IEC contactor, TeSys D, nonreversing, 150A, 100HP at 480VAC, 3 phase, 3 pole, 3 NO, 110VAC 50/60Hz coil, open style

CONTACTOR 600VAC 150AMP IEC +O

SQDLC1D1506F7 LC1D1506F7 785901508304
761.32 / EA
  • Certifications: BV, CCC, CSA, DNV, GL, GOST, LROS (Lloyds Register Of Shipping), RINA, UKCA, UL
  • Contact Configuration: 1 NO + 1 NC, 3 NO
  • Depth: 136 mm
  • Height: 158 mm
  • Impedance: 0.6 MOhm - Ith 200 A 50 Hz Power Circuit
  • Net Weight: 2.5 kg
  • Standard: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508
  • Storage Temperature: -60-80 °C
  • Warranty Length: 18 mth
  • Width: 120 mm
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 150A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 40HP at 200 to 208VAC, 50HP at 240VAC, 100HP at 480VAC and 125HP at 600VAC three phase. Contactor is supplied with a 110 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 6.22 inches tall, 4.72 inches wide and 5.35 inches deep. It weighs 5.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
  • Product Description
  • Specifications
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 150A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 40HP at 200 to 208VAC, 50HP at 240VAC, 100HP at 480VAC and 125HP at 600VAC three phase. Contactor is supplied with a 110 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 6.22 inches tall, 4.72 inches wide and 5.35 inches deep. It weighs 5.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
  • Environment
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Ambient Air Temperature For Storage : -60-80 °C
    • Pollution Degree : 3
    • Protective Treatment : TH IEC 60068-2-30
    • Height : 158 mm
    • Net Weight : 2.5 kg
    • Depth : 136 mm
    • Ip Degree Of Protection : IP20 front face IEC 60529
    • Ambient Air Temperature For Operation : -40-60 °C || 60-70 °C with derating
    • Mechanical Robustness : vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor closed15 Gn for 11 ms || shocks contactor open6 Gn for 11 ms
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Flame Retardance : V1 conforming to UL 94
    • Width : 120 mm
  • Offer Sustainability
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
    • Sustainable Offer Status : Green Premium product
    • China Rohs Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Rohs Exemption Information : Yes
    • Environmental Disclosure : ENVPEP060301EN
    • Pvc Free : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Circularity Profile : ENVEOLI100405EN
    • Mercury Free : Yes
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Eu Rohs Directive : Compliant
  • Poles Description : 3P
  • Utilisation Category : AC-1 || AC-4 || AC-3
  • [Ue] Rated Operational Voltage : power circuit <= 1000 V AC 25...400 Hz || power circuit <= 300 V DC
  • Product Certifications : RINA || BV || CSA || LROS (Lloyds register of shipping) || GOST || UL || GL || DNV || CCC || UKCA
  • Range : TeSys
  • Tightening Torque : control circuit 1.2 N.m lugs-ring terminals flat Ø 6 mm M3.5 || control circuit 1.2 N.m lugs-ring terminals Philips No 2 M3.5 || power circuit 12 N.m lugs-ring terminals hexagonal 13 mm M8 || power circuit 12 N.m bars hexagonal 13 mm M8
  • Maximum Horse Power Rating : 40 hp 200/208 V at AC 50/60 Hz for 3 phase || 50 hp 230/240 V at AC 50/60 Hz for 3 phase || 100 hp 460/480 V at AC 50/60 Hz for 3 phase || 125 hp 575/600 V at AC 50/60 Hz for 3 phase
