IEC contactor, TeSys D, nonreversing, 95A, 60HP at 480VAC, 3 phase, 3 pole, 3 NO, 440VAC 50/60Hz coil, open style

IEC contactor, TeSys D, nonreversing, 95A, 60HP at 480VAC, 3 phase, 3 pole, 3 NO, 440VAC 50/60Hz coil, open style

SQDLC1D95R7 LC1D95R7 338911045189
0.00 / EA
  • Certifications: BV, CCC, CSA, DNV-GL, EAC, IECEE CB Scheme, LROS (Lloyds Register Of Shipping), RINA, UKCA, UL
  • Contact Configuration: 1 NO + 1 NC
  • Contact Configuration: 3 NO
  • Depth: 130 mm
  • Height: 127 mm
  • Impedance: 0.8 MOhm - Ith 125 A 50 Hz Power Circuit
  • Net Weight: 1.61 kg
  • Standard: CSA C22.2 No 60947-4-1, CSA C22.2 No 60947-5-1, EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, GB/T 14048.4, UL 60947-4-1, UL 60947-5-1
  • Storage Temperature: -60-80 °C
  • Warranty Length: 18 mth
  • Width: 85 mm
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 95A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. Contactor is supplied with a 440 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 5.12 inches deep. It weighs 3.55 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
  • Product Description
  • Specifications
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 95A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. Contactor is supplied with a 440 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 5.12 inches deep. It weighs 3.55 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
  • Complementary
    • Insulation Resistance : > 10 MOhm signalling circuit
    • Auxiliary Contacts Type : mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
    • Inrush Power In Va : 245-245 VA 60 Hz 0.75 20 °C) || 245-245 VA 50 Hz 0.75 20 °C)
    • Hold-In Power Consumption In Va : 26-26 VA 60 Hz 0.3 20 °C) || 26-26 VA 50 Hz 0.3 20 °C)
    • Signalling Circuit Frequency : 25...400 Hz
    • Heat Dissipation : 6-10 W 50/60 Hz
    • Minimum Switching Voltage : 17 V signalling circuit
    • Non-Overlap Time : 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
    • Control Circuit Voltage Limits : 0.8...1.1 Uc -40-55 °C operational AC 50 Hz || 0.85...1.1 Uc -40-55 °C operational AC 60 Hz || 0.3...0.6 Uc -40-70 °C drop-out AC 50/60 Hz || 1...1.1 Uc 55-70 °C operational AC 50/60 Hz
    • Minimum Switching Current : 5 mA signalling circuit
    • Coil Technology : without built-in suppressor module
  • Contractual warranty
    • Warranty : 18 months
  • Environment
    • Net Weight : 1.61 kg
    • Width : 85 mm
    • Ambient Air Temperature For Storage : -60-80 °C
    • Depth : 130 mm
    • Ambient Air Temperature For Operation : -40-60 °C || 60-70 °C with derating
    • Mechanical Robustness : vibrations contactor open2 Gn, 5...300 Hz || shocks contactor open8 Gn for 11 ms || vibrations contactor closed3 Gn, 5...300 Hz || shocks contactor closed10 Gn for 11 ms
    • Ip Degree Of Protection : IP20 front face IEC 60529
    • Pollution Degree : 3
    • Protective Treatment : TH IEC 60068-2-30
    • Flame Retardance : V1 conforming to UL 94
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Height : 127 mm
  • Connections - Terminals : control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1 1-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²solid without cable end || control circuit screw clamp terminals 2 1-4 mm²solid without cable end || power circuit connector 1 4-50 mm²flexible without cable end || power circuit connector 2 4-25 mm²flexible without cable end || power circuit connector 1 4-50 mm²flexible with cable end || power circuit connector 2 4-16 mm²flexible with cable end || power circuit connector 1 4-50 mm²solid without cable end || power circuit connector 2 4-25 mm²solid without cable end
  • Contactor Application : resistive load || motor control
