IEC contactor, TeSys D Green, nonreversing, 50A, 40HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 24/60VAC/VDC coil, open

TESYS D CTR, 50A, 24-60VAC/DC

SQDLC1D50ABNE LC1D50ABNE 785901765295
141.11 / EA
  • Certifications: CCC, CSA, DNV-GL, EAC, KC, LROS (Lloyds Register Of Shipping), UKCA, UL
  • Contact Configuration: 1 NO + 1 NC, 3 NO
  • Depth: 120 mm
  • Height: 122 mm
  • Impedance: 1.5 MOhm - Ith 80 A 50 Hz Power Circuit
  • Net Weight: 0.997 kg
  • Standard: CSA C22.2 No 60947-4-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 60947-4-1
  • Storage Temperature: -60-80 °C
  • Warranty Length: 18 mth
  • Width: 55 mm
TeSys D Green contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 50A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 15HP at 200 to 208VAC, 15HP at 240VAC, 40HP at 480VAC and 40HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 7.5HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 110A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Equipped with an electronic coil, wide band voltage 24-60V, AC/DC compatible, low consumption. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
  • Product Description
  • Specifications
TeSys D Green contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 50A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 15HP at 200 to 208VAC, 15HP at 240VAC, 40HP at 480VAC and 40HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 7.5HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 110A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Equipped with an electronic coil, wide band voltage 24-60V, AC/DC compatible, low consumption. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
  • [Ui] Rated Insulation Voltage : power circuit 690 V IEC 60947-4-1 || signalling circuit 690 V IEC 60947-1
  • Contactor Application : resistive load || motor control
  • Auxiliary Contact Composition : 1 NO + 1 NC
  • [Ue] Rated Operational Voltage : power circuit <= 690 V AC 25...400 Hz
  • Mechanical Durability : 6 Mcycles
  • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • [Ie] Rated Operational Current : 80 A 60 °C) <= 440 V AC-1 power circuit || 50 A 60 °C) <= 440 V AC-3 power circuit || 50 A 60 °C) <= 440 V AC-3e power circuit
  • Product Certifications : CCC || CSA || EAC || UL || KC || DNV-GL || LROS (Lloyds register of shipping) || UKCA
  • Product Or Component Type : contactor
  • Coil Type : AC/DC electronic
  • Motor Power Kw : 15 kW 220...230 V AC 50 Hz AC-3) || 22 kW 380...400 V AC 50 Hz AC-3) || 25 kW 415 V AC 50 Hz AC-3) || 30 kW 440 V AC 50 Hz AC-3) || 30 kW 500 V AC 50 Hz AC-3) || 33 kW 660...690 V AC 50 Hz AC-3) || 15 kW 220...230 V AC 50 Hz AC-3e) || 22 kW 380...400 V AC 50 Hz AC-3e) || 25 kW 415 V AC 50 Hz AC-3e) || 30 kW 440 V AC 50 Hz AC-3e) || 30 kW 500 V AC 50 Hz AC-3e) || 33 kW 660...690 V AC 50 Hz AC-3e)
  • Maximum Operating Rate : 3600 cyc/h 60 °C
  • [Icw] Rated Short-Time Withstand Current : 100 A - 1 s signalling circuit || 120 A - 500 ms signalling circuit || 140 A - 100 ms signalling circuit || 84 A 40 °C - 10 min power circuit || 208 A 40 °C - 1 min power circuit || 400 A 40 °C - 10 s power circuit || 810 A 40 °C - 1 s power circuit
  • Utilisation Category : AC-1 || AC-3 || AC-3e
  • Average Impedance : 1.5 mOhm - Ith 80 A 50 Hz power circuit
  • Device Short Name : LC1D
  • Electrical Durability : 1.8 Mcycles 42 A AC-3 <= 440 V || 0.5 Mcycles 80 A AC-1 <= 440 V || 1.8 Mcycles 42 A AC-3e <= 440 V
  • [Uimp] Rated Impulse Withstand Voltage : 6 kV IEC 60947
  • [Uc] Control Circuit Voltage : 24...60 V AC 50/60 Hz || 24...60 V DC
  • Overvoltage Category : III
  • [Ith] Conventional Free Air Thermal Current : 80 A 60 °C power circuit || 10 A 60 °C signalling circuit
  • Standards : EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1
