Control relay, TeSys K, 3 NO + 1 NC, lt or eq to 690V, 24VDC standard coil

Control relay, TeSys K, 3 NO + 1 NC, lt or eq to 690V, 24VDC standard coil

SQDCA3KN313BD CA3KN313BD 3389110241778
83.02 / EA
http://schema.org/OutOfStock
  • Warranty Length: 18 mth
TeSys K control relay, 4 contacts (3NO + 1NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13. It provides a 24V DC control circuit with no inrush consumption, connection by spring terminals. For high operating rates until 180 cycles/min and ambient temperature -25/+50°C, it procures high reliability and durability. Compact (45mm width), for clipping on 35mm DIN rail or fixing by screw. Multi standards certified (IEC, UL, CSA, CCC, EAC).
QTY
  • Product Description
  • Features
  • Specifications
TeSys K control relay, 4 contacts (3NO + 1NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13. It provides a 24V DC control circuit with no inrush consumption, connection by spring terminals. For high operating rates until 180 cycles/min and ambient temperature -25/+50°C, it procures high reliability and durability. Compact (45mm width), for clipping on 35mm DIN rail or fixing by screw. Multi standards certified (IEC, UL, CSA, CCC, EAC).
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Conformance Attributes
    • Standards : EN/IEC 60947-5-1, GB/T 14048.5, UL 60947-5-1, CSA C22.2 No 60947-5-1, JIS C8201-5-1
  • Complementary Attributes
    • Control Circuit Voltage Limits : operational: 0.8...1.15 Uc (at <50 °C), drop-out: 0.1...0.75 Uc (at <50 °C)
    • UE Rated Operational Voltage : <= 690 V <= 400 Hz, <= 690 V <= 400 Hz
    • UI Rated Insulation Voltage : 690 V IEC 60947, 750 V VDE 0110 group C, 690 V BS 5424, 600 V CSA C22.2 No 14
    • Control Circuit Type : DC standard
    • IRMS Rated Making Capacity : 110 A IEC 60947
    • Maximum Operating Rate : 10000 cyc/h
    • Minimum Switching Current : 5 mA
    • Minimum Switching Voltage : 17 V
    • UC Control Circuit Voltage : 24 V DC
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SI
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Associated Fuse Rating : 10 A gG conforming to IEC 60947, 10 A gG conforming to VDE 0660
    • Flame Retardance : V1 conforming to UL 94, requirement 2 conforming to NF F 16-101, requirement 2 conforming to NF F 16-102
    • Mechanical Robustness : vibrations contactor open2 Gn, 5...300 Hz IEC 60068-2-6, vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6, shocks contactor open10 Gn for 11 ms IEC 60068-2-27, shocks contactor closed15 Gn for 11 ms IEC 60068-2-27
    • Operating Time : 10 ms coil de-energisation and NO opening, 30...40 ms coil energisation and NO closing, 15 ms coil de-energisation and NC closing, 25...35 ms coil energisation and NC opening
    • Carbon Footprint Of The Distribution Phase A4 : 0.08748530601806714, 0.1 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.4 kg CO2 eq., 0.37238162354829996
    • Carbon Footprint Of The Installation Phase A5 : 0.013472865458001313, 0 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 1 kg CO2 eq., 1.2191683759210354
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 117 kg CO2 eq., 116.84560644093847
    • Connections Terminals : spring terminals 1 0.75-1.5 mm²solid, spring terminals 1 0.75-1.5 mm²flexible without cable end
    • Add Ons : LA1KN403, LA1KN223, LA1KN313
    • Auxiliaries : LA4KE1B, LA4KC1B
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-09
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1503003
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant
    • ROHS EUR Full Compliance Status : Compliant
    • ROHS EUR Full Compliance Status Id : COMPLIANT
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • WD Status : 1 - GSC certified
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Compatibility Code : CA3K
    • Contactor Application : control circuit
    • Device Short Name : CA3K
    • Heat Dissipation : 3-3 W
    • Hold In Power Consumption In W : 3-3 W 20 °C
    • Immunity To Microbreaks : 2 ms
    • Inrush Power In W : 3-3 W 20 °C)
    • Insulation Resistance : > 10 MOhm
    • Non Overlap Distance : 0.5 mm
    • Package Weight Lbs : 224.0 g
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : control relay
    • Protective Treatment : TC IEC 60068
    • Range : TeSys
    • Range Of Product : TeSys K control relay
    • Returnability : Yes
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 119 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • ITH Conventional Free Air Thermal Current : 10 A (at 50 °C)
    • Relationship Type : Compatible relationship
    • Pep Code : ENVPEP1503003
    • Pep Verification Date : 2025-11-21
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed3-2023 06 06
    • Type Of Verification For The Pep : Independent internal review
    • Functional Unit Description : Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
    • Functional Unit Unit : unit
    • Product Kit Identifier : N
  • Environment Attributes Main
    • EU ROHS Directive : Compliant​, Compliant
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Reach Free SHVC : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : X
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 118.53811461188388
    • Circularity Profile : ENVEOLI1503003
    • Environmental Disclosure : ENVPEP1503003
    • Operating Altitude : 6561.68 ft (2000 m) without derating
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Free Of SVHC : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1503003
    • Pep Verification Date : 2025-11-21
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed3-2023 06 06
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : control relay
    • Range Of Product : TeSys K control relay
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months