Schneider Electric at Mayer

Electronic time delay auxiliary contact block, TeSys K, 1C/O, on delay 1-30s, front, control 24...48V AC/DC

CONTACTOR TIMED CONTACTS

SQDLA2KT2E LA2KT2E 3389110230048
97.23 / EA
http://schema.org/OutOfStock
  • Depth: 38 mm
  • Warranty Length: 18 mth
TeSys K electronic time delay contact block, for contactors LC.K, LP.K, CA.K. It provides 1C/O contact rated up to 2A 240V AC, with an on-delay setting range 1-30s. To be used for contactors with 24-48V AC/DC coils (B7 to E7, BD to ED). Front mounting by clip-on, connections by attached wires to the contactor. It conforms to RoHS/REACh regulation.
QTY
  • Product Description
  • Specifications
TeSys K electronic time delay contact block, for contactors LC.K, LP.K, CA.K. It provides 1C/O contact rated up to 2A 240V AC, with an on-delay setting range 1-30s. To be used for contactors with 24-48V AC/DC coils (B7 to E7, BD to ED). Front mounting by clip-on, connections by attached wires to the contactor. It conforms to RoHS/REACh regulation.
  • Conformance Attributes
    • Product Certifications : CE, UKCA
    • Standards : EN/IEC 60947-5-1
  • Complementary Attributes
    • Ue Rated Operational Voltage : 24...48 V AC/DC control circuit, 240 V AC signalling circuit
    • Rated Operational Voltage Limits : 0.85...1.1 Uc
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SI
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Insulation Resistance : > 10 MOhm, > 10 MOhm
    • Range Of Product : TeSys K control relay, TeSys K
    • Reset Time : 1.5 s during time delay, 0.5 s after time delay
    • Carbon Footprint Of The Distribution Phase A4 : 0.0052306666666666665, 0 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.1 kg CO2 eq., 0.10090666666666666
    • Carbon Footprint Of The Installation Phase A5 : 0.0038499555555555555, 0 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 0.8 kg CO2 eq., 0.8185244444444444
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 3 kg CO2 eq., 3.1606
    • Rated Operational Voltage 39 : 24...48 V AC/DC control circuit, 240 V AC signalling circuit
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-24
    • Return Indicator : N
    • Stocking Flag : Y
    • Stock Policy : 2
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Use Carbon Footprint : 3.1606
    • Legacy Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 0901
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : No
    • China Rohs Label : 3
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Compatibility Code : LA1
    • Device Short Name : LA1
    • Energy Efficiency Optimized : False
    • Environmental Characteristic : normal environment
    • Mounting Location : front
    • Pole Contact Composition : 1 C/O
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Name : TeSys K
    • Product Or Component Type : time delay auxiliary contact block
    • Protective Treatment : TC IEC 60068
    • Range : TeSys
    • Returnability : No
    • Shielding Continuity Terminal : without
    • Software Version : v5.9.4
    • Sustainable Packaging : Yes
    • Time Delay Range : 1...30 s
    • Timer Type : on delay
    • Total Lifecycle Carbon Footprint : 4 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Connections Terminals : slip-on terminals
    • Ith Conventional Free Air Thermal Current : 2 A for signalling circuit
    • Warranty In Months : 18
    • Pep Code : ENVPEP2106022EN
    • Database Version : 2022-01
    • Pep Verification Date : 2025-06-17
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional Unit Description : To add instantaneous auxiliary contact blocks in front face on TeSys k contactors as NO and/or NC contacts for 20 years.
    • Functional Unit Quantity : 1
    • Functional Unit Unit : unit
    • Product Weight In G2 : 40
    • Reference Lifetime In Y2 : 20
    • Energy Model Manufacturing A1 A3 2 : Electricity Mix; Production mix; Low voltage; FR
    • Energy Model Installation A5 2 : Electricity Mix; Production mix; Low voltage; FR
    • Energy Model Use B6 2 : Electricity Mix; Production mix; Low voltage; FR
    • Energy Model End Of Life C1 C4 2 : Electricity Mix; Production mix; Low voltage; FR
    • Recyclability Potential In 2 : 43
    • Offer Owner Code : 190788
    • Height Nominal : 27 mm
    • Width Nominal : 38 mm
    • Climate Change Fossil Fuels Kg Co2 Eq Operational Energy Use B6 2 : 3.1524
    • Climate Change Total Kg Co2 Eq Operational Energy Use B6 2 : 3.1606
    • Depletion Of Abiotic Resources Fossil Fuels Mj Operational Energy Use B6 2 : 606.91
    • Ecotoxicity Fresh Water Ctue Operational Energy Use B6 2 : 22.321
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Operational Energy Use B6 2 : 81.925
    • Total Use Of Primary Energy During The Life Cycle Mj Operational Energy Use B6 2 : 663.02
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 2 : 56.111
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 2 : 12.512
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 2 : 606.91
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 2 : 56.111
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • Mercury Free : Yes
    • Carbon Footprint : 4.0891117333333336
    • Ambient Air Temperature For Operation : -10-60 °C
    • Environmental Disclosure : ENVPEP2106022EN
    • Eu Rohs Directive : Compliant By Exemption
    • Ip Degree Of Protection : IP20 conforming to IEC 60529
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2106022EN
    • Pep Verification Date : 2025-06-17
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Range Of Product : TeSys K control relay, TeSys K
    • Product Or Component Type : time delay auxiliary contact block
  • ETIM
    • ETIM 8 : EC002060
    • ETIM 9 : EC002060
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Country of Origin : Brazil, Germany, France, Tunisia
    • Depth : 38 mm