Schneider Electric at Mayer

Relay - 600 V 10 Amp Tesys + Options

Relay 600v 10 Amp Tesys + Opti

SQDCAD32G7TQ CAD32G7TQ 3389110847208
72.71 / EA
http://schema.org/OutOfStock
  • Warranty Length: 18 mth
TeSys Deca control relay, 5 contacts (3NO + 2NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13. It provides a 120V 50/60Hz AC control circuit, connection by screw clamp terminals. For high operating rates until 180 cycles/min and ambient temperature -40/+60°C, it procures high reliability and durability. Compact (45mm width), for clipping on 35mm DIN rail or fixing by screw. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine).
QTY
  • Product Description
  • Features
  • Specifications
TeSys Deca control relay, 5 contacts (3NO + 2NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13. It provides a 120V 50/60Hz AC control circuit, connection by screw clamp terminals. For high operating rates until 180 cycles/min and ambient temperature -40/+60°C, it procures high reliability and durability. Compact (45mm width), for clipping on 35mm DIN rail or fixing by screw. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine).
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • Control Circuit Voltage Limits : drop-out: 0.3...0.6 Uc, operational: 0.8...1.1 Uc at 50 Hz, operational: 0.85...1.1 Uc at 60 Hz
    • UE Rated Operational Voltage : <= 690 V AC 25...400 Hz, <= 690 V AC 25...400 Hz, <= 690 V AC 25...400 Hz
    • UI Rated Insulation Voltage : 600 VCSA, 600 VUL, 690 V III 3) IEC 60947-5-1
    • IRMS Rated Making Capacity : 140 A <= 690 V AC IEC 60947-5-1
    • Maximum Operating Rate : 3 cyc/s 20 °C
    • UC Control Circuit Voltage : 120 V AC 50/60 Hz
    • UIMP Rated Impulse Withstand Voltage : 6 kV IEC 60947
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder
    • Non Overlap Time : 1.5 ms on de-energisation between NC and NO contacts, 1.5 ms on energisation between NC and NO contacts
    • Operating Time : 12...22 ms coil energisation and NO closing, 4...12 ms coil de-energisation and NO opening, 4...19 ms coil energisation and NC opening, 6...17 ms coil de-energisation and NC closing
    • Range : TeSys, TeSys Deca
    • Range Of Product : TeSys Deca control relay, TeSys Deca
    • Shock Resistance : 10 gn control relay open, 15 gn control relay closed
    • Vibration Resistance : 2 gn 5-300 Hz control relay open, 4 gn 5-300 Hz control relay closed
    • Carbon Footprint Of The Distribution Phase A4 : 0.26917737573943873, 0.3 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 1 kg CO2 eq., 1.4047080870291015
    • Carbon Footprint Of The Installation Phase A5 : 0.04330956509478989, 0 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 3 kg CO2 eq., 3.464489039829913
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 11 kg CO2 eq., 11.413132033372865
    • Connections Terminals : 1 x 1-4 mm²flexible with cable end, 1 x 1-4 mm²flexible without cable end, 1 x 1-4 mm²solid without cable end, 2 x 1-2.5 mm²flexible with cable end, 2 x 1-4 mm²flexible without cable end
    • Auxiliaries : LADN22, LADN11, LADN20, LAD8N11, LADT2, LADN40, LADN31, LADN02, LADT0
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-30
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1501004
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status Id : COMPLIANT_WITH_EXEMPTIONS
    • China ROHS In Scope : No
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • WD Status : 5 - INITIALIZED WITH DataSCAN OK (Migration)
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Market Segmentation Id : INDUSTRIAL
    • Market Segmentation : Industrial
    • Associated Fuse Rating : 10 A gG <= 690 V IEC 60947-5-1
    • Coil Type : standard
    • Compatibility Code : CAD
    • Contact Operation : mechanically linked IEC 60947-5-1
    • Contactor Application : control circuit
    • Device Short Name : CAD
    • Hold In Power Consumption In VA : 8-8 VA 50 Hz (at 20 °C)
    • Inrush Power In VA : 70-70 VA (at 20 °C)
    • Package Weight Lbs : 352.0 g
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : auxiliary contactor
    • Protective Treatment : TH IEC 60068
    • Returnability : Yes
    • Suppressor Technology : without built-in
    • Sustainable Packaging : Yes
    • Tightening Torque : 1.7-1.7 N.m
    • Total Lifecycle Carbon Footprint : 17 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • ITH Conventional Free Air Thermal Current : 10 A (at 60 °C)
    • Relationship Type : Compatible relationship
    • Add Ons : LAD4RCU
    • Pep Code : ENVPEP1501004EN
    • Pep Verification Date : 2025-08-05
    • PCR Version : PCR-4-ed4-EN-2021 09 06
    • PSR Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
    • Functional Unit Description : Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
    • Functional Unit Unit : unit
    • Product Kit Identifier : N
    • Product Manager : NANNAN YAN
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : -40-70 °C at Uc, -40-70 °C at Uc, -5-60 °C at 0.8...1.1 Uc, -5-60 °C at 0.8...1.1 Uc
    • EU ROHS Directive : Compliant By Exemption​, Compliant with Exemptions
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Mercury Free : Yes
    • Carbon Footprint : 16.594816101066108
    • Circularity Profile : ENVEOLI1501004
    • Environmental Disclosure : ENVPEP1501004EN
    • IP Degree Of Protection : IP2X conforming to VDE 0106
    • Operating Altitude : 9842.52 ft (3000 m) without derating
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1501004EN
    • Pep Verification Date : 2025-08-05
    • PCR Version : PCR-4-ed4-EN-2021 09 06
    • PSR Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Range Of Product : TeSys Deca control relay, TeSys Deca
    • Product Or Component Type : auxiliary contactor
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months