Schneider Electric at Mayer

IEC contactor, TeSys D, nonreversing, 125A resistive, 4 pole, 2 NO and 2 NC, 120VAC 60Hz coil, open style

CONTACTOR 575VAC 80AMP IEC +OP

SQDLC1D80008G6 LC1D80008G6 785901225539
566.62 / EACH
  • Certifications: BV, CCC, CSA, DNV, GL, GOST, LROS (Lloyds Register Of Shipping), RINA, UKCA, UL
  • Contact Configuration: 2 NO + 2 NC
  • Depth: 140 mm
  • Height: 127 mm
  • Impedance: 0.8 MOhm - Ith 125 A 50 Hz Power Circuit
  • Net Weight: 1.84 kg
  • Standard: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508
  • Storage Temperature: -60-80 °C
  • Warranty Length: 18 mth
  • Width: 96 mm
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has two normally open and two normally closed power contacts. Power contacts have a 110A resistive load rating. Contactor is supplied with a 120 VAC 60 Hz coil. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.78 inches wide and 5.51 inches deep. It weighs 4.06 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
  • Product Description
  • Specifications
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has two normally open and two normally closed power contacts. Power contacts have a 110A resistive load rating. Contactor is supplied with a 120 VAC 60 Hz coil. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.78 inches wide and 5.51 inches deep. It weighs 4.06 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
  • [Uimp] Rated Impulse Withstand Voltage : 8 kV IEC 60947
  • [Uc] Control Circuit Voltage : 120 V AC 60 Hz
  • Product Certifications : BV || CSA || GOST || LROS (Lloyds register of shipping) || GL || RINA || UL || DNV || CCC || UKCA
  • Mounting Support : plate || rail
  • Standards : CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508
  • Irms Rated Making Capacity : 1100 A 440 V power circuit IEC 60947
  • [Ui] Rated Insulation Voltage : power circuit 600 V CSA || power circuit 600 V UL || power circuit 1000 V IEC 60947-4-1
  • Rated Breaking Capacity : 1100 A 440 V power circuit IEC 60947
  • Pole Contact Composition : 2 NO + 2 NC
  • Control Circuit Type : AC 60 Hz
  • Tightening Torque : control circuit 1.2 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.2 N.m screw clamp terminals Philips No 2 || power circuit 12 N.m connector flat Ø 6 to Ø 8 mm || power circuit 12 N.m connector hexagonal 4 mm
  • Operating Time : 20...35 ms closing || 6...20 ms opening
  • Device Short Name : LC1D
  • Power Dissipation Per Pole : 12.5 W AC-1
  • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • Connections - Terminals : control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1 1-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²solid without cable end || control circuit screw clamp terminals 2 1-4 mm²solid without cable end || power circuit connector 1 4-50 mm²flexible without cable end || power circuit connector 2 4-25 mm²flexible without cable end || power circuit connector 1 4-50 mm²flexible with cable end || power circuit connector 2 4-16 mm²flexible with cable end || power circuit connector 1 4-50 mm²solid without cable end || power circuit connector 2 4-25 mm²solid without cable end
  • Average Impedance : 0.8 mOhm - Ith 125 A 50 Hz power circuit
  • Maximum Operating Rate : 3600 cyc/h 60 °C
  • Range : TeSys
  • Product Or Component Type : contactor
  • Mechanical Durability : 10 Mcycles
  • Protective Cover : without
  • Contactor Application : resistive load
  • [Ue] Rated Operational Voltage : power circuit <= 300 V DC 25...400 Hz || power circuit <= 690 V AC
  • Overvoltage Category : III
  • Utilisation Category : AC-1
  • Associated Fuse Rating : 200 A gG <= 690 V type 1 power circuit || 160 A gG <= 690 V type 2 power circuit
  • Product Name : TeSys D
  • [Ith] Conventional Free Air Thermal Current : 125 A 60 °C power circuit
  • [Ie] Rated Operational Current : 125 A 60 °C) <= 440 V AC AC-1 power circuit
  • Electrical Durability : 0.8 Mcycles 125 A AC-1 <= 440 V
  • Poles Description : 4P
  • [Icw] Rated Short-Time Withstand Current : 640 A 40 °C - 10 s power circuit || 990 A 40 °C - 1 s power circuit || 135 A 40 °C - 10 min power circuit || 320 A 40 °C - 1 min power circuit
  • Environment
    • Ambient Air Temperature For Operation : -40-60 °C || 60-70 °C with derating
    • Width : 96 mm
    • Protective Treatment : TH IEC 60068-2-30
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Ip Degree Of Protection : IP20 front face IEC 60529
    • Depth : 140 mm
    • Mechanical Robustness : vibrations contactor open2 Gn, 5...300 Hz || shocks contactor open8 Gn for 11 ms || vibrations contactor closed3 Gn, 5...300 Hz || shocks contactor closed10 Gn for 11 ms
    • Flame Retardance : V1 conforming to UL 94
    • Ambient Air Temperature For Storage : -60-80 °C
    • Pollution Degree : 3
    • Height : 127 mm
    • Net Weight : 1.84 kg
  • Offer Sustainability
    • Sustainable Offer Status : Green Premium product
    • Toxic Heavy Metal Free : Yes
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • China Rohs Regulation : Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pvc Free : Yes
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
    • Environmental Disclosure : ENVPEP110205EN
    • Eu Rohs Directive : Compliant
    • Rohs Exemption Information : Yes
    • Reach Free Of Svhc : Yes
    • Mercury Free : Yes
  • Contractual warranty
    • Warranty : 18 months
  • Complementary
    • Heat Dissipation : 6-10 W 60 Hz
    • Inrush Power In Va : 220-220 VA 60 Hz 0.75 20 °C)
    • Coil Technology : without built-in suppressor module
    • Hold-In Power Consumption In Va : 22-22 VA 60 Hz 0.3 20 °C)
    • Control Circuit Voltage Limits : 0.85...1.1 Uc -40-55 °C operational AC 60 Hz || 0.3...0.6 Uc -40-70 °C drop-out AC 60 Hz || 1...1.1 Uc 55-70 °C operational AC 60 Hz