Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 6A, 1 NO aux., 200 to 208VAC coil

CONTACTOR 600VAC 6AMP IEC +OPT

SQDLC1K0610L7 LC1K0610L7 3389110703931
68.70 / EA
http://schema.org/OutOfStock
  • Warranty Length: 18 mth
TeSys K contactor, 3 poles (3NO), for motor control applications up to 6A/690V AC-3 (2.2kW@400V). It provides a 200-208V 50/60Hz AC coil, 1NO built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC).
QTY
  • Product Description
  • Features
  • Specifications
TeSys K contactor, 3 poles (3NO), for motor control applications up to 6A/690V AC-3 (2.2kW@400V). It provides a 200-208V 50/60Hz AC coil, 1NO built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC).
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Conformance Attributes
    • Standards : EN/IEC 60947-4-1, GB/T 14048.4, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1, IEC 60335-1:Clause 30.2, IEC 60335-2-40:Annex JJ, UL 60335-2-40:Annex JJ
  • Complementary Attributes
    • Control Circuit Voltage Limits : operational: 0.8...1.15 Uc (at <50 °C), drop-out: >= 0.20 Uc (at <50 °C)
    • IRMS Rated Making Capacity : 110 A AC for power circuit conforming to IEC 60947, 110 A AC for signalling circuit conforming to IEC 60947
    • Rated Breaking Capacity : 110 A at 220...230 V conforming to IEC 60947, 110 A at 380...400 V conforming to IEC 60947, 110 A at 415 V conforming to IEC 60947, 110 A at 440 V conforming to IEC 60947, 80 A at 500 V conforming to IEC 60947, 70 A at 660...690 V conforming to IEC 60947
    • ICW Rated Short Time Withstand Current : 90 A 50 °C - 1 s for power circuit, 85 A 50 °C - 5 s for power circuit, 80 A 50 °C - 10 s for power circuit, 60 A 50 °C - 30 s for power circuit, 45 A 50 °C - 1 min for power circuit, 40 A 50 °C - 3 min for power circuit, 20 A 50 °C - >= 15 min for power circuit, 80 A - 1 s for signalling circuit, 90 A - 500 ms for signalling circuit, 110 A - 100 ms for signalling circuit
    • IE Rated Operational Current : 6 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 6 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
    • UE Rated Operational Voltage : power circuit <= 690 V AC <= 400 Hz, signalling circuit <= 690 V AC <= 400 Hz
    • UI Rated Insulation Voltage : power circuit 600 V UL 508, power circuit 690 V IEC 60947-4-1, signalling circuit 690 V IEC 60947-4-1, signalling circuit 690 V IEC 60947-5-1, signalling circuit 600 V UL 508, power circuit 600 V CSA C22.2 No 14, signalling circuit 600 V CSA C22.2 No 14
    • Control Circuit Type : AC 50/60 Hz
    • Maximum Motor Phase Current : 6 A
    • Maximum Operating Rate : 3600 cyc/h
    • Minimum Switching Current : 5 mA for signalling circuit
    • Minimum Switching Voltage : 17 V for signalling circuit
    • UC Control Circuit Voltage : 200...208 V AC 50/60 Hz
    • UIMP Rated Impulse Withstand Voltage : 8 kV
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SI
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Associated Fuse Rating : 25 A gG at <= 440 V for power circuit, 25 A aM for power circuit, 10 A gG for signalling circuit conforming to IEC 60947, 10 A gG for signalling circuit conforming to VDE 0660
    • Electrical Durability : 1.3 Mcycles 6 A AC-3 <= 440 V, 1.3 Mcycles 6 A AC-3e <= 440 V, 0.05 Mcycles 36 A AC-4 <= 440 V
    • Flame Retardance : V1 conforming to UL 94, requirement 2 conforming to NF F 16-101, requirement 2 conforming to NF F 16-102
    • Insulation Resistance : > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
    • Mechanical Robustness : shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27, shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27, shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27, shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27, shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27, shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27, vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6, vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6
    • Motor Power KW : 1.5 kW 220...230 V AC 50/60 Hz AC-3, 2.2 kW 380...415 V AC 50/60 Hz AC-3, 3 kW 440/690 V AC 50/60 Hz AC-3, 1.5 kW 220...230 V AC 50/60 Hz AC-3e, 2.2 kW 380...415 V AC 50/60 Hz AC-3e, 3 kW 440/690 V AC 50/60 Hz AC-3e, 1.5 kW 220...230 V AC 50/60 Hz AC-4, 2.2 kW 380...415 V AC 50/60 Hz AC-4, 3 kW 440/690 V AC 50/60 Hz AC-4
    • Operating Time : 10...20 ms coil de-energisation and NO opening, 10...20 ms coil energisation and NO closing
    • Protective Treatment : TC IEC 60068, TC DIN 50016
