IEC contactor, TeSys Deca, nonreversing, 80A, 60HP at 480VAC, 3 phase, 3 pole, 3 NO, 120VAC 50/60Hz coil, open style

CONTACTOR 600VAC 80AMP IEC +OP

SQDLC1D806G7 LC1D806G7 3389110298246
629.42 / EA
http://schema.org/OutOfStock
  • Depth: 130 mm
  • Warranty Length: 18 mth
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 80A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. Contactor is supplied with a 120 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 5.12 inches deep. It weighs 3.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.
QTY
  • Product Description
  • Features
  • Specifications
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 80A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. Contactor is supplied with a 120 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 5.12 inches deep. It weighs 3.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • Control Circuit Voltage Limits : 0.85...1.1 Uc (-40-55 °C):operational AC 60 Hz, 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz0.8...1.1 Uc (-40-55 °C):operational AC 50 Hz1...1.1 Uc (55-70 °C):operational AC 50/60 Hz
    • Maximum Horse Power Rating : 30 hp at 230/240 V AC 50/60 Hz for 3 phase motors7.5 hp at 120 V AC 50/60 Hz for 1 phase motors15 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 30 hp at 200/208 V AC 50/60 Hz for 3 phase motors60 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 60 hp at 575/600 V AC 50/60 Hz for 3 phase motors
    • Control Circuit Type : AC 50/60 Hz
    • Irms Rated Making Capacity : 140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-11100 A at 440 V for power circuit conforming to IEC 60947
    • Maximum Motor Phase Current : 80 A
    • Maximum Operating Rate : 3600 cyc/h at 60 °C
    • Minimum Switching Current : 5 mA for signalling circuit
    • Minimum Switching Voltage : 17 V for signalling circuit
    • Rated Breaking Capacity : 1100 A at 440 V for power circuit conforming to IEC 60947
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SI
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Contactor Application : motor control, resistive load
    • Electrical Durability : 0.8 Mcycles 125 A AC-1 <= 440 V, 1.5 Mcycles 80 A AC-3 <= 440 V, 1.5 Mcycles 80 A AC-3e <= 440 V
    • Inrush Power In Va : 245-245 VA 60 Hz cos phi 0.75 (at 20 °C), 245-245 VA 50 Hz cos phi 0.75 (at 20 °C)
    • Insulation Resistance : > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
    • Mechanical Robustness : vibrations contactor open 2 Gn, 5...300 Hz)shocks contactor open 8 Gn for 11 ms)vibrations contactor closed 3 Gn, 5...300 Hz), shocks contactor closed 10 Gn for 11 ms)
    • Motor Power Kw : 37 kW at 380...400 V AC 50/60 Hz (AC-3e), 45 kW at 415...440 V AC 50/60 Hz (AC-3e), 55 kW at 500 V AC 50/60 Hz (AC-3e), 45 kW at 660...690 V AC 50/60 Hz (AC-3e)22 kW at 220...230 V AC 50/60 Hz (AC-3)37 kW at 380...400 V AC 50/60 Hz (AC-3)45 kW at 415...440 V AC 50/60 Hz (AC-3)55 kW at 500 V AC 50/60 Hz (AC-3), 45 kW at 660...690 V AC 50/60 Hz (AC-3), 15 kW at 400 V AC 50/60 Hz (AC-4), 22 kW at 220...230 V AC 50/60 Hz (AC-3e)
    • Mounting Support : rail, plate
    • Power Dissipation Per Pole : 5.1 W AC-312.5 W AC-1, 5.1 W AC-3e
    • Tightening Torque : power circuit 5 N.m bars hexagonal 10 mm M6, control circuit 1.2 N.m lugs-ring terminals flat Ø 6 mm M3.5, control circuit 1.2 N.m lugs-ring terminals Philips No 2 M3.5power circuit 5 N.m lugs-ring terminals flat Ø 8 mm M6power circuit 5 N.m lugs-ring terminals hexagonal 10 mm M6, power circuit 5 N.m bars flat Ø 8 mm M6, control circuit 1.2 N.m lugs-ring terminals pozidriv No 2 M3.5
    • Utilisation Category : AC-3, AC-3e, AC-4, AC-1
    • Control Circuit Voltage : 120 V
    • Certificate Agency : CCC, UL, CB Scheme, CSA, CE, UKCA, Marine, EAC
    • [Ie] Rated Operational Current : 125 A (at <60 °C) at <= 1000 V AC AC-1 for power circuit, 80 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 80 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
    • [Uc] Control Circuit Voltage : 120 V, 120 V AC 50/60 Hz
    • [Ui] Rated Insulation Voltage : signalling circuit 600 V CSA, signalling circuit 600 V ULpower circuit 600 V CSA, power circuit 600 V ULpower circuit 1000 V IEC 60947-4-1, signalling circuit 690 V IEC 60947-1
    • Connections - Terminals : lugs-ring terminals, control circuit: lugs-ring terminals - external diameter: 8 mmpower circuit: bars 1 - busbar cross section: 3 x 16 mm, power circuit: lugs-ring terminals - external diameter: 17 mm
    • Hold-in Power Consumption In Va : 26-26 VA 60 Hz cos phi 0.3 (at 20 °C), 26-26 VA 50 Hz cos phi 0.3 (at 20 °C)
    • Non-overlap Time : 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
    • Carbon Footprint Of The Distribution Phase [A4] : 0.21622581342878092, 0.2 kg CO2 eq.
