IEC contactor, TeSys Deca, nonreversing, 18A, 10HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 110VAC 50/60Hz coil, bulk

CONTACTOR 575VAC 18AMP IEC +OP

SQDLC1D18F7TQ LC1D18F7TQ 3389110123814
187.63 / EA
http://schema.org/OutOfStock
  • Country of Origin: France
  • Depth: 86 mm
  • Height: 77 mm
  • Net Weight: 3.3 kg
  • Warranty Length: 18 mth
  • Weight: 3.3 kg
  • Width: 45 mm
TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 18A/690V AC-3/3e (7.5kW@400V). They can be used to create motor starters for almost any type of application. It provides a 110V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (45mm width), DIN-rail mounting or screw fixing. Pack of 10 units. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). When used with a 480VAC up to 60A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 40A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 110 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.03 inches tall, 1.77 inches wide and 3.39 inches deep. It weighs 0.73 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.
QTY
  • Product Description
  • Features
  • Specifications
TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 18A/690V AC-3/3e (7.5kW@400V). They can be used to create motor starters for almost any type of application. It provides a 110V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (45mm width), DIN-rail mounting or screw fixing. Pack of 10 units. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). When used with a 480VAC up to 60A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 40A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 110 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.03 inches tall, 1.77 inches wide and 3.39 inches deep. It weighs 0.73 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Environment
    • Product Certifications : CCC || GOST || GL || UL || LROS (Lloyds register of shipping) || DNV || BV || RINA || CSA || UKCA
    • Net Weight : 3.3 kg
    • Flame Retardance : V1 conforming to UL 94
    • Operating Altitude : 9842.52 ft (3000 m) without derating
    • Width : 45 mm
    • Depth : 86 mm
    • Permissible Ambient Air Temperature Around The Device : -5-60 °C || -40-70 °C at Uc
    • Height : 77 mm
    • Standards : EN/IEC 60947-4-1 || CSA C22.2 No 14 || EN/IEC 60947-5-1 || UL 508 || IEC 60335-1
    • Climatic Withstand : IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
    • Ip Degree Of Protection : IP2X IEC 60529 || IP2X VDE 0106
    • Mechanical Robustness : shocks contactor opened 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms) || vibrations contactor opened 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz)
    • Quantity Per Set : set of 10
    • Fire Resistance : 850 °C IEC 60695-2-1
  • Contractual warranty
    • Warranty : 18 months
  • Environmental data
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Take-Back : No
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 21.0243378
    • Packaging Made With Recycled Cardboard : Yes
    • Environmental Disclosure : ENVPEP1501004
    • Packaging Without Single Use Plastic : Yes
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
    • Circularity Profile : ENVEOLI1501004
    • Pvc Free : Yes
  • Complementary
    • Non-Overlap Time : 1.5 ms on de-energisation between NC and NO contacts || 1.5 ms on energisation between NC and NO contacts
    • Minimum Switching Current : 5 mA for control circuit
    • Power Dissipation Per Pole : 0.8 W AC-3 || 2.5 W AC-1 || 0.8 W AC-3e
    • Average Impedance : 2.5 mOhm - Ith 32 A 50 Hz for power circuit
    • Auxiliary Contact Composition : 1 NO + 1 NC
    • Mounting Support : rail || plate
    • Insulation Resistance : > 10 MOhm for control circuit
    • Inrush Power In Va : 70-70 VA cos phi 0.75 (at 20 °C)
    • [Uimp] Rated Impulse Withstand Voltage : 6 kV IEC 60947
    • Pole Contact Composition : 3 NO
