Contactor coil, TeSys Deca, LX1D8, 380V AC 50/60Hz for 115 and 150A contactor

CONTACTOR COIL 380V AC IEC

SQDLX1D8Q7 LX1D8Q7 3389110868418
118.51 / EA
http://schema.org/OutOfStock
TeSys D replacement AC coil 380V 50/60Hz for TeSys D contactors. To be used with 3-pole and 4-pole contactors LC1 D115, LC1D150. It operates in the voltage limits 0.8-1.15 Uc and environments until 55°C. Coil with integral suppression device fitted as standard. Green Premium compliant (RoHS/REACh).
QTY
  • Product Description
  • Specifications
TeSys D replacement AC coil 380V 50/60Hz for TeSys D contactors. To be used with 3-pole and 4-pole contactors LC1 D115, LC1D150. It operates in the voltage limits 0.8-1.15 Uc and environments until 55°C. Coil with integral suppression device fitted as standard. Green Premium compliant (RoHS/REACh).
  • Environment
    • Ambient Air Temperature For Operation : -5-60 °C
  • Contractual warranty
    • Warranty : 18 months
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP110205EN
    • Sustainable Offer Status : Green Premium product
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
    • Reach Free Of Svhc : Yes
    • China Rohs Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Circularity Profile : N/A
    • Eu Rohs Directive : Pro-active compliance (Product out of EU RoHS legal scope)
  • Complementary
    • Control Circuit Voltage Limits : drop-out: 0.3...0.5 Uc at 50/60 Hz (at <55 °C) || operational: 0.8...1.15 Uc at 50/60 Hz (at <55 °C)
    • Inrush Power In Va : 280-350 VA 60 Hz cos phi 0.9 (at 20 °C) || 280-350 VA 50 Hz cos phi 0.9 (at 20 °C)
    • Coil Technology : without built-in suppressor module
    • Hold-In Power Consumption In Va : 2-18 VA 60 Hz cos phi 0.9 (at 20 °C) || 2-18 VA 50 Hz cos phi 0.9 (at 20 °C)
    • Heat Dissipation : 3-4.5 W 50/60 Hz
  • Specifications
    • Country of Origin : United States
    • Average Resistance : 21011 Ohm 20 °C
    • [Uc] Control Circuit Voltage : 380 V AC 50/60 Hz
    • Control Circuit Type : AC 50/60 Hz
    • Product Or Component Type : contactor coil
    • Range : TeSys
    • Inductance Of Closed Circuit : 482.42 H
    • Maximum Operating Rate : 1200 cyc/h 60 °C
    • Mechanical Durability : 8 Mcycles
    • Product Compatibility : LC1D115 || LC1D150
    • Device Short Name : LX1D8