TeSys Deca reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 24 V AC coil

TeSys Deca reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 24 V AC coil

SQDLC2D65AB7 LC2D65AB7 3389119409612
1132.75 / EA
http://schema.org/OutOfStock
  • Depth: 120 mm
  • Warranty Length: 18 mth
TeSys Deca reversing contactor, 3 poles (3NO), for motor control applications up to 65A/590V AC-3 (30kW@400V). Rated 65A AC-3 30kW@400V, it includes a 24V 50/60Hz AC coil, 2NO+2NC aux contacts, a mechanical interlock. It provides 24V 50/60Hz AC coils, 2NO+2NC built-in auxiliary contacts (NC mirror contacts), power connection by EverLink BTR screw connectors, control by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (119mm width), DIN-rail mounting or screw fixing. With pre-wired reversing power connections, mechanical interlock (without electrical interlocking). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). Assembled with mechanical interlock and pre-wired reversing circuit. Clear separation between power and control circuits, easy front access to coil and auxiliary contacts connections. Equipped with a 24V AC coil that can be supplied at 50Hz or 60Hz. Provides 4 built-in auxiliary contacts 2NO + 2NC, NC contacts are mirror certified suitable to be included in the control of safety systems. High electrical durability, guaranteed for 1.6 million cycles at 65A AC-3 440V, for demanding motor switching applications. Robust design with high making and breaking capacities up to 20 In. Power connections by EverLink BTR screw terminals providing constant tightening pressure.
QTY
  • Features
  • Specifications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Assets
    • Cad : https://download.schneider-electric.com/files?p_Doc_Ref=LC2D40AB7_3D-CAD&p_File_name=LC2D40AB7_3D-simplified.stp, https://download.schneider-electric.com/files?p_Doc_Ref=LC2D40AB7_3D-CAD&p_File_name=LC2D40AB7_2D-back.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=LC2D40AB7_3D-CAD&p_File_name=LC2D40AB7_2D-back.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=LC2D40AB7_3D-CAD&p_File_name=LC2D40AB7_2D-bottom.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=LC2D40AB7_3D-CAD&p_File_name=LC2D40AB7_2D-bottom.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=LC2D40AB7_3D-CAD&p_File_name=LC2D40AB7_2D-front.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=LC2D40AB7_3D-CAD&p_File_name=LC2D40AB7_2D-front.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=LC2D40AB7_3D-CAD&p_File_name=LC2D40AB7_2D-isometric.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=LC2D40AB7_3D-CAD&p_File_name=LC2D40AB7_2D-isometric.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=LC2D40AB7_3D-CAD&p_File_name=LC2D40AB7_2D-left.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=LC2D40AB7_3D-CAD&p_File_name=LC2D40AB7_2D-left.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=LC2D40AB7_3D-CAD&p_File_name=LC2D40AB7_2D-right.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=LC2D40AB7_3D-CAD&p_File_name=LC2D40AB7_2D-right.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=LC2D40AB7_3D-CAD&p_File_name=LC2D40AB7_2D-top.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=LC2D40AB7_3D-CAD&p_File_name=LC2D40AB7_2D-top.dxf
  • Conformance Attributes
    • Product Certifications : UL, CSA, RINA, GOST, CCC, DNV, LROS (Lloyds register of shipping), GL, BV, UKCA
    • Standards : CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 60335-2-40:Annex JJ, IEC 60335-1
  • Complementary Attributes
    • Control Circuit Voltage Limits : 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz, 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz, 0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz, 1...1.1 Uc (60-70 °C):operational AC 50/60 Hz
    • Irms Rated Making Capacity : 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 1000 A at 440 V for power circuit conforming to IEC 60947
    • Maximum Horse Power Rating : 20 hp at 230/240 V AC 60 Hz for 3 phase motors, 40 hp at 460/480 V AC 60 Hz for 3 phase motors, 5 hp at 115 V AC 60 Hz for 1 phase motors, 10 hp at 230/240 V AC 60 Hz for 1 phase motors, 20 hp at 200/208 V AC 60 Hz for 3 phase motors, 50 hp at 575/600 V AC 60 Hz for 3 phase motors
