Schneider Electric at Mayer

IEC contactor, TeSys Deca, nonreversing, 40A resistive, 4 pole, 4 NO, 48VAC 50/60Hz coil, open style

CONTACTOR 600VAC 40AMP IEC + O

SQDLC1DT40E7 LC1DT40E7 3389110244656
270.80 / EA
http://schema.org/OutOfStock
  • Country of Origin: Indonesia
  • Depth: 3.9 in
  • Height: 3.58 in
  • Warranty Length: 18 mth
  • Width: 1.77 in
TeSys Deca contactor, 4 poles (4NO), for non-inductive load applications up to 40A/440V AC-1. They can be used to create motor starters for almost any type of application. It provides a 48V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror
QTY
  • Product Description
  • Features
  • Specifications
TeSys Deca contactor, 4 poles (4NO), for non-inductive load applications up to 40A/440V AC-1. They can be used to create motor starters for almost any type of application. It provides a 48V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror
  • Uc Control Circuit Voltage
    • 48 V AC 50/60 Hz
  • Insulation Resistance
    • > 10 MOhm for signalling circuit
  • Heat Dissipation
    • 2-3 W at 50/60 Hz
  • Connections Terminals
    • control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end
    • control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffne
  • Mounting Support
    • plate
    • rail
  • Uimp Rated Impulse Withstand Voltage
    • 6 kV IEC 60947
  • Climatic Withstand
    • IACS E10 exposure to damp heat
    • IEC 60947-1 Annex Q category D exposure to damp heat
  • Power Dissipation Per Pole
    • 3.2 W AC-1
  • Maximum Operating Rate
    • 3600 cyc/h at 60 °C
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Non Overlap Time
    • 1.5 ms on de-energisation between NC and NO contact
    • 1.5 ms on energisation between NC and NO contact
  • Carbon Footprint Of The End Of Life Phase C1 To C4
    • 1.0322065053715634
    • 1 kg CO2 eq.
  • Standards
    • CSA C22.2 No 14
    • EN 60947-4-1
    • EN 60947-5-1
    • IEC 60947-4-1
    • IEC 60947-5-1
    • UL 60947-4-1
    • IEC 60335-1
  • Ue Rated Operational Voltage
    • power circuit <= 690 V AC 25...400 Hz
    • power circuit <= 300 V DC
  • Ui Rated Insulation Voltage
    • power circuit 600 V CSA
    • power circuit 600 V UL
    • signalling circuit 690 V IEC 60947-1
    • si
  • Operating Time
    • 4...19 ms opening
    • 12...22 ms closing
  • Control Circuit Type
    • AC 50/60 Hz
  • Ip Degree Of Protection
    • IP20 front face IEC 60529
  • Minimum Switching Voltage
    • 17 V for signalling circuit
  • Carbon Footprint Of The Manufacturing Phase A1 To A3
    • 3 kg CO2 eq.
    • 2.6125401418078362
  • Protective Treatment
    • THIEC 60068-2-30
  • Average Impedance
    • 2 mOhm - Ith 40 A 50 Hz for power circuit
  • Electrical Durability
    • 1.4 Mcycles 40 A AC-1 <= 440 V
  • Market Segmentation
    • Commercial
    • Industrial
  • Persona Type Names
    • End User
    • Contractor
    • Original Equipment Manufacturer
    • OEM - Control Panelbuilder
    • Panel Builder
    • System Integrator
  • Fire Resistance
    • 850 °C IEC 60695-2-1
  • Flame Retardance
    • V1 conforming to UL 94
  • Carbon Footprint Of The Use Phase B2 B3 B4 B6
    • 205 kg CO2 eq.
    • 204.6547108272759
  • Persona Type Ids
    • EU
    • LC
    • OM
    • OM8
    • PB
    • SI
  • Safety Reliability Level
    • B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
    • B10d = 1369863 cycles contactor with nominal load EN/ISO 13
  • Carbon Footprint Of The Distribution Phase A4
    • 0.1972420425676922
    • 0.2 kg CO2 eq.
  • Tightening Torque
    • control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm
    • control circuit 1.7 N.
  • Ith Conventional Free Air Thermal Current
    • 10 A (at 60 °C) for signalling circuit
    • 40 A (at 60 °C) for power circuit
  • Irms Rated Making Capacity
    • 140 A AC for signalling circuit conforming to IEC 60947-5-1
    • 250 A DC for s
  • Mechanical Robustness
    • vibrations contactor open 2 Gn, 5...300 Hz)
