Contactor, Tesys N Contactors, nonreversing, 3P, 3phase, 45A, 25HP at 460VAC, NEMA size 2, 120VAC 50/60Hz coil, open

NEMA SZ 2 CONTACTOR 3P 120VAC

SQDT02DN13G7 T02DN13G7 3606480575068
465.11 / EA
http://schema.org/OutOfStock
  • Depth: 4.72 in
TeSys N contactors and starters conform to NEMA ICS2 standards. The NEMA size is printed directly on the face of the contactor. This 3 pole NEMA size 2 nonreversing contactor mounts on 35mm DIN rail and has a 45 amperage continuous current rating. This contactor has 3 HP at 115 VAC and 7.5 HP at 230 VAC single phase ratings. The contactor also has ratings of 10 HP at 200, 15 HP at 230 VAC and 25 HP at 460 and 575 VAC poly phase. The nonreversing contactor is wired for common control with a 120 VAC 50/60 Hz replaceable coil. Contactor has 1 normally open and 1 normally closed auxiliary contact. This contactor is not in an enclosure. This contactor is 5.47 inches tall, 2.16 inches wide and 4.72 inches deep. It weighs 2.08 lbs. The screw clamp terminals will accept power wires from 16 AWG to 4 AWG and control wires from 16 AWG to 12 AWG. This TeSys N contactor is UL listed and CSA Certified.
QTY
  • Product Description
  • Features
  • Specifications
TeSys N contactors and starters conform to NEMA ICS2 standards. The NEMA size is printed directly on the face of the contactor. This 3 pole NEMA size 2 nonreversing contactor mounts on 35mm DIN rail and has a 45 amperage continuous current rating. This contactor has 3 HP at 115 VAC and 7.5 HP at 230 VAC single phase ratings. The contactor also has ratings of 10 HP at 200, 15 HP at 230 VAC and 25 HP at 460 and 575 VAC poly phase. The nonreversing contactor is wired for common control with a 120 VAC 50/60 Hz replaceable coil. Contactor has 1 normally open and 1 normally closed auxiliary contact. This contactor is not in an enclosure. This contactor is 5.47 inches tall, 2.16 inches wide and 4.72 inches deep. It weighs 2.08 lbs. The screw clamp terminals will accept power wires from 16 AWG to 4 AWG and control wires from 16 AWG to 12 AWG. This TeSys N contactor is UL listed and CSA Certified.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Conformance Attributes
    • Product Certifications : UL Listed, CSA
  • Complementary Attributes
    • Maximum Horse Power Rating : 10 hp 200 V AC, 15 hp 230 V AC, 25 hp 460 V AC, 25 hp 575 V AC
    • Control Circuit : common control circuit
    • Line Rated Current : 45 A
    • Uc Control Circuit Voltage : 120 V AC
    • Ue Rated Operational Voltage : 600 V AC
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-03-26
    • Global Commercial Status : Commercialised
    • Return Indicator : Y
    • Stocking Flag : Y
    • Stock Policy : 1
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Legacy Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : Outside of Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI110229EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant
    • Rohs Eur Conformity Date : 1904
    • Rohs Eur Full Compliance Status : Compliant
    • China Rohs In Scope : No
    • China Rohs Label : 1
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 2
    • Tier : 2
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Contactor Application : non-reversing
    • Control Circuit : common control circuit
    • Electrical Connection : screw clamp terminals
    • Energy Efficiency Optimized : False
    • Phase : 3 phase
    • Poles Description : 3P
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : contactor
    • Range Of Product : TeSys N
    • Returnability : Yes
    • Sustainable Packaging : Yes
    • Warranty In Months : 18
    • Pep Code : ENVPEP110229EN
    • Offer Owner Code : 190788
    • Height Nominal : 5.47 in
    • Width Nominal : 2.16 in
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Take Back : Nej
    • Recycled Metal Content At Cr Level : 0 %
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Circularity Profile : ENVEOLI110229EN
    • Environmental Disclosure : ENVPEP110229EN
    • Eu Rohs Directive : Compliant
    • Nema Degree Of Protection : not rated (open device)
    • Nema Size : 2
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP110229EN
  • General Attributes
    • Phase : 3 phase
    • Product Or Component Type : contactor
    • Range Of Product : TeSys N
  • ETIM
    • ETIM 8 : EC000010
    • ETIM 9 : EC000010
  • Specifications
    • Depth : 4.72 in