IEC contactor, TeSys Deca, nonreversing, 95A, 60HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VDC coil, open style

IEC contactor, TeSys Deca, nonreversing, 95A, 60HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VDC coil, open style

SQDLC1D95BD LC1D95BD 3389110450576
774.05 / EA
http://schema.org/OutOfStock
  • Country of Origin: USA
  • Depth: 186 mm
  • Warranty Length: 18 mth
TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 95A/690V AC-3/AC-3e (45kW@400V). It provides a 24V DC coil, 1NO+1NC built-in auxiliary contacts, power connections by screw terminals and control by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (85mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, CCC, EAC, Marine), Sustainability compliant. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Multi standards certified (IEC, CCC, EAC, Marine). Contactor is supplied with a 24 VDC coil
QTY
  • Product Description
  • Features
  • Specifications
TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 95A/690V AC-3/AC-3e (45kW@400V). It provides a 24V DC coil, 1NO+1NC built-in auxiliary contacts, power connections by screw terminals and control by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (85mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, CCC, EAC, Marine), Sustainability compliant. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Multi standards certified (IEC, CCC, EAC, Marine). Contactor is supplied with a 24 VDC coil
  • Features
    • Long durability with high operating rate
    • Reliable performance under high environment
    • Multi sdandards certified makes it possible to wide application
    • Easy installation and maintenance with compact design
    • Multiple and flexible mounting methods depending on exact need
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Conformance Attributes
    • Product Certifications : IECEE CB Scheme, CCC, EAC, LROS (Lloyds register of shipping), RINA, BV, DNV-GL
    • Standards : EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, IEC 60335-2-40:Annex JJ, UL 60335-2-40:Annex JJ, IEC 60335-1:Clause 30.2
  • Complementary Attributes
    • Control Circuit Voltage Limits : 0.1...0.3 Uc (-40-70 °C):drop-out DC, 0.85...1.1 Uc (-40-55 °C):operational DC, 1...1.1 Uc (55-70 °C):operational DC
    • IRMS Rated Making Capacity : 1100 A at 440 V AC for power circuit conforming to IEC 60947, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1
    • Maximum Horse Power Rating : 30 hp at 230/240 V AC 60 Hz for 3 phase motors, 7.5 hp at 120 V AC 60 Hz for 1 phase motors, 15 hp at 230/240 V AC 60 Hz for 1 phase motors, 30 hp at 200/208 V AC 60 Hz for 3 phase motors, 60 hp at 460/480 V AC 60 Hz for 3 phase motors, 60 hp at 575/600 V AC 60 Hz for 3 phase motors
    • Control Circuit Type : DC standard
    • Maximum Motor Phase Current : 95 A
    • Maximum Operating Rate : 3600 cyc/h at 60 °C
    • Minimum Switching Current : 5 mA for signalling circuit
    • Minimum Switching Voltage : 17 V for signalling circuit
    • Rated Breaking Capacity : 1100 A at 440 V for power circuit conforming to IEC 60947
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SI
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Associated Fuse Rating : 10 A gG for signalling circuit conforming to IEC 60947-5-1, 200 A gG at <= 690 V coordination type 1 for power circuit, 160 A gG at <= 690 V coordination type 2 for power circuit
    • Contactor Application : resistive load, motor control
    • Electrical Durability : 1.2 Mcycles 95 A AC-3, 1.3 Mcycles 125 A AC-1, 1.2 Mcycles 95 A AC-3e
    • Insulation Resistance : > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
    • Mechanical Robustness : vibrations contactor open 2 Gn, 5...300 Hz), shocks contactor open 8 Gn for 11 ms), vibrations contactor closed 3 Gn, 5...300 Hz), shocks contactor closed 10 Gn for 11 ms)
