Schneider Electric at Mayer

IEC contactor, TeSys D, nonreversing, 40A, 30HP at 480VAC, 3 phase, 3 pole, 3 NO, 240VAC 50/60Hz coil, open style

TeSys D 3P Everlink AC CONTR A

SQDLC1D40A6U7 LC1D40A6U7 785901023517
298.08 / EACH
  • Certifications: CCC, CSA, GOST, UKCA, UL
  • Contact Configuration: 3 NO
  • Contact Configuration: 1 NO + 1 NC
  • Depth: 120 mm
  • Height: 122 mm
  • Impedance: 1.5 MOhm - Ith 60 A 50 Hz Power Circuit
  • Net Weight: 0.85 kg
  • Standard: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508
  • Storage Temperature: -60-80 °C
  • Warranty Length: 18 mth
  • Width: 55 mm
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 40A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 10HP at 200 to 208VAC, 10HP at 240VAC, 30HP at 480VAC and 30HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 5HP at 240VAC single phase. Contactor is supplied with a 240 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
  • Product Description
  • Specifications
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 40A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 10HP at 200 to 208VAC, 10HP at 240VAC, 30HP at 480VAC and 30HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 5HP at 240VAC single phase. Contactor is supplied with a 240 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
  • Control Circuit Type : AC 50/60 Hz
  • [Ie] Rated Operational Current : 60 A 60 °C) <= 440 V AC AC-1 power circuit || 40 A 60 °C) <= 440 V AC AC-3 power circuit
  • Tightening Torque : control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5 || control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5 || power circuit 6 N.m lugs-ring terminals hexagonal 10 mm M6
  • [Ue] Rated Operational Voltage : power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
  • [Icw] Rated Short-Time Withstand Current : 320 A 40 °C - 10 s power circuit || 720 A 40 °C - 1 s power circuit || 72 A 40 °C - 10 min power circuit || 165 A 40 °C - 1 min power circuit || 100 A - 1 s signalling circuit || 120 A - 500 ms signalling circuit || 140 A - 100 ms signalling circuit
  • Auxiliary Contact Composition : 1 NO + 1 NC
  • Product Or Component Type : contactor
  • Electrical Durability : 1.4 Mcycles 60 A AC-1 <= 440 V || 1.5 Mcycles 40 A AC-3 <= 440 V
  • Range : TeSys
  • Pole Contact Composition : 3 NO
  • Overvoltage Category : III
  • Motor Power Kw : 18.5 kW 380...400 V AC 50/60 Hz AC-3) || 11 kW 220...230 V AC 50/60 Hz AC-3) || 22 kW 415...440 V AC 50/60 Hz AC-3) || 22 kW 500 V AC 50/60 Hz AC-3) || 30 kW 660...690 V AC 50/60 Hz AC-3) || 9 kW 400 V AC 50/60 Hz AC-4)
  • [Ith] Conventional Free Air Thermal Current : 10 A 60 °C signalling circuit || 60 A 60 °C power circuit
  • [Ui] Rated Insulation Voltage : power circuit 600 V CSA || power circuit 600 V UL || signalling circuit 690 V IEC 60947-1 || signalling circuit 600 V CSA || signalling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
  • Contactor Application : motor control || resistive load
  • Irms Rated Making Capacity : 140 A AC signalling circuit IEC 60947-5-1 || 250 A DC signalling circuit IEC 60947-5-1 || 800 A 440 V power circuit IEC 60947
  • Device Short Name : LC1D
  • Protective Cover : with
  • Average Impedance : 1.5 mOhm - Ith 60 A 50 Hz power circuit
  • Product Name : TeSys D
  • Mechanical Durability : 6 Mcycles
  • Associated Fuse Rating : 10 A gG signalling circuit IEC 60947-5-1 || 80 A gG <= 690 V type 1 power circuit || 80 A gG <= 690 V type 2 power circuit
  • Connections - Terminals : control circuit lugs-ring terminals 8 mm) || power circuit lugs-ring terminals 16.5 mm)
  • Utilisation Category : AC-3 || AC-4 || AC-1
  • Rated Breaking Capacity : 800 A 440 V power circuit IEC 60947
  • [Uc] Control Circuit Voltage : 240 V AC 50/60 Hz
  • Mounting Support : plate || rail
  • Power Dissipation Per Pole : 2.4 W AC-3 || 5.4 W AC-1
  • Maximum Horse Power Rating : 5 hp 230/240 V at AC 50/60 Hz for 1 phase || 10 hp 230/240 V at AC 50/60 Hz for 3 phase || 30 hp 575/600 V at AC 50/60 Hz for 3 phase || 10 hp 200/208 V at AC 50/60 Hz for 3 phase || 3 hp 115 V at AC 50/60 Hz for 1 phase || 30 hp 460/480 V at AC 50/60 Hz for 3 phase
  • [Uimp] Rated Impulse Withstand Voltage : 6 kV IEC 60947
  • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • Operating Time : 4...19 ms opening || 12...26 ms closing
  • Poles Description : 3P
  • Product Certifications : CCC || GOST || CSA || UL || UKCA
  • Standards : CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508
  • Maximum Operating Rate : 3600 cyc/h 60 °C
  • Offer Sustainability
    • Sustainable Offer Status : Green Premium product
    • Mercury Free : Yes
    • Circularity Profile : ENVEOLI1503009EN
    • Toxic Heavy Metal Free : Yes
    • Rohs Exemption Information : Yes
    • Pvc Free : Yes
    • Environmental Disclosure : ENVPEP1503009EN
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Reach Free Of Svhc : Yes
    • China Rohs Regulation : Pro-active China RoHS declaration (out of China RoHS legal scope)
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
    • Eu Rohs Directive : Compliant
  • Environment
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Depth : 120 mm
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Height : 122 mm
    • Ip Degree Of Protection : IP20 front face IEC 60529
    • Flame Retardance : V1 conforming to UL 94
    • Net Weight : 0.85 kg
    • Ambient Air Temperature For Operation : -40-60 °C || 60-70 °C with derating
    • Mechanical Robustness : vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor closed15 Gn for 11 ms || shocks contactor open10 Gn for 11 ms
    • Pollution Degree : 3
    • Width : 55 mm
    • Ambient Air Temperature For Storage : -60-80 °C
    • Protective Treatment : TH IEC 60068-2-30
  • Contractual warranty
    • Warranty : 18 months
  • Complementary
    • Signalling Circuit Frequency : 25...400 Hz
    • Inrush Power In Va : 140-140 VA 60 Hz 0.75 20 °C) || 160-160 VA 50 Hz 0.75 20 °C)
    • Auxiliary Contacts Type : mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
    • Control Circuit Voltage Limits : 0.3...0.6 Uc -40-70 °C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60 °C operational AC 50 Hz || 0.85...1.1 Uc -40-60 °C operational AC 60 Hz || 1...1.1 Uc 60-70 °C operational AC 50/60 Hz
    • Hold-In Power Consumption In Va : 13-13 VA 60 Hz 0.3 20 °C) || 15-15 VA 50 Hz 0.3 20 °C)
    • Minimum Switching Voltage : 17 V signalling circuit
    • Heat Dissipation : 4-5 W 50/60 Hz
    • Coil Technology : without built-in suppressor module
    • Non-Overlap Time : 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
    • Minimum Switching Current : 5 mA signalling circuit