IEC contactor, TeSys Deca, nonreversing, 80A, 60HP at 480VAC, 3 phase, 3 pole, 3 NO, 348VDC coil, open style

CONTACTOR 600VAC 80AMP IEC +OP

SQDLC1D806VD LC1D806VD 3389118093294
513.89 / EA
http://schema.org/OutOfStock
  • Country of Origin: Czechia
  • Depth: 186 mm
  • Height: 127 mm
  • Net Weight: 2.59 kg
  • Warranty Length: 18 mth
  • Weight: 2.59 kg
  • Width: 85 mm
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 80A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. Contactor is supplied with a 348 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 5.12 inches deep. It weighs 3.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.
QTY
  • Product Description
  • Features
  • Specifications
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 80A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. Contactor is supplied with a 348 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 5.12 inches deep. It weighs 3.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Environment
    • Product Certifications : CCC || UL || CB Scheme || CSA || CE || UKCA || Marine || EAC
    • Height : 127 mm
    • Standards : EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || CSA C22.2 No 14 || UL 60947-4-1 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ || IEC 60335-1:Clause 30.2
    • Climatic Withstand : IACS E10 exposure to damp heat
    • Net Weight : 2.59 kg
    • Flame Retardance : V1 conforming to UL 94
    • Protective Treatment : THIEC 60068-2-30
    • Ip Degree Of Protection : IP20 front face IEC 60529
    • Mechanical Robustness : vibrations contactor open 2 Gn, 5...300 Hz) || shocks contactor open 8 Gn for 11 ms) || vibrations contactor closed 3 Gn, 5...300 Hz) || shocks contactor closed 10 Gn for 11 ms)
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Width : 85 mm
    • Depth : 186 mm
    • Permissible Ambient Air Temperature Around The Device : -40-60 °C || 60-70 °C with derating
  • Contractual warranty
    • Warranty : 18 months
  • Environmental data
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP110205EN
    • Packaging Without Single Use Plastic : Yes
    • Toxic Heavy Metal Free : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
    • Reach Free Of Svhc : Yes
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Circularity Profile : N/A
    • Take-Back : No
    • Pvc Free : Yes
    • Sustainable Packaging : Yes
    • Eu Rohs Directive : Compliant
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 100.91826350957028
  • Complementary
    • Non-Overlap Time : 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
    • Minimum Switching Current : 5 mA for signalling circuit
    • Power Dissipation Per Pole : 5.1 W AC-3 || 12.5 W AC-1 || 5.1 W AC-3e
    • Average Impedance : 0.8 mOhm - Ith 125 A 50 Hz for power circuit
    • Auxiliary Contact Composition : 1 NO + 1 NC
    • [Ith] Conventional Free Air Thermal Current : 10 A (at 60 °C) for signalling circuit || 125 A (at 60 °C) for power circuit
    • Control Circuit Voltage Limits : 0.1...0.3 Uc (-40-70 °C):drop-out DC || 0.85...1.1 Uc (-40-55 °C):operational DC || 1...1.1 Uc (55-70 °C):operational DC
    • Mounting Support : rail || plate
    • Control Circuit Type : DC standard
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Pollution Degree : 3
    • Hold-In Power Consumption In W : 22-22 W 20 °C
    • Insulation Resistance : > 10 MOhm for signalling circuit
    • Rated Breaking Capacity : 1100 A at 440 V for power circuit conforming to IEC 60947
    • Irms Rated Making Capacity : 140 A AC for signalling circuit conforming to IEC 60947-5-1 || 250 A DC for signalling circuit conforming to IEC 60947-5-1 || 1100 A at 440 V for power circuit conforming to IEC 60947