    • Carbon Footprint Of The End-of-life Phase [C1 To C4] : 4.088997647987764, 4 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase [A5] : 0.3 kg CO2 eq., 0.31002666931072853
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 11 kg CO2 eq., 10.960713361237987
    • Carbon Footprint Of The Use Phase [B2, B3, B4, B6] : 81 kg CO2 eq., 80.91632246376808
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-06-27
    • Return Indicator : Y
    • Stocking Flag : N
    • Stock Policy : 2
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant
    • Rohs Eur Conformity Date : 1924
    • Rohs Eur Full Compliance Status : Compliant
    • China Rohs In Scope : No
    • China Rohs Label : 1
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Associated Fuse Rating : 10 A gG for signalling circuit conforming to IEC 60947-5-1200 A gG at <= 690 V coordination type 1 for power circuit160 A gG at <= 690 V coordination type 2 for power circuit
    • Average Impedance : 0.8 mOhm - Ith 125 A 50 Hz for power circuit
    • Coil Technology : without built-in suppressor module
    • Compatibility Code : LC1D
    • Contact Compatibility : M11
    • Device Short Name : LC1D
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Flame Retardance : V1 conforming to UL 94
    • Heat Dissipation : 6-10 W at 50/60 Hz
    • Mechanical Durability : 4 Mcycles
    • Number Of Poles : 3P
    • Operating Time : 20...35 ms closing6...20 ms opening
    • Overvoltage Category : III
    • Pole Contact Composition : 3 NO
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : contactor
    • Protective Treatment : THIEC 60068-2-30
    • Range : TeSys
    • Range Of Product : TeSys Deca
    • Returnability : Yes
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Signalling Circuit Frequency : 25...400 Hz
    • Software Version : v5.9.4
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 96 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Inf Motor Phase Current : 80 A
    • Pep Code : ENVPEP1102005EN
    • Database Version : 2022-01
    • Pep Verification Date : 2025-08-05
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional-unit Description : Switch on and off during 20 years electrical power supply of a downstream installation with an electrical and/or mechanical control. The functional unit is characterized by a type 3P(3NO), a control circuit voltage 230V AC, a power circuit voltage 690V and a rated operational current 80A
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unit
    • Reference Lifetime, In Y : 20
    • Energy Consumption On Product Lifetime, In Kwh : 1211.07
    • Energy Model - Manufacturing [A1-a3] : Electricity Mix; Production mix; Low voltage; CZ
    • Energy Model - Installation [A5] : Electricity Mix; Production mix; Low voltage; FR
    • Energy Model - Use [B6] : Electricity Mix; Production mix; Low voltage; FR
    • Energy Model - End Of Life [C1-c4] : Electricity Mix; Production mix; Low voltage; FR
    • Recyclability Potential, In % : 76
    • Height Nominal : 127 mm
    • Width Nominal : 85 mm
    • [Icw] Rated Short-time Withstand Current : 640 A 40 °C - 10 s for power circuit990 A 40 °C - 1 s for power circuit135 A 40 °C - 10 min for power circuit320 A 40 °C - 1 min for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit
    • [Ith] Conventional Free Air Thermal Current : 10 A (at 60 °C) for signalling circuit125 A (at 60 °C) for power circuit
    • [Ue] Rated Operational Voltage : power circuit <= 300 V DC 25...400 Hzpower circuit <= 690 V AC
    • [Uimp] Rated Impulse Withstand Voltage : 8 kV IEC 60947
    • Nbr. Of Units In Pkg. : 1
    • Package Weight(Lbs) : 1.397 kg
    • Take-back : No
    • Warranty (In Months) : 18
    • Customs Code : 8536490065
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Take Back : No
    • Reach Free Shvc : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 96.49228595573335
    • Climatic Withstand : IACS E10 exposure to damp heat
    • Environmental Disclosure : ENVPEP1102005EN
    • Eu Rohs Directive : Compliant
    • Ip Degree Of Protection : IP20 front face IEC 60529
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Permissible Ambient Air Temperature Around The Device : -40-60 °C-40-60 °C60-70 °C with derating
    • Reach Free Of Svhc : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1102005EN
    • Pep Verification Date : 2025-08-05
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : contactor
    • Range Of Product : TeSys Deca
  • ETIM
    • ETIM 8 : EC000066
    • ETIM 9 : EC000066
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Country of Origin : Czechia, United States
    • Depth : 130 mm