Control relay, TeSys K, 4NO, 600V, 125VDC standard coil

CONTROL RELAY 600VAC 10AMP IEC

SQDCA3KN40GD CA3KN40GD 3389110484724
81.05 / EA
http://schema.org/OutOfStock
  • Country of Origin: Indonesia
  • Depth: 57 mm
  • Height: 58 mm
  • Net Weight: 0.225 kg
  • Warranty Length: 18 mth
  • Weight: 0.225 kg
  • Width: 45 mm
TeSys K IEC industrial control relays are used in industrial control circuits. This Type K control relays has 4 normally open contacts. The contacts have AC-15 and DC13 contact ratings. Type K control relays can be mounted on 35mm DIN rail or can be mounted directed to a panel. The relay has a 125 VDC coil. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The relay is 2.28 inches tall, 1.77 inches wide and 2.24 inches deep. It weighs 0.50 lbs. This control relay is UL Listed and CSA certified.
QTY
  • Product Description
  • Features
  • Specifications
TeSys K IEC industrial control relays are used in industrial control circuits. This Type K control relays has 4 normally open contacts. The contacts have AC-15 and DC13 contact ratings. Type K control relays can be mounted on 35mm DIN rail or can be mounted directed to a panel. The relay has a 125 VDC coil. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The relay is 2.28 inches tall, 1.77 inches wide and 2.24 inches deep. It weighs 0.50 lbs. This control relay is UL Listed and CSA certified.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Environment
    • Product Certifications : CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
    • Mechanical Robustness : vibrations contactor open2 Gn, 5...300 Hz IEC 60068-2-6 || vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 || shocks contactor open10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed15 Gn for 11 ms IEC 60068-2-27
    • Ambient Air Temperature For Operation : -25-50 °C
    • Standards : EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
    • Flame Retardance : V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
    • Ambient Air Temperature For Storage : -50-80 °C
    • Protective Treatment : TC IEC 60068
    • Ip Degree Of Protection : IP2X
    • Operating Altitude : 6561.68 ft (2000 m) without derating
  • Contractual warranty
    • Warranty : 18 months
  • Environmental data
    • Packaging Made With Recycled Cardboard : Yes
    • Environmental Disclosure : ENVPEP1503003
    • Packaging Without Single Use Plastic : Yes
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Circularity Profile : ENVEOLI1503003
    • Take-Back : No
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 120.47645292809696
  • Complementary
    • Minimum Switching Current : 5 mA
    • Height : 58 mm
    • Control Circuit Voltage Limits : operational: 0.8...1.15 Uc (at <50 °C) || drop-out: 0.1...0.75 Uc (at <50 °C)
    • Non Overlap Distance : 0.5 mm
    • [Ith] Conventional Free Air Thermal Current : 10 A (at 50 °C)
    • Mounting Support : plate || rail
    • Immunity To Microbreaks : 2 ms
    • Hold-In Power Consumption In W : 3-3 W 20 °C
    • Insulation Resistance : > 10 MOhm
    • Irms Rated Making Capacity : 110 A IEC 60947
    • Associated Fuse Rating : 10 A gG conforming to IEC 60947 || 10 A gG conforming to VDE 0660
    • Net Weight : 0.225 kg
    • Connections - Terminals : screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible with cable end || screw clamp terminals 2 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-1.5 mm²flexible with cable end || screw clamp terminals 2 0.34-1.5 mm²flexible without cable end
    • Minimum Switching Voltage : 17 V
    • Maximum Operating Rate : 10000 cyc/h
    • Tightening Torque : 1.3 N.m screw clamp terminals flat Ø 6 mm || 1.3 N.m screw clamp terminals Philips No 2 6 mm || 1.3 N.m screw clamp terminals pozidriv No 2
    • Mechanical Durability : 20 Mcycles
    • Inrush Power In W : 3-3 W 20 °C)
    • Operating Time : 10 ms coil de-energisation and NO opening || 30...40 ms coil energisation and NO closing
    • Width : 45 mm
    • Depth : 57 mm
    • [Ui] Rated Insulation Voltage : 690 V IEC 60947 || 750 V VDE 0110 group C || 690 V BS 5424 || 600 V CSA C22.2 No 14
    • Heat Dissipation : 3-3 W
  • Specifications
    • Country of Origin : Indonesia
    • Width : 45 mm
    • Height : 58 mm
    • Weight : 0.225 kg
    • [Ue] Rated Operational Voltage : <= 690 V <= 400 Hz
    • Control Circuit Type : DC standard
    • [Uc] Control Circuit Voltage : 125 V DC
    • Contactor Application : control circuit
    • Product Or Component Type : control relay
    • Product Name : TeSys CAK
    • Range : TeSys
    • Pole Contact Composition : 4 NO
    • Utilisation Category : AC-15 || DC-13
    • Device Short Name : CA3K