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Tightening Torque : 0.8-1.3 N.m screw clamp terminals Philips No 2, 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm, 0.8-1.3 N.m screw clamp terminals pozidriv No 2
    • ICW Rated Short Time Withstand Current : 90 A 50 °C - 1 s for power circuit, 85 A 50 °C - 5 s for power circuit, 80 A 50 °C - 10 s for power circuit, 60 A 50 °C - 30 s for power circuit, 45 A 50 °C - 1 min for power circuit, 40 A 50 °C - 3 min for power circuit, 20 A 50 °C - >= 15 min for power circuit, 80 A - 1 s for signalling circuit, 90 A - 500 ms for signalling circuit, 110 A - 100 ms for signalling circuit
    • IE Rated Operational Current : 6 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 6 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
    • ITH Conventional Free Air Thermal Current : 20 A (at 60 °C) for power circuit, 10 A (at 50 °C) for signalling circuit
    • Carbon Footprint Of The Distribution Phase A4 : 0.0699882448144537, 0.1 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.2979052988386399, 0.3 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0 kg CO2 eq., 0.010778292366401048
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 1 kg CO2 eq., 0.9753347007368284
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 49 kg CO2 eq., 48.898115907556374
    • Connections Terminals : screw clamp terminals 1 1.5-4 mm²solid, screw clamp terminals 1 0.75-4 mm²flexible without cable end, screw clamp terminals 1 0.34-2.5 mm²flexible with cable end, screw clamp terminals 2 1.5-4 mm²solid, screw clamp terminals 2 0.75-4 mm²flexible without cable end, screw clamp terminals 2 0.34-1.5 mm²flexible with cable end
    • Add Ons : LA1KN22, LA1KN11, LA1KN40, LA1KN31, LA1KN20, LA1KN04, LA1KN02, LA1KN13
    • Auxiliaries : LA4KA1U, LA4KE1UG
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-02-26
    • HTML Description : TeSys K ContactorNumber of Poles: 3-PolesPole Contact Composition: 3 NOAuxilliary Contact Composition: 1 NORated Operational Current: 6AControl Circuit Voltage: 200-208V AC 50/60 HzNon-Reversing
    • Manufacturer : Schneider Electric
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1503003
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant
    • ROHS EUR Full Compliance Status : Compliant
    • ROHS EUR Full Compliance Status Id : COMPLIANT
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : N
    • WD Status : 5 - INITIALIZED WITH DataSCAN OK (Migration)
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Average Impedance : 3 mOhm - Ith 20 A 50 Hz for power circuit
    • Coil Technology : without built-in suppressor module
    • Compatibility Code : LC1K
    • Contactor Application : motor control
    • Device Short Name : LC1K
    • Heat Dissipation : 1.3-1.3 W
    • Hold In Power Consumption In VA : 4.5-4.5 VA (at 20 °C)
    • Inrush Power In VA : 30-30 VA (at 20 °C)
    • Non Overlap Distance : 0.5 mm
    • Package Weight Lbs : 179.0 g
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : contactor
    • Range : TeSys
    • Range Of Product : TeSys K
    • Returnability : No
    • Signalling Circuit Frequency : <= 400 Hz
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 50 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Relationship Type : Compatible relationship
    • Pep Code : ENVPEP1503003
    • Pep Verification Date : 2025-11-21
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed3-2023 06 06
    • Type Of Verification For The Pep : Independent internal review
    • Functional Unit Description : Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
    • Functional Unit Unit : unit
    • Product Kit Identifier : N
  • Environment Attributes Main
    • EU ROHS Directive : Compliant​, Compliant
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Reach Free SHVC : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : X
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 50.2521224443127
    • Circularity Profile : ENVEOLI1503003
    • Environmental Disclosure : ENVPEP1503003
    • IP Degree Of Protection : IP2X VDE 0106
    • Operating Altitude : 6561.68 ft (2000 m) without derating
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Free Of SVHC : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1503003
    • Pep Verification Date : 2025-11-21
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed3-2023 06 06
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : contactor
    • Range Of Product : TeSys K
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months