    • Associated Fuse Rating : 10 A gG for signalling circuit conforming to IEC 60947-5-1 || 200 A gG at <= 690 V coordination type 1 for power circuit || 160 A gG at <= 690 V coordination type 2 for power circuit
    • [Uimp] Rated Impulse Withstand Voltage : 8 kV IEC 60947
    • Pole Contact Composition : 3 NO
    • Connections - Terminals : control circuit: lugs-ring terminals - external diameter: 8 mm || power circuit: bars 1 - busbar cross section: 3 x 16 mm || power circuit: lugs-ring terminals - external diameter: 17 mm
    • Coil Technology : without built-in suppressor module
    • Time Constant : 75 ms
    • Operating Time : 95...130 ms closing || 20...35 ms opening
    • Minimum Switching Voltage : 17 V for signalling circuit
    • Maximum Operating Rate : 3600 cyc/h at 60 °C
    • Signalling Circuit Frequency : 25...400 Hz
    • Tightening Torque : control circuit 1.2 N.m lugs-ring terminals flat Ø 6 mm M3.5 || control circuit 1.2 N.m lugs-ring terminals Philips No 2 M3.5 || power circuit 5 N.m lugs-ring terminals flat Ø 8 mm M6 || power circuit 5 N.m lugs-ring terminals hexagonal 10 mm M6 || power circuit 5 N.m bars flat Ø 8 mm M6 || power circuit 5 N.m bars hexagonal 10 mm M6 || control circuit 1.2 N.m lugs-ring terminals pozidriv No 2 M3.5
    • Electrical Durability : 0.8 Mcycles 125 A AC-1 <= 440 V || 1.5 Mcycles 80 A AC-3 <= 440 V || 1.5 Mcycles 80 A AC-3e <= 440 V
    • Mechanical Durability : 4 Mcycles
    • Inrush Power In W : 22-22 W 20 °C)
    • Auxiliary Contacts Type : mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
    • Compatibility Code : LC1D
    • Overvoltage Category : III
    • Maximum Horse Power Rating : 7.5 hp at 120 V AC 50/60 Hz for 1 phase motors || 15 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 30 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 30 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 60 hp at 460/480 V AC 50/60 Hz for 3 phase motors || 60 hp at 575/600 V AC 50/60 Hz for 3 phase motors
    • Motor Power Kw : 22 kW at 220...230 V AC 50/60 Hz (AC-3) || 37 kW at 380...400 V AC 50/60 Hz (AC-3) || 45 kW at 415...440 V AC 50/60 Hz (AC-3) || 55 kW at 500 V AC 50/60 Hz (AC-3) || 45 kW at 660...690 V AC 50/60 Hz (AC-3) || 15 kW at 400 V AC 50/60 Hz (AC-4) || 22 kW at 220...230 V AC 50/60 Hz (AC-3e) || 37 kW at 380...400 V AC 50/60 Hz (AC-3e) || 45 kW at 415...440 V AC 50/60 Hz (AC-3e) || 55 kW at 500 V AC 50/60 Hz (AC-3e) || 45 kW at 660...690 V AC 50/60 Hz (AC-3e)
    • [Ui] Rated Insulation Voltage : power circuit 600 V CSA || power circuit 600 V UL || power circuit 1000 V IEC 60947-4-1 || signalling circuit 690 V IEC 60947-1 || signalling circuit 600 V CSA || signalling circuit 600 V UL
    • [Icw] Rated Short-Time Withstand Current : 640 A 40 °C - 10 s for power circuit || 990 A 40 °C - 1 s for power circuit || 135 A 40 °C - 10 min for power circuit || 320 A 40 °C - 1 min for power circuit || 100 A - 1 s for signalling circuit || 120 A - 500 ms for signalling circuit || 140 A - 100 ms for signalling circuit
    • Protective Cover : with
  • Specifications
    • Country of Origin : Czechia
    • Width : 85 mm
    • Height : 127 mm
    • Weight : 2.59 kg
    • [Uc] Control Circuit Voltage : 348 V DC
    • [Ue] Rated Operational Voltage : power circuit <= 300 V DC 25...400 Hz || power circuit <= 690 V AC
    • Range Of Product : TeSys Deca
    • Contactor Application : motor control || resistive load
    • Product Or Component Type : contactor
    • Range : TeSys
    • Utilisation Category : AC-3 || AC-3e || AC-4 || AC-1
    • [Ie] Rated Operational Current : 125 A (at <60 °C) at <= 1000 V AC AC-1 for power circuit || 80 A (at <60 °C) at <= 440 V AC AC-3 for power circuit || 80 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
    • Poles Description : 3P
    • Device Short Name : LC1D