    • Connections - Terminals : control circuit: screw clamp terminal 1 1-4 mm² - cable stiffness: solid without cable end || control circuit: screw clamp terminal 2 1-4 mm² - cable stiffness: solid without cable end || control circuit: screw clamp terminal 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminal 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminal 1 1-4 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminal 2 1-2.5 mm² - cable stiffness: flexible with cable end || power circuit: screw clamp terminal 1 1.5-6 mm² - cable stiffness: solid without cable end || power circuit: screw clamp terminal 2 1.5-6 mm² - cable stiffness: solid without cable end || power circuit: screw clamp terminal 1 1-6 mm² - cable stiffness: flexible with cable end || power circuit: screw clamp terminal 2 1-4 mm² - cable stiffness: flexible with cable end || power circuit: screw clamp terminal 1 1.5-6 mm² - cable stiffness: flexible without cable end || power circuit: screw clamp terminal 2 1.5-6 mm² - cable stiffness: flexible without cable end
    • Coil Technology : without built-in bidirectional peak limiting diode suppressor
    • Maximum Operating Rate : 3600 cyc/h at 60 °C
    • Hold-In Power Consumption In Va : 7-7 VA 50/60 Hz cos phi 0.3 (at 20 °C)
    • Overvoltage Category : III
    • Maximum Horse Power Rating : 1 hp at 115 V AC 50/60 Hz for 1 phase motors conforming to UL || 1 hp at 115 V AC 50/60 Hz for 1 phase motors conforming to CSA || 10 hp at 460/480 V AC 50/60 Hz for 3 phase motors conforming to CSA || 10 hp at 460/480 V AC 50/60 Hz for 3 phase motors conforming to UL || 15 hp at 575/600 V AC 50/60 Hz for 3 phase motors conforming to CSA || 15 hp at 575/600 V AC 50/60 Hz for 3 phase motors conforming to UL || 5 hp at 200/208 V AC 50/60 Hz for 3 phase motors conforming to CSA || 5 hp at 200/208 V AC 50/60 Hz for 3 phase motors conforming to UL || 3 hp at 230...240 V AC 50/60 Hz for 1 phase motors conforming to CSA || 3 hp at 230...240 V AC 50/60 Hz for 1 phase motors conforming to UL || 5 hp at 230...240 V AC 50/60 Hz for 3 phase motors conforming to CSA || 5 hp at 230...240 V AC 50/60 Hz for 3 phase motors conforming to UL
    • Motor Power Kw : 10 kW at 500 V AC 50/60 Hz || 10 kW at 660...690 V AC 50/60 Hz || 4 kW at 220...230 V AC 50/60 Hz || 7.5 kW at 380...400 V AC 50/60 Hz || 9 kW at 415...440 V AC 50/60 Hz
    • [Ui] Rated Insulation Voltage : control circuit 600 V CSA || control circuit 600 V UL || power circuit 600 V CSA || power circuit 600 V UL || control circuit 690 V IEC 60947-4-1 || power circuit 690 V IEC 60947-4-1
    • Protective Cover : with
    • [Ith] Conventional Free Air Thermal Current : 10 A (at 60 °C) for control circuit || 32 A (at 60 °C) for power circuit
    • Control Circuit Voltage Limits : 0.3...0.6 Uc (60-60 °C):drop-out AC 50/60 Hz || 0.8...1.1 Uc (60-60 °C):operational AC 50 Hz || 0.85...1.1 Uc (60-60 °C):operational AC 60 Hz
    • Control Circuit Type : AC 50/60 Hz
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Rated Breaking Capacity : 300 kA at 440 V for power circuit conforming to IEC 60947
    • Irms Rated Making Capacity : 140 A AC for control circuit conforming to IEC 60947-5-1 || 300 A at 440 V for power circuit conforming to IEC 60947
    • Associated Fuse Rating : 10 A gG for control circuit conforming to IEC 60947-5-1 || 35 A at <= 690 V coordination type 2 for power circuit || 50 A at <= 690 V coordination type 1 for power circuit
    • Operating Time : 4...19 ms opening || 12...22 ms closing
    • Minimum Switching Voltage : 17 V for control circuit
    • Tightening Torque : control circuit 1.7 N.m flat Ø 6 mm || control circuit 1.7 N.m Philips No 2 || power circuit 1.7 N.m flat Ø 6 mm || power circuit 1.7 N.m Philips No 2 || control circuit 1.7 N.m pozidriv No 2 || power circuit 1.7 N.m pozidriv No 2
    • Mechanical Durability : 15000000 cycles
    • Compatibility Code : LC1D
    • Heat Dissipation : 2-3 W at 50/60 Hz for control circuit
  • Specifications
    • Country of Origin : France
    • Width : 45 mm
    • Height : 77 mm
    • Weight : 3.3 kg
    • [Uc] Control Circuit Voltage : 110 V AC 50/60 Hz
    • [Ue] Rated Operational Voltage : power circuit <= 690 V AC 25...400 Hz
    • Contactor Application : resistive load || motor control
    • Product Or Component Type : contactor
    • Utilisation Category : AC-1 || AC-3 || AC-3e
    • [Ie] Rated Operational Current : 32 A (at <60 °C) at <= 440 V AC AC-1 for power circuit || 18 A (at <60 °C) at <= 440 V AC AC-3 for power circuit || 18 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
    • Poles Description : 3P
    • Range Of Product : TeSys Deca
    • Range : TeSys || TeSys Deca
    • Device Short Name : LC1D