IEC contactor, TeSys D, nonreversing, 40A resistive, 4 pole, 4 NO, 24VDC coil, open style

CONTACTOR 600VAC 40AMP AC1 IEC

SQDLC1DT406BD LC1DT406BD 785901486695
268.75 / EA
  • Certifications: BV, CCC, CSA, DNV, GL, GOST, LROS (Lloyds Register Of Shipping), RINA, UL
  • Contact Configuration: 1 NO + 1 NC, 4 NO
  • Depth: 107 mm
  • Height: 91 mm
  • Impedance: 2 MOhm - Ith 40 A 50 Hz Power Circuit
  • Net Weight: 0.425 kg
  • Standard: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, UL 508
  • Storage Temperature: -60-80 °C
  • Warranty Length: 18 mth
  • Width: 45 mm
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 40A resistive load rating. Contactor is supplied with a 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.58 inches tall, 1.77 inches wide and 4.21 inches deep. It weighs 0.94 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
  • Product Description
  • Specifications
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 40A resistive load rating. Contactor is supplied with a 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.58 inches tall, 1.77 inches wide and 4.21 inches deep. It weighs 0.94 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
  • Complementary
    • Inrush Power In W : 5.4-5.4 W 20 °C)
    • Control Circuit Voltage Limits : 0.1...0.25 Uc -40-70 °C drop-out DC || 0.7...1.25 Uc -40-60 °C operational DC || 1...1.25 Uc 60-70 °C operational DC
    • Signalling Circuit Frequency : 25...400 Hz
    • Coil Technology : built-in bidirectional peak limiting diode suppressor
    • Hold-In Power Consumption In W : 5.4-5.4 W 20 °C
    • Insulation Resistance : > 10 MOhm signalling circuit
    • Time Constant : 28 ms
    • Non-Overlap Time : 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
    • Minimum Switching Voltage : 17 V signalling circuit
    • Minimum Switching Current : 5 mA signalling circuit
    • Auxiliary Contacts Type : mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
  • Environment
    • Net Weight : 0.425 kg
    • Pollution Degree : 3
    • Ambient Air Temperature For Storage : -60-80 °C
    • Height : 91 mm
    • Depth : 107 mm
    • Ip Degree Of Protection : IP20 front face IEC 60529
    • Protective Treatment : TH IEC 60068-2-30
    • Width : 45 mm
    • Flame Retardance : V1 conforming to UL 94
    • Mechanical Robustness : vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor closed15 Gn for 11 ms || shocks contactor open8 Gn for 11 ms
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Ambient Air Temperature For Operation : -40-60 °C || 60-70 °C with derating
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
  • Offer Sustainability
    • Pvc Free : Yes
    • China Rohs Regulation : Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Sustainable Offer Status : Green Premium product
    • Eu Rohs Directive : Compliant
    • Environmental Disclosure : ENVPEP110229EN
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Mercury Free : Yes
    • Reach Free Of Svhc : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Rohs Exemption Information : Yes
    • Toxic Heavy Metal Free : Yes
    • Circularity Profile : ENVEOLI1102029EN
  • Contractual warranty
    • Warranty : 18 months
  • Device Short Name : LC1D
  • Pole Contact Composition : 4 NO
  • Product Or Component Type : contactor
  • Average Impedance : 2 mOhm - Ith 40 A 50 Hz power circuit
  • Rated Breaking Capacity : 450 A 440 V power circuit IEC 60947
  • Mounting Support : rail || plate
  • [Uimp] Rated Impulse Withstand Voltage : 6 kV IEC 60947
  • Operating Time : 16...24 ms opening || 53.55...72.45 ms closing
  • Mechanical Durability : 30 Mcycles
  • [Uc] Control Circuit Voltage : 24 V DC
  • Irms Rated Making Capacity : 140 A AC signalling circuit IEC 60947-5-1 || 250 A DC signalling circuit IEC 60947-5-1 || 450 A 440 V power circuit IEC 60947
  • Standards : CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
  • Associated Fuse Rating : 10 A gG signalling circuit IEC 60947-5-1 || 63 A gG <= 690 V type 1 power circuit || 40 A gG <= 690 V type 2 power circuit
  • Overvoltage Category : III
  • [Ie] Rated Operational Current : 40 A 60 °C) <= 440 V AC AC-1 power circuit
  • Product Name : TeSys D || TeSys Deca
  • Protective Cover : with
  • Contactor Application : resistive load
  • [Ue] Rated Operational Voltage : power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
  • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • [Ith] Conventional Free Air Thermal Current : 10 A 60 °C signalling circuit || 40 A 60 °C power circuit
  • Maximum Operating Rate : 3600 cyc/h 60 °C
  • Poles Description : 4P
  • Tightening Torque : control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5 || control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5 || power circuit 1.8 N.m lugs-ring terminals flat Ø 6 mm M3.5 || power circuit 1.8 N.m lugs-ring terminals Philips No 2 M3.5 || control circuit 1.7 N.m screw clamp terminals pozidriv No 2 || power circuit 2.5 N.m screw clamp terminals pozidriv No 2
  • Power Dissipation Per Pole : 3.2 W AC-1
  • Product Certifications : UL || LROS (Lloyds register of shipping) || BV || CSA || GL || RINA || CCC || GOST || DNV
  • Auxiliary Contact Composition : 1 NO + 1 NC
  • Control Circuit Type : DC standard
  • Utilisation Category : AC-1
  • Electrical Durability : 1.4 Mcycles 40 A AC-1 <= 440 V
  • Range : TeSys || TeSys Deca
  • [Icw] Rated Short-Time Withstand Current : 50 A 40 °C - 10 min power circuit || 120 A 40 °C - 1 min power circuit || 240 A 40 °C - 10 s power circuit || 380 A 40 °C - 1 s power circuit || 100 A - 1 s signalling circuit || 120 A - 500 ms signalling circuit || 140 A - 100 ms signalling circuit
  • [Ui] Rated Insulation Voltage : power circuit 600 V CSA || power circuit 600 V UL || signalling circuit 690 V IEC 60947-1 || signalling circuit 600 V CSA || signalling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
  • Connections - Terminals : control circuit lugs-ring terminals 8 mm) || power circuit lugs-ring terminals 8 mm)