : IDIBS
    • Average Life Duration : 10 year(s)
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1704001EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : No
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status : Pro-active compliance (Product out of EU RoHS legal scope)
    • ROHS EUR Full Compliance Status Id : PRO_ACTIVE_COMPLIANCE
    • China ROHS In Scope : Yes
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : YES_SSI2
    • Return Indicator : Y
    • WD Status : 1 - GSC certified
    • Dangerous Goods Code : LITHIUM METAL BATTERIES IN EQUIP. BUTTON CELL-BAT EXEMPT
    • Function Option Id : ADVANCED
    • Function Option : Advanced
    • Market Segmentation Id : INDUSTRIAL
    • Market Segmentation : Industrial
    • 1 Phase Low Current Possible : false
    • 4 Quadrant Operation Possible : true
    • Application In Domestic And Commercial Area Permitted : false
    • Assembly Style : enclosed
    • Base Load Current At High Overload : 7.2 A
    • Base Load Current At Low Overload : 9.5 A
    • Braking To Standstill : by DC injection
    • Computer Port : true
    • Data Format : 8 bits, configurable odd, even or no parity Modbus serial
    • Design Of Frequency Changer : U converter
    • Exchange Mode : half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
    • Housing Material : sheet steel
    • Isolation : between power and control terminals
    • Maximum Associated Fuse Rating : 20.0 A
    • Maximum Input Current Per Phase : 10.5 A
    • Method Of Access : slave Modbus TCP
    • Noise Level : 58 dB 86/188/EEC
    • Nominal Switching Frequency : 4 kHz
    • Number Of Addresses : 1-247 Modbus serial
    • Operating Element Present : true
    • Optical Interface Present : false
    • Package Weight Lbs : 42.000 kg
    • Phase : 3 phase
    • Power Loss Per Device Current Dependent : 211.0 W
    • Power Loss Static Current Independent : 41.0 W
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : variable speed drive
    • Product Specific Application : process for industrial
    • Range Of Product : Altivar Process ATV900
    • Refresh Time : relay output R1, R2, R3)5 ms +/- 0.5 ms)
    • Relative Symmetric Mains Voltage Tolerance : 10 %
    • Relative Symmetric Network Frequency Tolerance : 5 %
    • Returnability : Yes
    • Supporting Protocol For As Interface Safety At Work : false
    • Supporting Protocol For Asi : false
    • Supporting Protocol For Bacnet : false
    • Supporting Protocol For Can : true
    • Supporting Protocol For Data Highway : false
    • Supporting Protocol For Devicenet : false
    • Supporting Protocol For Devicenet Safety : false
    • Supporting Protocol For Ethernet Ip : true
    • Supporting Protocol For Foundation Fieldbus : false
    • Supporting Protocol For Interbus : false
    • Supporting Protocol For Knx : false
    • Supporting Protocol For Lon : false
    • Supporting Protocol For Modbus : true
    • Supporting Protocol For Other Bus Systems : false
    • Supporting Protocol For Profibus : true
    • Supporting Protocol For Profinet Cba : true
    • Supporting Protocol For Profinet Io : true
    • Supporting Protocol For Profisafe : false
    • Supporting Protocol For Safetybus P : false
    • Supporting Protocol For Sercos : false
    • Supporting Protocol For Suconet : false
    • Supporting Protocol For TCP IP : true
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 4 420 kg CO2 eq.
    • Type Of Polarization : no impedance Modbus serial
    • Volume Of Cooling Air : 330 m3/h
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • With Safety Function Safe Programmable Logic : false
    • EMC Limit Value Complied : true
    • Permitted Relative Humidity During Transport : class 2K5 according to EN 60721-3
    • With Safety Function Safe Brake Management Sbc Sbt : true
    • With Safety Function Safe Direction SDI : false
    • With Safety Function Safe Operating Stop Sos : false
    • With Safety Function Safe Position Sp : false
    • With Safety Function Safe Speed Monitor Ssm : false
    • With Safety Function Safe Stop 1 SS1 : true
    • With Safety Function Safe Torque Off Sto : true
    • With Safety Function Safely Limited Position Slp : false
    • With Safety Function Safely Limited Speed Sls : true
    • With Sft Fct Safe Stop 2 Ss2 : false
    • Relationship Type : Compatible relationship
    • Application In Industrial Area Permitted : true
    • Supporting Protocol For Interbus Safety : false
    • Pep Code : ENVPEP1704001EN
    • Pep Verification Date : 2024-11-01
    • PCR Version : PCR-4-ed4-EN-2021 09 06
    • PSR Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
    • Functional Unit Description : To adapt the speed and torque of synchronous, asynchronous or reluctance motor to the machine's operating point for 22 kW for heavy duty electric motors for fluid management and industrial applications in IP20/UL type 1 conditions, at 600V rated 3-phases voltage supply. Calculation of the environmental impacts is based on 10 years of product service lifetime. The usage profile taken into account is 80% uptime in use phase at 75% loading rate and 20% uptime in stand by phase.
    • Functional Unit Unit : Unit
    • Product Kit Identifier : N
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : -15-50 °C (without derating), -15-50 °C (without derating), 50-60 °C (with derating factor)
    • EU ROHS Directive : Compliant By Exemption​, Pro-active compliance (Product out of EU RoHS legal scope)
    • Operating Altitude : <= 3280.84 ft (1000 m) without derating, <= 3280.84 ft (1000 m) without derating, 1000...4800 m with current derating 1 % per 100 m
    • Environmental Class During Operation : class 3C3 according to IEC 60721-3-3, class 3S3 according to IEC 60721-3-3
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 4419.773386656824
    • Ambient Air Transport Temperature : -40-70 °C
    • Circularity Profile : ENVEOLI1704001EN
    • Environmental Disclosure : ENVPEP1704001EN
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Permitted Relative Humidity During Operation : class 3K5 according to EN 60721-3
    • Permitted Relative Humidity During Storage : class 1K5 according to EN 60721-3
    • Pep Code : ENVPEP1704001EN
    • Pep Verification Date : 2024-11-01
    • PCR Version : PCR-4-ed4-EN-2021 09 06
    • PSR Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Phase : 3 phase
    • Product Or Component Type : variable speed drive
    • Range Of Product : Altivar Process ATV900
  • Output Attributes
    • Analogue Output Type : software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits, software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
    • Continuous Output Current : 7.2 A 4 kHz heavy duty, 9.5 A 4 kHz normal duty
    • Discrete Output Type : logic output DQ+ 0-1 kHz <= 30 V DC 100 mA, programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA, logic output DQ- 0-1 kHz <= 30 V DC 100 mA
    • Relay Output Type : configurable relay logic R1 fault relay NO/NC 100000 cycles, configurable relay logic R2 sequence relay NO 1000000 cycles, configurable relay logic R3 sequence relay NO 1000000 cycles
    • Maximum Output Voltage : 690.0 V
    • Relay Output Number : 3
  • Input Attributes
    • Analogue Input Type : AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits, AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
    • Discrete Input Type : DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm, DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V), STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
    • Input Compatibility : DI1...DI8 discrete input level 1 PLC IEC 61131-2, DI7, DI8 pulse input level 1 PLC IEC 65A-68, STOA, STOB discrete input level 1 PLC IEC 61131-2
    • Number Of Input Phases : 3
  • Batteries & Runtime Attributes
    • Removable Battery : YES