Schneider Electric at Mayer

IEC contactor, TeSys Deca, reversing, 25A resistive, 4 pole, 4 NO, 120VAC 50/60Hz coil, open style

IEC contactor, TeSys Deca, reversing, 25A resistive, 4 pole, 4 NO, 120VAC 50/60Hz coil, open style

SQDLC2DT25G7 LC2DT25G7 3389110515886
478.01 / EA
http://schema.org/OutOfStock
  • Warranty Length: 18 mth
TeSys Deca contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys Deca contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This reversing 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 25A resistive load rating. Contactor is supplied with a 120 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 3.54 inches wide and 3.54 inches deep. It weighs 1.61 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.
QTY
  • Product Description
  • Features
  • Specifications
TeSys Deca contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys Deca contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This reversing 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 25A resistive load rating. Contactor is supplied with a 120 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 3.54 inches wide and 3.54 inches deep. It weighs 1.61 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Conformance Attributes
    • Standards : CSA C22.2 No 60947-4-1, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 60947-4-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.4
  • Complementary Attributes
    • Control Circuit Type : AC 50/60 Hz, AC 50/60 Hz
    • Control Circuit Voltage Limits : 0.3...0.6 Uc (-40-60 °C):drop-out AC 50/60 Hz, 0.3...0.6 Uc (-40-60 °C):drop-out AC 50/60 Hz, 0.3...0.6 Uc (-40-60 °C):drop-out AC 50/60 Hz, 0.3...0.6 Uc (-40-60 °C):drop-out AC 50/60 Hz, 0.3...0.6 Uc (-40-60 °C):drop-out AC 50/60 Hz, 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz, 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz, 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz, 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz, 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz, 0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz, 0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz, 0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz, 0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz, 0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz
    • IRMS Rated Making Capacity : 250 A at 440 V for power circuit conforming to IEC 60947, 250 A at 440 V for power circuit conforming to IEC 60947, 250 A at 440 V for power circuit conforming to IEC 60947, 250 A at 440 V for power circuit conforming to IEC 60947, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1
    • Maximum Operating Rate : 3600 cyc/h 60 °C, 3600 cyc/h 60 °C
    • Minimum Switching Current : 5 mA for signalling circuit, 5 mA for signalling circuit
    • Minimum Switching Voltage : 17 V for signalling circuit, 17 V for signalling circuit
    • Rated Breaking Capacity : 250 A at 440 V for power circuit conforming to IEC 60947, 250 A at 440 V for power circuit conforming to IEC 60947, 250 A at 440 V for power circuit conforming to IEC 60947, 250 A at 440 V for power circuit conforming to IEC 60947
    • ICW Rated Short Time Withstand Current : 30 A 40 °C - 10 min for power circuit, 30 A 40 °C - 10 min for power circuit, 30 A 40 °C - 10 min for power circuit, 30 A 40 °C - 10 min for power circuit, 61 A 40 °C - 1 min for power circuit, 61 A 40 °C - 1 min for power circuit, 61 A 40 °C - 1 min for power circuit, 61 A 40 °C - 1 min for power circuit, 105 A 40 °C - 10 s for power circuit, 105 A 40 °C - 10 s for power circuit, 105 A 40 °C - 10 s for power circuit, 105 A 40 °C - 10 s for power circuit, 210 A 40 °C - 1 s for power circuit, 210 A 40 °C - 1 s for power circuit, 210 A 40 °C - 1 s for power circuit, 210 A 40 °C - 1 s for power circuit, 100 A - 1 s for signalling circuit, 100 A - 1 s for signalling circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 120 A - 500 ms for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit, 140 A - 100 ms for signalling circuit, 140 A - 100 ms for signalling circuit
    • IE Rated Operational Current : 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
    • UC Control Circuit Voltage : 120 V AC 50/60 Hz, 120 V AC 50/60 Hz, 120 V AC 50/60 Hz
    • UE Rated Operational Voltage : power circuit <= 690 V AC 25...400 Hz, power circuit <= 690 V AC 25...400 Hz, power circuit <= 690 V AC 25...400 Hz, power circuit <= 690 V AC 25...400 Hz, power circuit <= 300 V DC, power circuit <= 300 V DC, power circuit <= 300 V DC