  • Maximum Horse Power Rating : 3 hp 115 V at AC 60 Hz for 1 phase || 7.5 hp 230/240 V at AC 60 Hz for 1 phase || 15 hp 200/208 V at AC 60 Hz for 3 phase || 15 hp 230/240 V at AC 60 Hz for 3 phase || 40 hp 460/480 V at AC 60 Hz for 3 phase || 40 hp 575/600 V at AC 60 Hz for 3 phase
  • Connections - Terminals : control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²solid || control circuit screw clamp terminals 2 1-4 mm²solid || power circuit EverLink BTR screw connectors 1 1-35 mm²flexible without cable end || power circuit EverLink BTR screw connectors 1 1-35 mm²flexible with cable end || power circuit EverLink BTR screw connectors 1 1-35 mm²solid || power circuit EverLink BTR screw connectors 2 1-25 mm²flexible without cable end || power circuit EverLink BTR screw connectors 2 1-25 mm²flexible with cable end || power circuit EverLink BTR screw connectors 2 1-25 mm²solid
  • Pole Contact Composition : 3 NO
  • Protective Cover : with
  • Product Name : TeSys D Green
  • Associated Fuse Rating : 10 A gG signalling circuit IEC 60947-5-1 || 100 A gG <= 690 V type 1 power circuit || 100 A gG <= 690 V type 2 power circuit
  • Tightening Torque : control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm || power circuit 5 N.m EverLink BTR screw connectors 1-25 mm² hexagonal 4 mm
  • Rated Breaking Capacity : 900 A 440 V power circuit IEC 60947
  • Irms Rated Making Capacity : 900 A 440 V power circuit IEC 60947 || 140 A AC signalling circuit IEC 60947-5-1 || 250 A DC signalling circuit IEC 60947-5-1
  • Power Dissipation Per Pole : 9.6 W AC-1 || 3.7 W AC-3 || 3.7 W AC-3e
  • Poles Description : 3P
  • Operating Time : 55...65 ms closing || 20...120 ms opening >= 17221) || 20...80 ms opening >= 18011)
  • Mounting Support : rail || plate
  • Range : TeSys
  • Contractual warranty
    • Warranty : 18 months
  • Environment
    • Flame Retardance : V1 conforming to UL 94
    • Ambient Air Temperature For Storage : -60-80 °C
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Ip Degree Of Protection : IP20 front face IEC 60529
    • Color : Gray SE GREY 6) || Green SE GREEN 2)
    • Height : 122 mm
    • Depth : 120 mm
    • Protective Treatment : TH IEC 60068-2-30
    • Ambient Air Temperature For Operation : -40-60 °C || 60-70 °C with derating
    • Pollution Degree : 3
    • Net Weight : 0.997 kg
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Width : 55 mm
    • Mechanical Robustness : vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor open10 Gn for 11 ms || shocks contactor closed15 Gn for 11 ms
  • Offer Sustainability
    • China Rohs Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Rohs Exemption Information : Yes
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Sustainable Offer Status : Green Premium product
    • Circularity Profile : ENVEOLI1607010EN
    • Halogen Content Performance : Halogen free plastic parts & cables product
    • Eu Rohs Directive : Compliant
    • Environmental Disclosure : ENVPEP1607010EN
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Mercury Free : Yes
  • Complementary
    • Insulation Resistance : > 10 MOhm signalling circuit
    • Hold-In Power Consumption In W : 0.7-0.7 W 20 °C
    • Auxiliary Contacts Type : mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
    • Inrush Power In Va : 15-15 VA 50/60 Hz 20 °C)
    • Inrush Power In W : 16-16 W 20 °C
    • Coil Technology : built-in bidirectional peak limiting
    • Minimum Switching Current : 5 mA signalling circuit
    • Minimum Switching Voltage : 17 V signalling circuit
    • Signalling Circuit Frequency : 25...400 Hz
    • Heat Dissipation : 0.7-0.7 W 50/60 Hz
    • Control Circuit Voltage Limits : <= 0.1 Uc -40-70 °C drop-out AC/DC || 0.85...1.1 Uc -40-60 °C operational AC || 0.8...1.1 Uc -40-60 °C operational DC || 1...1.1 Uc 60-70 °C operational AC/DC
    • Hold-In Power Consumption In Va : 1-1 VA 20 °C) 50/60 Hz
    • Non-Overlap Time : 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact