Schneider Electric at Mayer

Enclosed switch disconnector, TeSys Control, for ON/emergency stop, 32A, IP65, compact size

Enclosed switch disconnector, TeSys Control, for ON/emergency stop, 32A, IP65, compact size

SQDVCFN40GE VCFN40GE 3389110897722
246.96 / EA
http://schema.org/OutOfStock
  • Depth: 106 mm
  • Warranty Length: 18 mth
TeSys enclosed starter with switch disconnector, 3 poles, Ithe 32A 690V, for main and emergency stop switching in motor applications up to 15kW@400V AC-23. Enclosure providing IP55 protection, yellow cover fitted with a red rotary handle and I/O marking, padlockable (padlocks not included). It includes a 3-pole Vario switch body V2 with no possibility to have add-on module attachments. Surface mounting enclosure with screw fixing, 2 knock-outs for cable glands on top and bottom, sealable cover. It conforms to IEC 60947-4-1.
QTY
  • Product Description
  • Features
  • Specifications
TeSys enclosed starter with switch disconnector, 3 poles, Ithe 32A 690V, for main and emergency stop switching in motor applications up to 15kW@400V AC-23. Enclosure providing IP55 protection, yellow cover fitted with a red rotary handle and I/O marking, padlockable (padlocks not included). It includes a 3-pole Vario switch body V2 with no possibility to have add-on module attachments. Surface mounting enclosure with screw fixing, 2 knock-outs for cable glands on top and bottom, sealable cover. It conforms to IEC 60947-4-1.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Physical Attributes
    • Handle Color : red
    • Handle Front Plate Color : yellow
  • Complementary Attributes
    • Rated Operational Power In W : 15 kW 400 V AC-23), 11 kW 400 V AC-3)
    • Rated Conditional Short Circuit Current : 10 kA 400 V
    • Icw Rated Short Time Withstand Current : 960 A 400 V 1 s
    • Ue Rated Operational Voltage : 690 V AC
    • Uimp Rated Impulse Withstand Voltage : 8 kV
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Mechanical Robustness : vibrations 10...150 Hz 1 gn) IEC 60068-2-6, shocks 11 ms 30 Gn) IEC 60068-2-27
    • Carbon Footprint Of The Distribution Phase A4 : 0.09977178507571986, 0.1 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 1 kg CO2 eq., 1.1202873398259132
    • Carbon Footprint Of The Installation Phase A5 : 0.08096519078500214, 0.1 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 3 kg CO2 eq., 2.6930009789520537
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 13 kg CO2 eq., 13.432378470046519
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-12-03
    • Return Indicator : N
    • Stocking Flag : Y
    • Stock Policy : 2
    • Device Type : LV equipment - LV switch - disconnector
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 15 year(s)
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant
    • Rohs Eur Conformity Date : 1936
    • Rohs Eur Full Compliance Status : Compliant
    • China Rohs In Scope : No
    • China Rohs Label : 1
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 2
    • Tier : 2
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Base Dimension : 60 x 60 mm
    • Compatibility Code : enclosed switch disconnector
    • Control Type : rotary handle
    • Device Short Name : VCFN
    • Fire Resistance : 960 °C IEC 60595-2-1
    • Intermittent Duty Class : 30
    • Making Capacity : 400 A 400 V AC-21A
    • Marking : 0 - 1
    • Performance Level : standard
    • Poles Description : 3P
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Name : TeSys Mini-VARIO
    • Product Or Component Type : emergency stop switch disconnector
    • Protective Treatment : TC
    • Range : TeSys
    • Returnability : No
    • Rotary Handle Padlocking : 1 to 3 padlocks 4-8 mm
    • Software Version : v6.1
    • Suitability For Isolation : yes
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 17 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Handle Color : red
    • Handle Front Plate Color : yellow
    • Icw Rated Short Time Withstand Current : 960 A 400 V 1 s
    • Ithe Conventional Enclosed Thermal Current : 32 A
    • Warranty In Months : 18
    • Pep Code : ENVPEP2211019EN
    • Database Version : 2023-02
    • Pep Verification Date : 2025-08-05
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional Unit Description : Turn off all or part of an installation by separating the installation or part of the installation of all electrical energy or earth, for safety reasons with a rated voltage U, and rated current In ensuring isolation characterised by a rated voltage Ui, and if applicable the specific specifications, according to the appropriate use scenario, and during the reference service life of the product of 20 years.
    • Functional Unit Quantity : 1
    • Functional Unit Unit : unit
    • Reference Lifetime In Y2 : 20
    • Energy Model Manufacturing A1 A3 2 : Czech Republic, CZ
    • Energy Model Installation A5 2 : Electricity Mix; Low voltage; 2018; France, FR
    • Energy Model Use B6 2 : Electricity Mix; Low voltage; 2018; France, FR
    • Energy Model End Of Life C1 C4 2 : Electricity Mix; Low voltage; 2018; France, FR
    • Recyclability Potential In 2 : 20
    • Offer Owner Code : 190788
    • Pn : 1
    • Height Nominal : 131 mm
    • Width Nominal : 82.5 mm
    • Certificate Agency : IEC 60947-4-1
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 17.426403764685208
    • Ambient Air Temperature For Operation : -20-50 °C
    • Environmental Disclosure : ENVPEP2211019EN
    • Eu Rohs Directive : Compliant
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2211019EN
    • Pep Verification Date : 2025-08-05
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : emergency stop switch disconnector
  • ETIM
    • ETIM 8 : EC000216
    • ETIM 9 : EC000216
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Country of Origin : Brazil, Czechia, France
    • Depth : 106 mm