    • Motor Power KW : 45 kW at 380...400 V AC 50 Hz (AC-3e), 45 kW at 415...440 V AC 50 Hz (AC-3e), 55 kW at 500 V AC 50 Hz (AC-3e), 45 kW at 660...690 V AC 50 Hz (AC-3e), 25 kW at 220...230 V AC 50 Hz (AC-3), 45 kW at 380...400 V AC 50 Hz (AC-3), 45 kW at 415...440 V AC 50 Hz (AC-3), 55 kW at 500 V AC 50 Hz (AC-3), 45 kW at 660...690 V AC 50 Hz (AC-3), 15 kW at 400 V AC 50 Hz (AC-4), 25 kW at 220...230 V AC 50 Hz (AC-3e)
    • Mounting Support : rail, plate
    • Non Overlap Time : 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
    • Operating Time : 95...130 ms closing, 20...35 ms opening
    • Power Dissipation Per Pole : 12.5 W AC-1, 7.2 W AC-3, 7.2 W AC-3e
    • Safety Reliability Level : B10d = 1.3 Mcycles contactor with nominal load EN/ISO 13849-1, B10d = 20 Mcycles contactor with mechanical load EN/ISO 13849-1
    • Tightening Torque : control circuit 1.2 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.2 N.m screw clamp terminals Philips No 2, power circuit 12 N.m connector flat Ø 6 to Ø 8 mm, power circuit 12 N.m connector hexagonal 4 mm, control circuit 1.2 N.m screw clamp terminals pozidriv No 2
    • Utilisation Category : AC-3, AC-3e, AC-4, AC-1
    • Icw Rated Short Time Withstand Current2 : 1100 A 40 °C - 1 s for power circuit, 800 A 40 °C - 10 s for power circuit, 400 A 40 °C - 1 min for power circuit, 135 A 40 °C - 10 min for power circuit, 140 A - 100 ms for signalling circuit, 120 A - 500 ms for signalling circuit, 100 A - 1 s for signalling circuit
    • Ie Rated Operational Current2 : 95 A (at <60 °C) at <= 440 V AC-3 for power circuit, 125 A (at <60 °C) at <= 1000 V AC-1 for power circuit, 95 A (at <60 °C) at <= 440 V AC-3e for power circuit
    • Ith Conventional Free Air Thermal Current2 : 10 A (at 60 °C) for signalling circuit, 125 A (at 60 °C) for power circuit
    • Uc Control Circuit Voltage2 : 24 V, 24 V DC
    • Ui Rated Insulation Voltage2 : power circuit 1000 V IEC 60947-4-1, signalling circuit 690 V IEC 60947-1
    • Carbon Footprint Of The Distribution Phase A4 : 0.3416810635410429, 0.3 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 6.461453621222985, 6 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0.5 kg CO2 eq., 0.4899056242009124
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 17 kg CO2 eq., 17.320171625437503
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 160 kg CO2 eq., 160.36942028985501
    • Connections Terminals : screw clamp terminals, control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, power circuit: connector 1 4-50 mm² - cable stiffness: flexible without cable end
    • Connections Terminals3 : control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end, power circuit: connector 1 4-50 mm² - cable stiffness: flexible without cable end, power circuit: connector 2 4-25 mm² - cable stiffness: flexible without cable end, power circuit: connector 1 4-50 mm² - cable stiffness: flexible with cable end, power circuit: connector 2 4-16 mm² - cable stiffness: flexible with cable end, power circuit: connector 1 4-50 mm² - cable stiffness: solid without cable end, power circuit: connector 2 4-25 mm² - cable stiffness: solid without cable end
    • Icw Rated Short Time Withstand Current5 : 1100 A 40 °C - 1 s for power circuit, 800 A 40 °C - 10 s for power circuit, 400 A 40 °C - 1 min for power circuit, 135 A 40 °C - 10 min for power circuit, 140 A - 100 ms for signalling circuit, 120 A - 500 ms for signalling circuit, 100 A - 1 s for signalling circuit
    • Ie Rated Operational Current5 : 95 A (at <60 °C) at <= 440 V AC-3 for power circuit, 125 A (at <60 °C) at <= 1000 V AC-1 for power circuit, 95 A (at <60 °C) at <= 440 V AC-3e for power circuit
    • Ith Conventional Free Air Thermal Current5 : 10 A (at 60 °C) for signalling circuit, 125 A (at 60 °C) for power circuit
