IEC contactor, TeSys D, nonreversing, 40A, 30HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 24VDC coil, open style

TESYS D 3P EVERLINK DC CONTACT

SQDLC1D40ABD LC1D40ABD 785901929826
300.82 / EACH
  • Certifications: CCC, CSA, GOST, UKCA, UL
  • Contact Configuration: 1 NO + 1 NC, 3 NO
  • Depth: 120 mm
  • Height: 122 mm
  • Impedance: 1.5 MOhm - Ith 60 A 50 Hz Power Circuit
  • Net Weight: 0.925 kg
  • Standard: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508
  • Storage Temperature: -60-80 °C
  • Warranty Length: 18 mth
  • Width: 55 mm
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 40A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 10HP at 200 to 208VAC, 10HP at 240VAC, 30HP at 480VAC and 30HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 5HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 90A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
  • Product Description
  • Specifications
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 40A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 10HP at 200 to 208VAC, 10HP at 240VAC, 30HP at 480VAC and 30HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 5HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 90A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
  • Environment
    • Mechanical Robustness : vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor closed15 Gn for 11 ms || shocks contactor open10 Gn for 11 ms
    • Height : 122 mm
    • Protective Treatment : TH IEC 60068-2-30
    • Ambient Air Temperature For Storage : -60-80 °C
    • Ambient Air Temperature For Operation : -40-60 °C || 60-70 °C with derating
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Flame Retardance : V1 conforming to UL 94
    • Net Weight : 0.925 kg
    • Ip Degree Of Protection : IP20 front face IEC 60529
    • Depth : 120 mm
    • Width : 55 mm
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Pollution Degree : 3
  • Average Impedance : 1.5 mOhm - Ith 60 A 50 Hz power circuit
  • Product Certifications : CCC || CSA || GOST || UL || UKCA
  • Tightening Torque : control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm || power circuit 5 N.m EverLink BTR screw connectors 1-25 mm² hexagonal 4 mm
  • Poles Description : 3P
  • Motor Power Kw : 18.5 kW 380...400 V AC 50/60 Hz AC-3) || 11 kW 220...230 V AC 50/60 Hz AC-3) || 22 kW 415...440 V AC 50/60 Hz AC-3) || 22 kW 500 V AC 50/60 Hz AC-3) || 30 kW 660...690 V AC 50/60 Hz AC-3) || 9 kW 400 V AC 50/60 Hz AC-4)
  • Pole Contact Composition : 3 NO
  • Control Circuit Type : DC standard
  • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • [Ui] Rated Insulation Voltage : power circuit 600 V CSA || power circuit 600 V UL || signalling circuit 690 V IEC 60947-1 || signalling circuit 600 V CSA || signalling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
  • Auxiliary Contact Composition : 1 NO + 1 NC
  • Contactor Application : resistive load || motor control
  • Product Or Component Type : contactor
  • Protective Cover : with
  • Mechanical Durability : 10 Mcycles
  • Maximum Operating Rate : 3600 cyc/h 60 °C
  • Irms Rated Making Capacity : 140 A AC signalling circuit IEC 60947-5-1 || 250 A DC signalling circuit IEC 60947-5-1 || 800 A 440 V power circuit IEC 60947
  • Operating Time : 42.5...57.5 ms closing || 16...24 ms opening
  • [Icw] Rated Short-Time Withstand Current : 320 A 40 °C - 10 s power circuit || 720 A 40 °C - 1 s power circuit || 72 A 40 °C - 10 min power circuit || 165 A 40 °C - 1 min power circuit || 100 A - 1 s signalling circuit || 120 A - 500 ms signalling circuit || 140 A - 100 ms signalling circuit
  • [Ith] Conventional Free Air Thermal Current : 10 A 60 °C signalling circuit || 60 A 60 °C power circuit
  • [Uc] Control Circuit Voltage : 24 V DC
  • [Uimp] Rated Impulse Withstand Voltage : 6 kV IEC 60947
  • [Ie] Rated Operational Current : 60 A 60 °C) <= 440 V AC AC-1 power circuit || 40 A 60 °C) <= 440 V AC AC-3 power circuit
  • Utilisation Category : AC-1 || AC-3 || AC-4
  • Overvoltage Category : III
  • Power Dissipation Per Pole : 2.4 W AC-3 || 5.4 W AC-1
  • Range : TeSys
  • Device Short Name : LC1D
  • Standards : CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508
  • Mounting Support : rail || plate
  • Product Name : TeSys D
  • Maximum Horse Power Rating : 5 hp 230/240 V at AC 50/60 Hz for 1 phase || 10 hp 230/240 V at AC 50/60 Hz for 3 phase || 30 hp 575/600 V at AC 50/60 Hz for 3 phase || 10 hp 200/208 V at AC 50/60 Hz for 3 phase || 3 hp 115 V at AC 50/60 Hz for 1 phase || 30 hp 460/480 V at AC 50/60 Hz for 3 phase
  • Connections - Terminals : control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²solid without cable end || control circuit screw clamp terminals 2 1-4 mm²solid without cable end || power circuit screw connection 1 1-35 mm²flexible without cable end || power circuit screw connection 2 1-25 mm²flexible without cable end || power circuit screw connection 1 1-35 mm²flexible with cable end || power circuit screw connection 2 1-25 mm²flexible with cable end || power circuit screw connection 1 1-35 mm²solid without cable end || power circuit screw connection 2 1-25 mm²solid without cable end
  • Associated Fuse Rating : 10 A gG signalling circuit IEC 60947-5-1 || 80 A gG <= 690 V type 1 power circuit || 80 A gG <= 690 V type 2 power circuit
  • [Ue] Rated Operational Voltage : power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
  • Rated Breaking Capacity : 800 A 440 V power circuit IEC 60947
  • Electrical Durability : 0.7 Mcycles 60 A AC-1 <= 440 V || 1.5 Mcycles 40 A AC-3 <= 440 V
  • Contractual warranty
    • Warranty : 18 months
  • Complementary
    • Signalling Circuit Frequency : 25...400 Hz
    • Inrush Power In W : 19-19 W 20 °C)
    • Hold-In Power Consumption In W : 7.4-7.4 W 20 °C
    • Control Circuit Voltage Limits : 0.1...0.3 Uc -40-70 °C drop-out DC || 0.75...1.25 Uc -40-60 °C operational DC || 1...1.25 Uc 60-70 °C operational DC
    • Time Constant : 34 ms
    • Insulation Resistance : > 10 MOhm signalling circuit
    • Non-Overlap Time : 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
    • Minimum Switching Voltage : 17 V signalling circuit
    • Coil Technology : built-in bidirectional peak limiting diode suppressor
    • Auxiliary Contacts Type : mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
    • Minimum Switching Current : 5 mA signalling circuit
  • Offer Sustainability
    • Eu Rohs Directive : Compliant
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
    • Sustainable Offer Status : Green Premium product
    • Rohs Exemption Information : Yes
    • Circularity Profile : ENVEOLI1503009EN
    • Toxic Heavy Metal Free : Yes
    • Reach Free Of Svhc : Yes
    • China Rohs Regulation : Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP1503009EN
    • Pvc Free : Yes