    • UI Rated Insulation Voltage : power circuit 690 V IEC 60947-4-1, power circuit 690 V IEC 60947-4-1, power circuit 690 V IEC 60947-4-1, power circuit 600 V CSA, power circuit 600 V CSA, power circuit 600 V CSA, power circuit 600 V UL, power circuit 600 V UL, power circuit 600 V UL, signalling circuit 690 V IEC 60947-1, signalling circuit 690 V IEC 60947-1, signalling circuit 690 V IEC 60947-1, signalling circuit 600 V CSA, signalling circuit 600 V CSA, signalling circuit 600 V CSA, signalling circuit 600 V UL, signalling circuit 600 V UL, signalling circuit 600 V UL
    • UIMP Rated Impulse Withstand Voltage : 6 kV IEC 60947, 6 kV IEC 60947
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SI
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Associated Fuse Rating : 10 A gG for signalling circuit conforming to IEC 60947-5-1, 10 A gG for signalling circuit conforming to IEC 60947-5-1, 10 A gG for signalling circuit conforming to IEC 60947-5-1, 10 A gG for signalling circuit conforming to IEC 60947-5-1, 40 A gG at <= 690 V coordination type 1 for power circuit, 40 A gG at <= 690 V coordination type 1 for power circuit, 40 A gG at <= 690 V coordination type 1 for power circuit, 40 A gG at <= 690 V coordination type 1 for power circuit, 40 A gG at <= 690 V coordination type 1 for power circuit, 25 A gG at <= 690 V coordination type 2 for power circuit, 25 A gG at <= 690 V coordination type 2 for power circuit, 25 A gG at <= 690 V coordination type 2 for power circuit, 25 A gG at <= 690 V coordination type 2 for power circuit, 25 A gG at <= 690 V coordination type 2 for power circuit
    • Average Impedance : 2.5 mOhm - Ith 25 A 50 Hz for power circuit, 2.5 mOhm - Ith 25 A 50 Hz for power circuit, 2.5 mOhm - Ith 25 A 50 Hz for power circuit, 2.5 mOhm - Ith 25 A 50 Hz for power circuit
    • Electrical Durability : 0.8 Mcycles 25 A AC-1 <= 690 V, 0.8 Mcycles 25 A AC-1 <= 690 V, 0.8 Mcycles 25 A AC-1 <= 690 V, 0.8 Mcycles 25 A AC-1 <= 690 V
    • Fire Resistance : 850 °C IEC 60695-2-1, 850 °C IEC 60695-2-1
    • Flame Retardance : V1 conforming to UL 94, V1 conforming to UL 94
    • Heat Dissipation : 2-3 W 50/60 Hz, 2-3 W 50/60 Hz
    • Hold In Power Consumption In VA : 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20 °C), 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20 °C), 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20 °C), 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20 °C), 7-7 VA 50 Hz cos phi 0.3 (at 20 °C), 7-7 VA 50 Hz cos phi 0.3 (at 20 °C), 7-7 VA 50 Hz cos phi 0.3 (at 20 °C), 7-7 VA 50 Hz cos phi 0.3 (at 20 °C)
    • Inrush Power In VA : 70-70 VA 60 Hz cos phi 0.75 (at 20 °C), 70-70 VA 60 Hz cos phi 0.75 (at 20 °C), 70-70 VA 60 Hz cos phi 0.75 (at 20 °C), 70-70 VA 60 Hz cos phi 0.75 (at 20 °C), 70-70 VA 50 Hz cos phi 0.75 (at 20 °C), 70-70 VA 50 Hz cos phi 0.75 (at 20 °C), 70-70 VA 50 Hz cos phi 0.75 (at 20 °C), 70-70 VA 50 Hz cos phi 0.75 (at 20 °C)
    • Insulation Resistance : > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
    • Mechanical Robustness : vibrations contactor open2 Gn, 5...300 Hz, vibrations contactor open2 Gn, 5...300 Hz, vibrations contactor open2 Gn, 5...300 Hz, vibrations contactor closed4 Gn, 5...300 Hz, vibrations contactor closed4 Gn, 5...300 Hz, vibrations contactor closed4 Gn, 5...300 Hz, shocks contactor open10 Gn for 11 ms, shocks contactor open10 Gn for 11 ms, shocks contactor open10 Gn for 11 ms, shocks contactor closed15 Gn for 11 ms, shocks contactor closed15 Gn for 11 ms, shocks contactor closed15 Gn for 11 ms
    • Non Overlap Time : 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
    • Operating Time : 12...22 ms closing, 12...22 ms closing, 4...19 ms opening, 4...19 ms opening
    • Power Dissipation Per Pole : 1.56 W AC-1, 1.56 W AC-1
    • Protective Treatment : TH IEC 60068-2-30, TH IEC 60068-2-30
    • Range : TeSys, TeSys Deca
    • Range Of Product : TeSys D, TeSys Deca
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Tightening Torque : power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, power circuit 1.7 N.m screw clamp terminals Philips No 2, power circuit 1.7 N.m screw clamp terminals Philips No 2, power circuit 1.7 N.m screw clamp terminals Philips No 2, power circuit 1.7 N.m screw clamp terminals Philips No 2, control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals Philips No 2, control circuit 1.7 N.m screw clamp terminals Philips No 2, control circuit 1.7 N.m screw clamp terminals Philips No 2, control circuit 1.7 N.m screw clamp terminals Philips No 2, control circuit 1.7 N.m screw clamp terminals pozidriv No 2, control circuit 1.7 N.m screw clamp terminals pozidriv No 2, control circuit 1.7 N.m screw clamp terminals pozidriv No 2, control circuit 1.7 N.m screw clamp terminals pozidriv No 2, power circuit 2.5 N.m screw clamp terminals pozidriv No 2, power circuit 2.5 N.m screw clamp terminals pozidriv No 2, power circuit 2.5 N.m screw clamp terminals pozidriv No 2, power circuit 2.5 N.m screw clamp terminals pozidriv No 2
