Schneider Electric at Mayer

TeSys Deca control relay - 3 NO + 2 NC - <= 690 V - 220 V AC standard coil

RELAY 600V 10AMP TESYS +OPTION

SQDCAD326M7 CAD326M7 3389110632064
79.43 / EA
http://schema.org/OutOfStock
  • Country of Origin: Indonesia
  • Depth: 84 mm
  • Warranty Length: 18 mth
TeSys Deca control relay, 5 contacts (3NO + 2NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13. It provides a 220V AC control circuit with no inrush consumption and equipped with a surge suppression device, connection by lugs. For high operating rates until 180 cycles/min and ambient temperature -40/+60°C, it procures high reliability and durability. Compact (45mm width), for clipping on 35mm DIN rail or fixing by screw. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine).
QTY
  • Product Description
  • Features
  • Specifications
TeSys Deca control relay, 5 contacts (3NO + 2NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13. It provides a 220V AC control circuit with no inrush consumption and equipped with a surge suppression device, connection by lugs. For high operating rates until 180 cycles/min and ambient temperature -40/+60°C, it procures high reliability and durability. Compact (45mm width), for clipping on 35mm DIN rail or fixing by screw. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine).
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Conformance Attributes
    • Product Certifications : CB, CCC, UL, CSA, EAC, CE, UKCA
    • Standards : EN/IEC 60947-5-1, GB/T 14048.5, UL 60947-5-1, CSA C22.2 No 60947-5-1, JIS C8201-5-1
  • Complementary Attributes
    • Control Circuit Voltage Limits : 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz, 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz, 0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz, 1...1.1 Uc (60-70 °C):operational AC 50/60 Hz
    • Irms Rated Making Capacity : 140 A AC IEC 60947-5-1, 250 A DC IEC 60947-5-1
    • Icw Rated Short Time Withstand Current : 100 A - 1 s, 120 A - 500 ms, 140 A - 100 ms
    • Ue Rated Operational Voltage : <= 690 V AC 25...400 Hz, <= 690 V AC 25...400 Hz, <= 690 V AC 25...400 Hz, <= 690 V AC 25...400 Hz, <= 690 V AC 25...400 Hz, <= 690 V AC 25...400 Hz
    • Ui Rated Insulation Voltage : 600 V UL, 600 V CSA, 690 V IEC 60947-5-1
    • Control Circuit Type : AC 50/60 Hz
    • Maximum Operating Rate : 180 cyc/mn
    • Minimum Switching Current : 5 mA
    • Minimum Switching Voltage : 17 V
    • Uc Control Circuit Voltage : 220 V AC 50/60 Hz
    • Uimp Rated Impulse Withstand Voltage : 6 kV IEC 60947
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SI
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Insulation Resistance : > 10 MOhm, > 10 MOhm
    • Mechanical Robustness : shocks control relay open10 Gn for 11 ms IEC 60068-2-27, shocks control relay closed15 Gn for 11 ms IEC 60068-2-27, vibrations control relay open2 Gn, 5...300 Hz IEC 60068-2-6, vibrations control relay closed4 Gn, 5...300 Hz IEC 60068-2-6
    • Mounting Support : plate, rail
    • Non Overlap Time : 1.5 ms on energisation between NC and NO contact, 1.5 ms on de-energisation between NC and NO contact
    • Operating Time : 12...22 ms coil energisation and NO closing, 4...12 ms coil de-energisation and NO opening, 4...19 ms coil energisation and NC opening, 6...17 ms coil de-energisation and NC closing
    • Range : TeSys, TeSys Deca
    • Utilisation Category : AC-14, AC-15, DC-13
    • Icw Rated Short Time Withstand Current : 100 A - 1 s, 120 A - 500 ms, 140 A - 100 ms
    • Carbon Footprint Of The Distribution Phase A4 : 0.2688271654154445, 0.3 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0.09473546449819852, 0.1 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 2 kg CO2 eq., 2.4052974453589133
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 15 kg CO2 eq., 15.364183683872902
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-30
    • Return Indicator : Y
    • Stocking Flag : Y
    • Stock Policy : 1
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Legacy Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1501004
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : No
    • China Rohs Label : 3
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Associated Fuse Rating : 10 A gG conforming to IEC 60947-5-1
    • Compatibility Code : CAD
    • Contactor Application : control circuit
    • Device Short Name : CAD
    • Hold In Power Consumption In Va : 8-8 VA 50 Hz (at 20 °C)
    • Inrush Power In Va : 70-70 VA 50 Hz (at 20 °C)
    • Mechanical Durability : 30 Mcycles
    • Pole Contact Composition : 3 NO + 2 NC
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Name : TeSys CAD
    • Product Or Component Type : control relay
    • Protective Treatment : TH IEC 60068
    • Range Of Product : TeSys D control relay
    • Returnability : Yes
    • Software Version : v6.2.4
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 18 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Connections Terminals : lugs-ring terminals 8 mm)
    • Ith Conventional Free Air Thermal Current : 10 A (at 60 °C)
    • Warranty In Months : 18
    • Pole Contact Comp : 3 NO + 2 NC
    • Control Circuit Voltage 21 : 220 V AC 50/60 Hz
    • Connections Terminals 55 Connections Terminals : lugs-ring terminals
    • Pep Code : ENVPEP1501004EN
    • Database Version : 2024-01
    • Pep Verification Date : 2026-03-17
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3-2023 06 06
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional Unit Description : Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
    • Functional Unit Quantity : 1
    • Functional Unit Unit : unit
    • Product Weight In G2 : 580
    • Reference Lifetime In Y2 : 20
    • Energy Consumption On Product Lifetime In Kwh : 170.82
    • Energy Model Manufacturing A1 A3 2 : Electricity Mix; Low voltage; 2020; France, FR
    • Energy Model Installation A5 2 : No energy used
    • Energy Model Use B6 2 : Electricity Mix; Low voltage; 2020; France, FR
    • Energy Model End Of Life C1 C4 2 : Global, European and French datasets are used.
    • Recyclability Potential In 2 : 66
    • Offer Owner Code : 190788
    • Height Nominal : 77 mm
    • Width Nominal : 45 mm
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    • Ambient Air Temperature For Operation : -40-60 °C, -40-60 °C, 60-70 °C with derating
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • Mercury Free : Yes
    • Carbon Footprint : 18.13304375914546
    • Ambient Air Temperature For Storage : -60-80 °C
    • Circularity Profile : ENVEOLI1501004
    • Environmental Disclosure : ENVPEP1501004EN
    • Eu Rohs Directive : Compliant By Exemption
    • Ip Degree Of Protection : IP2X front face VDE 0106
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1501004EN
    • Pep Verification Date : 2026-03-17
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3-2023 06 06
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : control relay
    • Range Of Product : TeSys D control relay
  • ETIM
    • ETIM 8 : EC000196
    • ETIM 9 : EC000196
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Country of Origin : Indonesia
    • Depth : 84 mm