    • Ui Rated Insulation Voltage5 : power circuit 1000 V IEC 60947-4-1, signalling circuit 690 V IEC 60947-1
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-08-18
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant
    • ROHS EUR Full Compliance Status : Compliant
    • ROHS EUR Full Compliance Status Id : COMPLIANT
    • China ROHS In Scope : No
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Average Impedance : 0.8 mOhm - Ith 125 A 50 Hz for power circuit
    • Coil Technology : without built-in suppressor module
    • Compatibility Code : LC1D
    • Contact Compatibility : M9
    • Device Short Name : LC1D
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Flame Retardance : V1 conforming to UL 94
    • Hold In Power Consumption In W : 22-22 W 20 °C
    • Inrush Power In W : 22-22 W 20 °C)
    • Mechanical Durability : 10 Mcycles
    • Overvoltage Category : III
    • Package Weight Lbs : 2.566 kg
    • Pole Contact Composition : 3 NO
    • Poles Description : 3P
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : contactor
    • Protective Treatment : THIEC 60068-2-30
    • Range : TeSys
    • Range Of Product : TeSys Deca
    • Returnability : Yes
    • Signalling Circuit Frequency : 25...400 Hz
    • Sustainable Packaging : Yes
    • Time Constant : 75 ms
    • Total Lifecycle Carbon Footprint : 185 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Ue Rated Operational Voltage2 : power circuit <= 690 V AC 25...400 Hz
    • Uimp Rated Impulse Withstand Voltage2 : 8 kV IEC 60947
    • Medium Desc : IEC contactor, TeSys Deca, nonreversing, 95A, 60HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VDC coil, open style
    • Stocking Flag : N
    • Product Kit Identifier : N
    • Pep Code : ENVPEP1102005EN
    • Database Version : 2022-01
    • Pep Verification Date : 2025-08-05
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional Unit Description : Switch on and off during 20 years electrical power supply of a downstream installation with an electrical and/or mechanical control. The functional unit is characterized by a type 3P(3NO), a control circuit voltage 230V AC, a power circuit voltage 690V and a rated operational current 80A
    • Functional Unit Unit : unit
    • Energy Model Manufacturing A1 A3 2 : Electricity Mix; Production mix; Low voltage; CZ
    • Energy Model Installation A5 2 : Electricity Mix; Production mix; Low voltage; FR
    • Energy Model Use B6 2 : Electricity Mix; Production mix; Low voltage; FR
    • Energy Model End Of Life C1 C4 2 : Electricity Mix; Production mix; Low voltage; FR
    • Global Commercial Status : Commercialised
    • Uc Control Circuit Voltage5 : 24 V DC
    • Ue Rated Operational Voltage5 : power circuit <= 690 V AC 25...400 Hz
    • Uimp Rated Impulse Withstand Voltage5 : 8 kV IEC 60947
  • Environment Attributes Main
    • Take Back : Nej, No
    • China ROHS Regulation : Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
    • EU ROHS Directive : Compliant , Compliant
    • Permissible Ambient Air Temperature Around The Device : -40-60 °C, -40-60 °C, 60-70 °C with derating
    • ROHS Exemption Information : Yes
    • Reach Free SHVC : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 184.98263222425743
    • Climatic Withstand : IACS E10 exposure to damp heat
    • Environmental Disclosure : ENVPEP1102005EN
    • IP Degree Of Protection : IP20 front face IEC 60529
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Free Of SVHC : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1102005EN
    • Pep Verification Date : 2025-08-05
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : contactor
    • Range Of Product : TeSys Deca
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Country of Origin : United States
    • Depth : 186 mm