  • Power Dissipation Per Pole : 24 W AC-1 || 13.5 W AC-3
  • Product Name : TeSys D
  • [Ui] Rated Insulation Voltage : power circuit 600 V CSA || power circuit 600 V UL || power circuit 1000 V IEC 60947-4-1 || signalling circuit 690 V IEC 60947-1 || signalling circuit 600 V CSA || signalling circuit 600 V UL
  • [Icw] Rated Short-Time Withstand Current : 250 A 40 °C - 10 min power circuit || 580 A 40 °C - 1 min power circuit || 1200 A 40 °C - 10 s power circuit || 1400 A 40 °C - 1 s power circuit || 100 A - 1 s signalling circuit || 120 A - 500 ms signalling circuit || 140 A - 100 ms signalling circuit
  • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • Mechanical Durability : 8 Mcycles
  • [Ith] Conventional Free Air Thermal Current : 200 A 60 °C power circuit
  • Standards : CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508
  • [Ie] Rated Operational Current : 200 A 60 °C) <= 440 V AC AC-1 power circuit || 150 A 60 °C) <= 440 V AC AC-3 power circuit
  • [Uc] Control Circuit Voltage : 110 V AC 50/60 Hz
  • Rated Breaking Capacity : 1400 A 440 V power circuit IEC 60947
  • Contactor Application : motor control || resistive load
  • Electrical Durability : 0.85 Mcycles 150 A AC-3 <= 440 V || 1 Mcycles 200 A AC-1 <= 440 V
  • Auxiliary Contact Composition : 1 NO + 1 NC
  • Device Short Name : LC1D
  • Motor Power Kw : 40 kW 220...230 V AC 50/60 Hz AC-3) || 75 kW 380...400 V AC 50/60 Hz AC-3) || 80 kW 415...440 V AC 50/60 Hz AC-3) || 90 kW 500 V AC 50/60 Hz AC-3) || 100 kW 660...690 V AC 50/60 Hz AC-3) || 75 kW 1000 V AC 50/60 Hz AC-3) || 22 kW 400 V AC 50/60 Hz AC-4)
  • Control Circuit Type : AC 50/60 Hz
  • Connections - Terminals : control circuit lugs-ring terminals 8 mm) || power circuit lugs-ring terminals 25 mm) || power circuit bars 1 5 x 25 mm
  • Protective Cover : with
  • Overvoltage Category : III
  • Operating Time : 20...35 ms closing || 40...75 ms opening
  • Average Impedance : 0.6 mOhm - Ith 200 A 50 Hz power circuit
  • Maximum Operating Rate : 1200 cyc/h 60 °C
  • Mounting Support : rail || plate
  • Irms Rated Making Capacity : 140 A AC signalling circuit IEC 60947-5-1 || 250 A DC signalling circuit IEC 60947-5-1 || 1660 A 440 V power circuit IEC 60947
  • Pole Contact Composition : 3 NO
  • Product Or Component Type : contactor
  • Associated Fuse Rating : 10 A gG signalling circuit IEC 60947-5-1 || 315 A gG <= 690 V type 1 power circuit || 250 A gG <= 690 V type 2 power circuit
  • [Uimp] Rated Impulse Withstand Voltage : 8 kV IEC 60947
  • Contractual warranty
    • Warranty : 18 months
  • Complementary
    • Auxiliary Contacts Type : mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
    • Minimum Switching Voltage : 17 V signalling circuit
    • Non-Overlap Time : 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
    • Inrush Power In Va : 280-350 VA 60 Hz 0.9 20 °C) || 280-350 VA 50 Hz 0.9 20 °C)
    • Minimum Switching Current : 5 mA signalling circuit
    • Coil Technology : built-in bidirectional peak limiting diode suppressor
    • Control Circuit Voltage Limits : 0.3...0.5 Uc -40-70 °C drop-out AC 50/60 Hz || 0.8...1.15 Uc -40-55 °C operational AC 50/60 Hz || 1...1.15 Uc 55-70 °C operational AC 50/60 Hz
    • Heat Dissipation : 3-4.5 W 50/60 Hz
    • Insulation Resistance : > 10 MOhm signalling circuit
    • Hold-In Power Consumption In Va : 2-18 VA 60 Hz 0.9 20 °C) || 2-18 VA 50 Hz 0.9 20 °C)
    • Signalling Circuit Frequency : 25...400 Hz