    • Icw Rated Short Time Withstand Current : 520 A 40 °C - 10 s for power circuit, 900 A 40 °C - 1 s for power circuit, 110 A 40 °C - 10 min for power circuit, 260 A 40 °C - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
    • Ie Rated Operational Current : 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 65 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 65 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
    • Uc Control Circuit Voltage : 24 V, 24 V AC 50/60 Hz
    • Ue Rated Operational Voltage : power circuit <= 690 V AC 25...400 Hz, power circuit <= 300 V DC
    • Ui Rated Insulation Voltage : signalling circuit 600 V CSA, signalling circuit 600 V UL, power circuit 690 V IEC 60947-4-1, power circuit 600 V CSA, power circuit 600 V UL, signalling circuit 690 V IEC 60947-1
    • Control Circuit Type : AC 50/60 Hz
    • Maximum Motor Phase Current : 65 A
    • Maximum Operating Rate : 3600 cyc/h 60 °C
    • Minimum Switching Current : 5 mA for signalling circuit
    • Minimum Switching Voltage : 17 V for signalling circuit
    • Rated Breaking Capacity : 1000 A at 440 V for power circuit conforming to IEC 60947
    • Uimp Rated Impulse Withstand Voltage : 6 kV IEC 60947
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SI
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Associated Fuse Rating : 10 A gG for signalling circuit conforming to IEC 60947-5-1, 125 A gG at <= 690 V coordination type 1 for power circuit, 125 A gG at <= 690 V coordination type 2 for power circuit
    • Contactor Application : resistive load, motor control
    • Electrical Durability : 1.45 Mcycles 65 A AC-3 <= 440 V, 1.4 Mcycles 80 A AC-1 <= 440 V, 1.45 Mcycles 65 A AC-3e <= 440 V
    • Hold In Power Consumption In Va : 13-13 VA 60 Hz cos phi 0.3 (at 20 °C), 15-15 VA 50 Hz cos phi 0.3 (at 20 °C)
    • Inrush Power In Va : 140-140 VA 60 Hz cos phi 0.75 (at 20 °C), 160-160 VA 50 Hz cos phi 0.75 (at 20 °C)
    • Insulation Resistance : > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
    • Mechanical Robustness : vibrations contactor open2 Gn, 5...300 Hz, vibrations contactor closed4 Gn, 5...300 Hz, shocks contactor open10 Gn for 11 ms, shocks contactor closed15 Gn for 11 ms
    • Motor Power Kw : 18.5 kW at 220...230 V AC 50 Hz, 30 kW at 380...400 V AC 50 Hz, 37 kW at 415...440 V AC 50 Hz, 37 kW at 500 V AC 50 Hz, 37 kW at 660...690 V AC 50 Hz
    • Mounting Support : rail, plate
    • Non Overlap Time : 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
    • Operating Time : 4...19 ms opening, 12...26 ms closing
    • Power Dissipation Per Pole : 9.6 W AC-1, 6.3 W AC-3, 6.3 W AC-3e
    • Power Range : 15-25 kW 200-240 V 3 phase, 30-50 kW 380-440 V 3 phase, 30-50 kW 480-500 V 3 phase
    • Product Name : TeSys D, TeSys Deca
    • Range : TeSys, TeSys Deca
    • Range Of Product : TeSys D, TeSys Deca
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Tightening Torque : control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals Philips No 2, power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm, power circuit 5 N.m EverLink BTR screw connectors 1-25 mm² hexagonal 4 mm, control circuit 1.7 N.m screw clamp terminals pozidriv No 2, power circuit 2.5 N.m screw clamp terminals pozidriv No 2
    • Utilisation Category : AC-3, AC-1, AC-3e
    • Connections Terminals : control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end, control circuit screw clamp terminals 2 1-4 mm²solid, power circuit EverLink BTR screw connectors 2 1-25 mm²flexible without cable end, power circuit EverLink BTR screw connectors 1 1-35 mm²flexible with cable end, power circuit EverLink BTR screw connectors 2 1-25 mm²flexible with cable end, power circuit EverLink BTR screw connectors 1 1-35 mm²solid, power circuit EverLink BTR screw connectors 2 1-25 mm²solid, control circuit screw clamp terminals 1 1-4 mm²flexible without cable end, control circuit screw clamp terminals 2 1-4 mm²flexible without cable end, control circuit screw clamp terminals 1 1-4 mm²flexible with cable end, control circuit screw clamp terminals 1 1-4 mm²solid, power circuit EverLink BTR screw connectors 1 1-35 mm²flexible without cable end
    • Icw Rated Short Time Withstand Current : 520 A 40 °C - 10 s for power circuit, 900 A 40 °C - 1 s for power circuit, 110 A 40 °C - 10 min for power circuit, 260 A 40 °C - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