    • ICW Rated Short Time Withstand Current : 30 A 40 °C - 10 min for power circuit, 30 A 40 °C - 10 min for power circuit, 30 A 40 °C - 10 min for power circuit, 30 A 40 °C - 10 min for power circuit, 61 A 40 °C - 1 min for power circuit, 61 A 40 °C - 1 min for power circuit, 61 A 40 °C - 1 min for power circuit, 61 A 40 °C - 1 min for power circuit, 105 A 40 °C - 10 s for power circuit, 105 A 40 °C - 10 s for power circuit, 105 A 40 °C - 10 s for power circuit, 105 A 40 °C - 10 s for power circuit, 210 A 40 °C - 1 s for power circuit, 210 A 40 °C - 1 s for power circuit, 210 A 40 °C - 1 s for power circuit, 210 A 40 °C - 1 s for power circuit, 100 A - 1 s for signalling circuit, 100 A - 1 s for signalling circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 120 A - 500 ms for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit, 140 A - 100 ms for signalling circuit, 140 A - 100 ms for signalling circuit
    • IE Rated Operational Current : 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
    • ITH Conventional Free Air Thermal Current : 10 A (at 60 °C) for signalling circuit, 10 A (at 60 °C) for signalling circuit, 10 A (at 60 °C) for signalling circuit, 25 A (at 60 °C) for power circuit, 25 A (at 60 °C) for power circuit, 25 A (at 60 °C) for power circuit
    • Carbon Footprint Of The Distribution Phase A4 : 0.33879221429274187, 0.3 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 1.7679946612607658, 2 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0.1 kg CO2 eq., 0.054510314688270035
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 4 kg CO2 eq., 4.360477584613512
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 48 kg CO2 eq., 47.52545236460906
    • Connections Terminals : power circuit screw clamp terminals 1 1-4 mm²flexible without cable end, power circuit screw clamp terminals 1 1-4 mm²flexible without cable end, power circuit screw clamp terminals 1 1-4 mm²flexible without cable end, power circuit screw clamp terminals 1 1-4 mm²flexible without cable end, power circuit screw clamp terminals 1 1-4 mm²flexible without cable end, power circuit screw clamp terminals 1 1-4 mm²flexible without cable end, power circuit screw clamp terminals 2 1-4 mm²flexible without cable end, power circuit screw clamp terminals 2 1-4 mm²flexible without cable end, power circuit screw clamp terminals 2 1-4 mm²flexible without cable end, power circuit screw clamp terminals 2 1-4 mm²flexible without cable end, power circuit screw clamp terminals 2 1-4 mm²flexible without cable end, power circuit screw clamp terminals 2 1-4 mm²flexible without cable end, power circuit screw clamp terminals 1 1-4 mm²flexible with cable end, power circuit screw clamp terminals 1 1-4 mm²flexible with cable end, power circuit screw clamp terminals 1 1-4 mm²flexible with cable end, power circuit screw clamp terminals 1 1-4 mm²flexible with cable end, power circuit screw clamp terminals 1 1-4 mm²flexible with cable end, power circuit screw clamp terminals 1 1-4 mm²flexible with cable end, power circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end, power circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end, power circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end, power circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end, power circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end, power circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end, power circuit screw clamp terminals 1 1-4 mm²solid, power circuit screw clamp terminals 1 1-4 mm²solid, power circuit screw clamp terminals 1 1-4 mm²solid, power circuit screw clamp terminals 1 1-4 mm²solid, power circuit screw clamp terminals 1 1-4 mm²solid, power circuit screw clamp terminals 2 1-4 mm²solid, power circuit screw clamp terminals 2 1-4 mm²solid, power circuit screw clamp terminals 2 1-4 mm²solid, power circuit screw clamp terminals 2 1-4 mm²solid, power circuit screw clamp terminals 2 1-4 mm²solid, control circuit screw clamp terminals 1 1-4 mm²flexible without cable end, control circuit screw clamp terminals 1 1-4 mm²flexible without cable end, control circuit screw clamp terminals 1 1-4 mm²flexible without cable end, control circuit screw clamp terminals 1 1-4 mm²flexible without cable end, control circuit screw clamp terminals 1 1-4 mm²flexible without cable end, control circuit screw clamp terminals 1 1-4 mm²flexible without cable end, control circuit screw clamp terminals 