IEC contactor, TeSys D, nonreversing, 18A, 10HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 110VAC 50/60Hz coil, bulk

IEC contactor, TeSys D, nonreversing, 18A, 10HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 110VAC 50/60Hz coil, bulk

SQDLC1D18F7TQ LC1D18F7TQ 785901213222
148.77 / EACH
  • Certifications: BV, CCC, CSA, DNV, GL, GOST, LROS (Lloyds Register Of Shipping), RINA, UKCA, UL
  • Contact Configuration: 3 NO
  • Contact Configuration: 1 NO + 1 NC
  • Depth: 86 mm
  • Height: 77 mm
  • Impedance: 2.5 MOhm - Ith 32 A 50 Hz Power Circuit
  • Net Weight: 3.3 kg
  • Standard: CSA C22.2 No 14, EN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 508
  • Storage Temperature: -60-80 °C
  • Warranty Length: 18 mth
  • Width: 45 mm
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 18A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 5HP at 200-208VAC, 5HP at 240VAC, 10HP at 480VAC and 15HP at 600VAC three phase. Contactor is also rated for 1HP at 115VAC and 3HP at 240VAC single phase. When used with a 480VAC up to 60A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 40A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 110 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.03 inches tall, 1.77 inches wide and 3.39 inches deep. It weighs 0.73 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
  • Product Description
  • Specifications
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 18A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 5HP at 200-208VAC, 5HP at 240VAC, 10HP at 480VAC and 15HP at 600VAC three phase. Contactor is also rated for 1HP at 115VAC and 3HP at 240VAC single phase. When used with a 480VAC up to 60A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 40A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 110 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.03 inches tall, 1.77 inches wide and 3.39 inches deep. It weighs 0.73 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
  • Complementary
    • Minimum Switching Voltage : 17 V control circuit
    • Associated Fuse Rating : 10 A gG control circuit IEC 60947-5-1 || 35 A <= 690 V type 2 power circuit || 50 A <= 690 V type 1 power circuit
    • Auxiliary Contact Composition : 1 NO + 1 NC
    • Power Dissipation Per Pole : 0.8 W AC-3 || 2.5 W AC-1
    • Insulation Resistance : > 10 MOhm control circuit
    • Maximum Operating Rate : 3600 cyc/h 60 °C
    • Inrush Power In Va : 70-70 VA 0.75 20 °C)
    • Mechanical Durability : 15000000 cycles
    • Average Impedance : 2.5 mOhm - Ith 32 A 50 Hz power circuit
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Overvoltage Category : III
    • Maximum Width : 45 mm
    • [Ith] Conventional Free Air Thermal Current : 10 A 60 °C control circuit || 32 A 60 °C power circuit
    • Protective Cover : with
    • Minimum Switching Current : 5 mA control circuit
    • Irms Rated Making Capacity : 140 A AC control circuit IEC 60947-5-1 || 300 A 440 V power circuit IEC 60947
    • Operating Time : 4...19 ms opening || 12...22 ms closing
    • Net Weight : 3.3 kg
    • Control Circuit Voltage Limits : drop-out 0.3...0.6 Uc 50/60 Hz 60 °C) || operational 0.8...1.1 Uc 50 Hz 60 °C) || operational 0.85...1.1 Uc 60 Hz 60 °C)
    • [Ue] Rated Operational Voltage : power circuit <= 690 V AC 25...400 Hz
    • Flame Retardance : V1 conforming to UL 94
    • [Uimp] Rated Impulse Withstand Voltage : 6 kV IEC 60947
    • Maximum Depth : 86 mm
    • Non-Overlap Time : 1.5 ms on de-energisation between NC and NO contacts || 1.5 ms on energisation between NC and NO contacts
    • Tightening Torque : control circuit 1.7 N.m flat Ø 6 mm || control circuit 1.7 N.m Philips No 2 || power circuit 1.7 N.m flat Ø 6 mm || power circuit 1.7 N.m Philips No 2
    • Mounting Support : rail || plate
    • Hold-In Power Consumption In Va : 7-7 VA 50/60 Hz 0.3 20 °C)
    • Coil Technology : without built-in bidirectional peak limiting diode suppressor
    • Maximum Height : 77 mm
    • Rated Breaking Capacity : 300 kA 440 V power circuit IEC 60947