    • vibrations contactor closed 4 Gn, 5...300 Hz)
    • vibrations contactor closed 4
  • Minimum Switching Current
    • 5 mA for signalling circuit
  • Control Circuit Voltage Limits
    • 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz
    • 0.8...1.1 Uc (-40-60 °C)
  • Ie Rated Operational Current
    • 40 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
    • 40 A (at <60 °C) at <= 440 V AC AC
  • Icw Rated Short Time Withstand Current
    • 50 A 40 °C - 10 min for power circuit
    • 120 A 40 °C - 1 min for power circuit
    • 120 A 40 °C - 1 min for po
  • Hold In Power Consumption In Va
    • 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20 °C)
    • 7-7 VA 50 Hz cos phi 0.3 (at 20 °C)
    • 7-7 VA 50 Hz cos phi 0
  • Market Segmentation Id
    • COMMERCIAL
    • INDUSTRIAL
  • Inrush Power In Va
    • 70-70 VA 60 Hz cos phi 0.75 (at 20 °C)
    • 70-70 VA 50 Hz cos phi 0.75 (at 20 °C)
    • 70-70 VA 50 Hz cos p
  • Associated Fuse Rating
    • 10 A gG for signalling circuit conforming to IEC 60947-5-1
    • 63 A gG at <= 690
  • Permissible Ambient Air Temperature Around The Device
    • -40-60 °C
    • 60-70 °C with derating
  • Rated Breaking Capacity
    • 450 A at 440 V for power circuit conforming to IEC 60947
  • Range
    • TeSys
    • TeSys Deca
  • Product Certifications
    • DNV
    • GL
    • CCC
    • LROS (Lloyds register of shipping)
    • RINA
    • BV
    • GOST
    • UL
    • CSA
    • CB
  • Important Information Attributes
    • Country Id : US
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-09
    • ETIM 10 : EC000066
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Manufacturing Carbon Footprint : 2.61254014180784
    • Distribution Carbon Footprint : 0.197242042567692
    • Use Carbon Footprint : 204.654710827276
    • End Of Life Carbon Footprint : 1.03220650537156
    • Legacy WEEE Scope : In
    • WEEE Product Category : 5
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI110229EN
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • ROHS Eur In Scope : Yes
    • ROHS Eur Status : Compliant
    • ROHS Eur Conformity Date : 627
    • ROHS Eur Full Compliance Status : Compliant
    • ROHS Eur Full Compliance Status Id : COMPLIANT
    • China ROHS In Scope : No
    • China ROHS Label : 1
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : N
    • WD Status : 1 - GSC certified
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Coil Technology : without built-in suppressor module
    • Compatibility Code : LC1D
    • Contact Compatibility : M6
    • Contactor Application : resistive load
    • Device Short Name : LC1D
    • Mechanical Durability : 15 Mcycles
    • Overvoltage Category : III
    • Package Weight Lbs : 475.000 g
    • Pole Contact Composition : 4 NO
    • Poles Description : 4P
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : contactor
    • Range Of Product : TeSys Deca
    • Returnability : No
    • Signalling Circuit Frequency : 25...400 Hz
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 208 kg CO2 eq.
    • Utilisation Category : AC-1
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Carbon Footprint Kg Co2 Eq Total Life Cycle : 208.496699517023
  • General Attributes
    • Product Or Component Type : contactor
    • Range Of Product : TeSys Deca
  • Environment Attributes
    • ROHS Exemption Information : Yes
    • China ROHS Url : https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=exportPdfRoHSChina&pid=620804&lang=en-us
    • Take Back : No
    • Reach Free Shvc : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Carbon Footprint : 208.496699517023
    • Circularity Profile : ENVEOLI110229EN
    • Environmental Disclosure : ENVPEP110230EN
    • Eu Rohs Directive : Compliant
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Free Of Svhc : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Country of Origin : Indonesia
    • Height : 3.58 in
    • Width : 1.77 in
    • Depth : 3.9 in