    • Ie Rated Operational Current : 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 65 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 65 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
    • Ith Conventional Free Air Thermal Current : 10 A (at 60 °C) for signalling circuit, 80 A (at 60 °C) for power circuit
    • Carbon Footprint Of The Distribution Phase A4 : 2.4027950407994467, 2 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 3.367160069901198, 3 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0.1 kg CO2 eq., 0.05060044605468097
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 11 kg CO2 eq., 11.18613720314669
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 153 kg CO2 eq., 153.24788341093736
    • Medium Desc : TeSys Deca reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 24 V AC coil
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-05-31
    • Global Commercial Status : Commercialised
    • Return Indicator : N
    • Stocking Flag : Y
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Legacy Weee Scope : In
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1503009EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant
    • Rohs Eur Full Compliance Status : Compliant
    • China Rohs In Scope : No
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Average Impedance : 1.5 mOhm - Ith 80 A 50 Hz for power circuit
    • Coil Technology : without built-in suppressor module
    • Compatibility Code : LC2D
    • Contact Compatibility : M2
    • Contactor Coil Voltage : 24 V AC standard
    • Device Short Name : LC2D
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Flame Retardance : V1 conforming to UL 94
    • Heat Dissipation : 4-5 W 50/60 Hz
    • Interlocking Type : mechanical
    • Mechanical Durability : 6 Mcycles
    • Motor Starter Type : reversing contactor
    • Overvoltage Category : III
    • Pole Contact Composition : 3 NO
    • Poles Description : 3P
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : reversing contactor
    • Protective Treatment : TH IEC 60068-2-30
    • Returnability : No
    • Signalling Circuit Frequency : 25...400 Hz
    • Software Version : v6.2.4
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 170 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Rated Thermal Current Ith : 80 A
    • Control Circuit Voltage : 24 V
    • Inf Motor Phase Current : 65 A
    • Pep Code : ENVPEP1503009EN
    • Database Version : 2024-01
    • Pep Verification Date : 2025-11-20
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3-2023 06 06
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional Unit Description : Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
    • Functional Unit Unit : unit
    • Energy Model Manufacturing A1 A3 2 : Electricity Mix; Low voltage; 2020; France, FR
    • Energy Model Installation A5 2 : No energy used
    • Energy Model Use B6 2 : Electricity Mix; Low voltage; 2020; France, FR
    • Energy Model End Of Life C1 C4 2 : Global, European and French datasets are used.
    • Height Nominal : 122 mm
    • Width Nominal : 119 mm
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Ambient Air Temperature For Operation : -40-60 °C, -40-60 °C, 60-70 °C with derating
    • Climatic Withstand : IACS E10, IEC 60947-1 Annex Q category D
    • Take Back : Nej
    • Recycled Metal Content At Cr Level : 0 %
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 170.25457617083936
    • Ambient Air Temperature For Storage : -60-80 °C
    • Circularity Profile : ENVEOLI1503009EN
    • Environmental Disclosure : ENVPEP1503009EN
    • Eu Rohs Directive : Compliant
    • Ip Degree Of Protection : IP20 front face IEC 60529
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1503009EN
    • Pep Verification Date : 2025-11-20
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3-2023 06 06
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Range Of Product : TeSys D, TeSys Deca
    • Product Or Component Type : reversing contactor
  • ETIM
    • ETIM 8 : EC000010
    • ETIM 9 : EC000010
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Depth : 120 mm
  • Overview Attributes
    • Device Presentation : preassembled with reversing power busbar