    • [Ui] Rated Insulation Voltage : control circuit 600 V CSA || control circuit 600 V UL || power circuit 600 V CSA || power circuit 600 V UL || control circuit 690 V IEC 60947-4-1 || power circuit 690 V IEC 60947-4-1
  • Environment
    • Standards : EN/IEC 60947-4-1 || CSA C22.2 No 14 || EN/IEC 60947-5-1 || UL 508
    • Operating Altitude : 9842.52 ft (3000 m) without derating
    • Ip Degree Of Protection : IP2x IEC 60529 || IP2x VDE 0106
    • Heat Dissipation : 2-3 W 50/60 Hz control circuit
    • Shock Resistance : 10 gn contactor opened || 15 gn contactor closed
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Vibration Resistance : 2 gn 5-300 Hz contactor opened || 4 gn 5-300 Hz contactor closed
    • Ambient Air Temperature For Storage : -60-80 °C
    • Product Certifications : CCC || GOST || GL || UL || LROS (Lloyds register of shipping) || DNV || BV || RINA || CSA || UKCA
    • Permissible Ambient Air Temperature Around The Device : -40-70 °C at Uc
    • Ambient Air Temperature For Operation : -5-60 °C
  • Control Circuit Type : AC 50/60 Hz
  • Product Or Component Type : contactor
  • Motor Power Kw : 10 kW 500 V AC 50/60 Hz || 10 kW 660...690 V AC 50/60 Hz || 4 kW 220...230 V AC 50/60 Hz || 7.5 kW 380...400 V AC 50/60 Hz || 9 kW 415...440 V AC 50/60 Hz
  • Contactor Application : resistive load || motor control
  • [Uc] Control Circuit Voltage : 110 V AC 50/60 Hz
  • Quantity Per Set : set of 10
  • Range Of Product : TeSys D
  • Range : TeSys
  • Utilisation Category : AC-1 || AC-3
  • [Ie] Rated Operational Current : 32 A 60 °C) <= 440 V AC AC-1 power circuit || 18 A 60 °C) <= 440 V AC AC-3 power circuit
  • Maximum Horse Power Rating : 1 hp 115 V AC 50/60 Hz 1P UL || 1 hp 115 V AC 50/60 Hz 1P CSA || 10 hp 460/480 V AC 50/60 Hz 3P CSA || 10 hp 460/480 V AC 50/60 Hz 3P UL || 15 hp 575/600 V AC 50/60 Hz 3P CSA || 15 hp 575/600 V AC 50/60 Hz 3P UL || 5 hp 200/208 V AC 50/60 Hz 3P CSA || 5 hp 200/208 V AC 50/60 Hz 3P UL || 3 hp 230...240 V AC 50/60 Hz 1P CSA || 3 hp 230...240 V AC 50/60 Hz 1P UL || 5 hp 230...240 V AC 50/60 Hz 3P CSA || 5 hp 230...240 V AC 50/60 Hz 3P UL
  • Pole Contact Composition : 3 NO
  • Poles Description : 3P
  • Device Short Name : LC1D
  • Connections - Terminals : control circuit screw clamp terminal 1 x 1-4 mm²solid without cable end || control circuit screw clamp terminal 2 x 1-4 mm²flexible without cable end || control circuit screw clamp terminal 2 x 1-4 mm²solid without cable end || control circuit spring terminal 1 x 2.5-2.5 mm²flexible without cable end || control circuit spring terminal 2 x 2.5-2.5 mm²flexible without cable end || control circuit screw clamp terminal 1 x 1-4 mm²flexible without cable end || control circuit screw clamp terminal 1 x 1-4 mm²flexible with cable end || control circuit screw clamp terminal 2 x 1-2.5 mm²flexible with cable end || power circuit ring lugs 8 mm) || control circuit ring lugs 8 mm) || power circuit screw clamp terminal 1 x 1-6 mm²flexible with cable end || power circuit screw clamp terminal 1 x 1.5-6 mm²flexible without cable end || power circuit screw clamp terminal 1 x 1.5-6 mm²solid without cable end || power circuit screw clamp terminal 2 x 1.5-6 mm²solid without cable end || power circuit spring terminal 1 x 4-4 mm²flexible without cable end || power circuit screw clamp terminal 2 x 1.5-6 mm²flexible without cable end || power circuit screw clamp terminal 2 x 1-4 mm²flexible with cable end || power circuit spring terminal 2 x 4-4 mm²
  • Offer Sustainability
    • Circularity Profile : ENVEOLI1501004EN
    • Mercury Free : Yes
    • Reach Free Of Svhc : Yes
    • Eu Rohs Directive : Compliant
    • Sustainable Offer Status : Green Premium product
    • Pvc Free : Yes
    • Environmental Disclosure : ENVPEP1501004EN
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • China Rohs Regulation : Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
    • Rohs Exemption Information : Yes
    • Toxic Heavy Metal Free : Yes
  • Contractual warranty