  • Auxiliary Contact Composition : 1 NO + 1 NC
  • Control Circuit Type : AC 50/60 Hz
  • Operating Time : 20...35 ms closing || 6...20 ms opening
  • Device Short Name : LC1D
  • Range : TeSys
  • Product Certifications : IECEE CB Scheme || UL || CSA || CCC || EAC || LROS (Lloyds register of shipping) || RINA || BV || DNV-GL || UKCA
  • Overvoltage Category : III
  • Protective Cover : with
  • [Ie] Rated Operational Current : 95 A 60 °C) <= 440 V AC-3 power circuit || 125 A 60 °C) <= 690 V AC-1 power circuit
  • [Uimp] Rated Impulse Withstand Voltage : 8 kV IEC 60947
  • Maximum Operating Rate : 3600 cyc/h 60 °C
  • Pole Contact Composition : 3 NO
  • Motor Power Kw : 25 kW 220...230 V AC 50 Hz AC-3) || 45 kW 380...400 V AC 50 Hz AC-3) || 45 kW 415...440 V AC 50 Hz AC-3) || 55 kW 500 V AC 50 Hz AC-3) || 45 kW 660...690 V AC 50 Hz AC-3) || 45 kW 1000 V AC 50 Hz AC-3)
  • Safety Reliability Level : B10d = 1.3 Mcycles contactor with nominal load EN/ISO 13849-1 || B10d = 20 Mcycles contactor with mechanical load EN/ISO 13849-1
  • Utilisation Category : AC-3 || AC-1 || AC-4
  • Power Dissipation Per Pole : 12.5 W AC-1 || 7.2 W AC-3
  • Irms Rated Making Capacity : 1100 A 440 V AC power circuit IEC 60947 || 140 A AC signalling circuit IEC 60947-5-1 || 250 A DC signalling circuit IEC 60947-5-1
  • Rated Breaking Capacity : 1100 A 440 V power circuit IEC 60947
  • Average Impedance : 0.8 mOhm - Ith 125 A 50 Hz power circuit
  • [Ith] Conventional Free Air Thermal Current : 10 A 60 °C signalling circuit || 125 A 60 °C power circuit
  • Product Or Component Type : contactor
  • Maximum Horse Power Rating : 7.5 hp 115 V at AC 60 Hz for 1 phase || 15 hp 230/240 V at AC 60 Hz for 1 phase || 25 hp 200/208 V at AC 60 Hz for 3 phase || 30 hp 230/240 V at AC 60 Hz for 3 phase || 60 hp 460/480 V at AC 60 Hz for 3 phase || 60 hp 575/600 V at AC 60 Hz for 3 phase
  • Mounting Support : plate || rail
  • [Icw] Rated Short-Time Withstand Current : 1100 A 40 °C - 1 s power circuit || 800 A 40 °C - 10 s power circuit || 400 A 40 °C - 1 min power circuit || 135 A 40 °C - 10 min power circuit || 140 A - 100 ms signalling circuit || 120 A - 500 ms signalling circuit || 100 A - 1 s signalling circuit
  • Electrical Durability : 1.2 Mcycles 95 A AC-3 || 1.3 Mcycles 125 A AC-1
  • Standards : EN/IEC 60947-1 || EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || CSA C22.2 No 60947-4-1 || CSA C22.2 No 60947-5-1 || GB/T 14048.4
  • Mechanical Durability : 4 Mcycles
  • [Ui] Rated Insulation Voltage : power circuit 1000 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || signalling circuit 690 V IEC 60947-1 || signalling circuit 600 V CSA || signalling circuit 600 V UL
  • Associated Fuse Rating : 10 A gG signalling circuit IEC 60947-5-1 || 200 A gG <= 690 V type 1 power circuit || 160 A gG <= 690 V type 2 power circuit
  • Tightening Torque : control circuit 1.2 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.2 N.m screw clamp terminals Philips No 2 || power circuit 12 N.m connector flat Ø 6 to Ø 8 mm || power circuit 12 N.m connector hexagonal 4 mm
  • [Uc] Control Circuit Voltage : 440 V AC 50/60 Hz
  • Product Name : TeSys D
  • [Ue] Rated Operational Voltage : power circuit 1000 V AC 25...400 Hz
  • Poles Description : 3P
  • Offer Sustainability
    • Environmental Disclosure : ENVPEP110205EN
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Sustainable Offer Status : Green Premium product
    • Mercury Free : Yes
    • Pvc Free : Yes
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • China Rohs Regulation : Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Reach Free Of Svhc : Yes
    • Eu Rohs Directive : Compliant
    • Toxic Heavy Metal Free : Yes
    • Rohs Exemption Information : Yes