Reversing ultra compact starter, TeSys Hybrid, 3P, 500VAC, 0.75kW at 400V, 24VDC, Spring terminal

Compact Starter_Rev 2.4A STD S

SQDLZ2H2X43BD LZ2H2X43BD 3606485421063
337.99 / EA
http://schema.org/OutOfStock
  • Depth: 114.5 mm
TeSys H ultra compact reverse starter, 3 poles, 2.4A/500V AC-53, for control and protection of 3-phase motors up to 0.75kW@400V (1HP@480V). The hybrid technology used for power contacts procures ultra compactness (22.5mm width) as well as an extended electrical durability up to 30 million cycles AC-53. It provides control for 2 directions of rotation, an adjustable motor current 0.18-2.4A, class 10A thermal overload protection with auto/manual/remote reset, phase loss and phase unbalanced protection, stall and jam motor protection. To be supplied with 24V DC, it provides logic inputs for FW/RV motor direction and remote reset after thermal tripping, 1C/O contact relay for fault indication, LED status on front face for indication of tripping and motor running. DIN rail mounting, spring terminals for control and power, it can be used without derating for ambient temperatures from -25 to 70°C. Multi standards certified (IEC, UL, CCC).
QTY
  • Product Description
  • Features
  • Specifications
TeSys H ultra compact reverse starter, 3 poles, 2.4A/500V AC-53, for control and protection of 3-phase motors up to 0.75kW@400V (1HP@480V). The hybrid technology used for power contacts procures ultra compactness (22.5mm width) as well as an extended electrical durability up to 30 million cycles AC-53. It provides control for 2 directions of rotation, an adjustable motor current 0.18-2.4A, class 10A thermal overload protection with auto/manual/remote reset, phase loss and phase unbalanced protection, stall and jam motor protection. To be supplied with 24V DC, it provides logic inputs for FW/RV motor direction and remote reset after thermal tripping, 1C/O contact relay for fault indication, LED status on front face for indication of tripping and motor running. DIN rail mounting, spring terminals for control and power, it can be used without derating for ambient temperatures from -25 to 70°C. Multi standards certified (IEC, UL, CCC).
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Conformance Attributes
    • Certifications : CE, cULus
    • Standards : IEC 60947-4-2, UL 60947-4-1
  • Complementary Attributes
    • Maximum Horse Power Rating : 0.5 hp 200 V AC, 0.5 hp 230 V AC, 1 hp 460 V AC
    • Maximum Operating Rate : 120 cyc/mn AC-51 50 %, 6 cyc/mn AC-53A 50 %
    • Ie Rated Operational Current : 2.4 A 500 V AC-53A mounting side by side, 2.4 A 500 V AC-51, 2.4 A 500 V AC-53A, 2.4 A 500 V AC-51 mounting side by side
    • Control Circuit Voltage Limits : 19.2...30 V DC
    • Uc Control Circuit Voltage : 24 V DC
    • Ue Rated Operational Voltage : 500 V AC
    • Ui Rated Insulation Voltage : 500 V AC 50/60 Hz
    • Uimp Rated Impulse Withstand Voltage : 6 kV
  • Important Information Attributes
    • Current Consumption : <= 40 mA 24 V DC, <= 40 mA 24 V DC, <= 40 mA 24 V DC, <= 40 mA 24 V DC, <= 40 mA 24 V DC, <= 40 mA 24 V DC
    • Motor Power Kw : 0.37 kW 220 V AC 0.65, 0.37 kW 230 V AC 0.65, 0.75 kW 380 V AC 0.65, 0.75 kW 400 V AC 0.65, 0.75 kW 415 V AC 0.65, 0.75 kW 440 V AC 0.65, 1.1 kW 500 V AC 0.65
    • Reset : manual, automatic reset, electrical reset
    • Connections Terminals : spring clamp terminals 1 0.2-2.5 mm² rigid, spring clamp terminals 1 0.25-2.5 mm² flexible - with cable end, spring clamp terminals 1 0.2-2.5 mm² flexible - without cable end
    • Ie Rated Operational Current : 2.4 A 500 V AC-53A mounting side by side, 2.4 A 500 V AC-51, 2.4 A 500 V AC-53A, 2.4 A 500 V AC-51 mounting side by side
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-02-26
    • Global Commercial Status : Commercialised
    • Return Indicator : Y
    • Stocking Flag : N
    • Stock Policy : 2
    • Device Type : Relay, Control & Measurement - measuring, monitoring device
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : PPIBS
    • Average Life Duration : 15 year(s)
    • Weee Applicability : Finished product
    • Weee Scope : In
    • Legacy Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1509013EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant
    • Rohs Eur Conformity Date : 2025
    • Rohs Eur Full Compliance Status : Compliant
    • China Rohs In Scope : Yes
    • China Rohs Label : 1
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Product Kit Identifier : N
    • Device Short Name : LZ2H
    • Electrical Durability : 30 Mcycles
    • Energy Efficiency Optimized : False
    • Motor Starter Type : direct on line
    • Mounting Mode : by clips
    • Mounting Support : DIN rail
    • Poles Description : 3P
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Name : TeSys Hybrid
    • Product Or Component Type : reversing ultra-compact starter
    • Protective Treatment : TC
    • Range : TeSys
    • Returnability : Yes
    • Sustainable Packaging : No
    • Thermal Overload Class : class 10A IEC 60947-4-2
    • Thermal Protection Adjustment Range : 0.18-2.4 A
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Warranty In Months : 18
    • R Thermal Protection Adj Range : 0.18-2.4 A
    • Control Circuit Voltage 18 Control Circuit Voltage : 24 V
    • Control Circuit Voltage 18 Network Type : DC
    • Pep Code : ENVPEP1509013EN
    • Offer Owner Code : 190788
    • Height Nominal : 99 mm
    • Width Nominal : 22.5 mm
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : -25-70 °C without derating, -25-70 °C without derating, -25-70 °C without derating, -25-70 °C without derating
    • Take Back : Nej
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Ambient Air Temperature For Storage : -40-80 °C
    • Circularity Profile : ENVEOLI1509013EN
    • Environmental Disclosure : ENVPEP1509013EN
    • Eu Rohs Directive : Compliant
    • Ip Degree Of Protection : IP20
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1509013EN
  • General Attributes
    • Product Or Component Type : reversing ultra-compact starter
  • ETIM
    • ETIM 8 : EC001037
    • ETIM 9 : EC001037
  • Specifications
    • Depth : 114.5 mm