2 1-4 mm²flexible without cable end, control circuit screw clamp terminals 2 1-4 mm²flexible without cable end, control circuit screw clamp terminals 2 1-4 mm²flexible without cable end, control circuit screw clamp terminals 2 1-4 mm²flexible without cable end, control circuit screw clamp terminals 2 1-4 mm²flexible without cable end, control circuit screw clamp terminals 2 1-4 mm²flexible without cable end, control circuit screw clamp terminals 1 1-4 mm²flexible with cable end, control circuit screw clamp terminals 1 1-4 mm²flexible with cable end, control circuit screw clamp terminals 1 1-4 mm²flexible with cable end, control circuit screw clamp terminals 1 1-4 mm²flexible with cable end, control circuit screw clamp terminals 1 1-4 mm²flexible with cable end, control circuit screw clamp terminals 1 1-4 mm²flexible with cable end, control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end, control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end, control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end, control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end, control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end, control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end, control circuit screw clamp terminals 1 1-4 mm²solid, control circuit screw clamp terminals 1 1-4 mm²solid, control circuit screw clamp terminals 1 1-4 mm²solid, control circuit screw clamp terminals 1 1-4 mm²solid, control circuit screw clamp terminals 1 1-4 mm²solid, control circuit screw clamp terminals 2 1-4 mm²solid, control circuit screw clamp terminals 2 1-4 mm²solid, control circuit screw clamp terminals 2 1-4 mm²solid, control circuit screw clamp terminals 2 1-4 mm²solid, control circuit screw clamp terminals 2 1-4 mm²solid
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-09
    • HTML Description : REVERSING CONTACTOR 575VAC 25A IECUtilisation category : AC-1Poles description : 4P Power pole contact composition : 4 NOControl circuit voltage : 120 V AC 50/60 HzRated operational current : 25 A Auxiliary contact composition : 1 NO + 1 NC
    • Manufacturer : Schneider Electric
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1501004
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant
    • ROHS EUR Full Compliance Status : Compliant
    • ROHS EUR Full Compliance Status Id : COMPLIANT
    • China ROHS In Scope : No
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • WD Status : 1 - GSC certified
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Coil Technology : without built-in suppressor module
    • Compatibility Code : LC2D
    • Contact Compatibility : M6
    • Contactor Application : resistive load
    • Device Short Name : LC2D
    • Interlocking Type : mechanical
    • Package Weight Lbs : 852.000 g
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : changeover contactor
    • Returnability : Yes
    • Signalling Circuit Frequency : 25...400 Hz
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 54 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Relationship Type : Compatible relationship
    • Pep Code : ENVPEP1501004EN
    • Pep Verification Date : 2025-08-05
    • PCR Version : PCR-4-ed4-EN-2021 09 06
    • PSR Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
    • Rated Thermal Current Ith : 25 A
    • Functional Unit Description : Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
    • Functional Unit Unit : unit
    • Product Kit Identifier : N
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : -40-60 °C, 60-70 °C with derating, 60-70 °C with derating
    • Climatic Withstand : IACS E10, IEC 60947-1 Annex Q category D
    • EU ROHS Directive : Compliant​, Compliant
    • IP Degree Of Protection : IP20 front face IEC 60529, IP20 front face IEC 60529, IP20 front face IEC 60529
    • Reach Regulation : Free of Substances of Very High Concern above the threshold, Free of Substances of Very High Concern above the threshold
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Reach Free SHVC : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 54.04722713946435
    • Circularity Profile : ENVEOLI1501004
    • Environmental Disclosure : ENVPEP1501004EN
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Free Of SVHC : Yes
    • Pep Code : ENVPEP1501004EN
    • Pep Verification Date : 2025-08-05
    • PCR Version : PCR-4-ed4-EN-2021 09 06
    • PSR Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Range Of Product : TeSys D, TeSys Deca
    • Product Or Component Type : changeover contactor
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Overview Attributes
    • Device Presentation : preassembled, with prewired power connections