Regulated Power Supply, 100...240V AC, 48V, 10A, single phase, Optimized

REGULATED POWER SUPPLY, 100...

SQDABLS1A48100 ABLS1A48100 3606482185210
646.24 / EA
http://schema.org/OutOfStock
  • Country of Origin: India
  • Depth: 128.5 mm
  • Dielectric Strength: 1500 V, 2000 V, 3000 V
  • Enclosure Material: Metal
  • Height: 123.6 mm
  • Input Voltage: ...240 V, ...375 V
  • Net Weight: 1.25 kg
  • Output Voltage: 48 V
  • Weight: 1.25 kg
  • Width: 85.5 mm
QTY
  • Specifications
  • Complementary
    • Output Coupling : single/parallel by switch
    • Height : 123.6 mm
    • Residual Ripple : 200 mV
    • Status Led : 1 LED (Green) output voltage
    • Holding Time : > 20 ms 115 V AC || > 20 ms 230 V AC
    • Efficiency At Full Load : 85...264 V AC || 120...375 V DC
    • Earthing System : TN || TT || IT
    • Connections - Terminals : screw connection 0.5...4 mm², AWG 20...AWG 12) without wire end ferrule output || screw connection 0.5...2.5 mm², AWG 20...AWG 14) with wire end ferrule output || screw connection 0.75...4 mm², AWG 18...AWG 12) without wire end ferrule input || screw connection 0.75...4 mm², AWG 18...AWG 12) with wire end ferrule input
    • Dielectric Strength : 3000 V AC with input to output || 2000 V AC with input to ground || 1500 V AC with output to ground
    • Network Frequency Limits : 50-60 Hz
    • Marking : CE || UKCA
    • Current Consumption : < 5.4 A 115 V AC || < 2.7 A 230 V AC || < 5 A 140 V DC
    • Supply : SELV IEC 60950-1 || SELV IEC 60204-1 || SELV IEC 60364-4-41
    • Net Weight : 1.25 kg
    • Maximum Leakage Current : 1 mA 240 V AC
    • Input Protection Type : integrated fuse (not interchangeable) 10 A || external protection (recommended) 20 A || external protection (recommended) 16 A || external protection (recommended) 13 A
    • Output Protection Type : against overload and short-circuits, protection technology: automatic reset || against over temperature, protection technology: manual reset || against overvoltage, protection technology: manual reset
    • Service Life : 10 year(s) 40 °C 50 % load
    • Meantime Between Failure [Mtbf] : at 25 °C, full load conforming to SR 332
    • Power Dissipation In W : 45 W
    • Output Voltage Limits : 44…54 V
    • Mounting Support : top hat type TH35-15 rail IEC 60715 || top hat type TH35-7.5 rail IEC 60715 || double-profile DIN rail
    • Load Capacitance : 8000 µF
    • Response Time : < 1 s
    • Line And Load Regulation : < 1.5 % network 0 to 100 % load at 25 °C || < 0.5 % network full voltage range in line at 25 °C
    • Width : 85.5 mm
    • Overvoltage Category : II
    • Inrush Current : 45 A 115 V || 90 A 230 V
    • Efficiency : 85 % 115 V AC || 88 % 230 V AC
    • Depth : 128.5 mm
    • Power Factor : 0.95 at 115 V AC || 0.95 at 230 V AC
  • Specifications
    • Country of Origin : India
    • Width : 85.5 mm
    • Height : 123.6 mm
    • Weight : 1.25 kg
    • Range Of Product : Modicon Power Supply
    • Output Voltage : 48 V DC
    • Product Or Component Type : power supply
    • Power Supply Type : regulated switch mode
    • Input Voltage : 100...240 V AC single phase || 100...240 V AC phase to phase || 140...375 V DC
    • Power Supply Output Current : 10 A
    • Kw Rating : 240 W
    • Enclosure Material : metal
  • Environment
    • Standards : IEC 62368-1 || EN/IEC 61204-3 || IEC 61000-6-1 || IEC 61000-6-2 || IEC 61000-6-3 || IEC 61000-6-4 || IEC 61000-3-2 || EN 61000-3-3 || UL 62368-1 || CSA C22.2 No 62368-1 || CSA C22.2 No. 107.1
    • Ambient Air Temperature For Operation : 40-70 °C with current derating of 1.67 % per °C mounting position A 115 V AC < 6561.68 ft (2000 m) || 50-70 °C with current derating of 2.5 % per °C mounting position A 230 V AC < 6561.68 ft (2000 m)
    • Product Certifications : CE || cUL Listed || cUL Recognized || RCM || CB Scheme || EAC || KC || UKCA || cURus
    • Pollution Degree : 2
    • Electromagnetic Compatibility : immunity to electrostatic discharge - test level: 8 kV (contact discharge) conforming to IEC 61000-4-2 || immunity to electrostatic discharge - test level: 15 kV (air discharge) conforming to IEC 61000-4-2 || immunity to conducted RF disturbances - test level: 15 V/m (80 MHz...2 GHz) conforming to IEC 61000-4-3 || immunity to conducted RF disturbances - test level: 5 V/m (2...2.7 GHz) conforming to IEC 61000-4-3 || immunity to conducted RF disturbances - test level: 5 V/m (2.7...6 GHz) conforming to IEC 61000-4-3 || immunity to fast transients - test level: 4 kV (on input-output) conforming to IEC 61000-4-4 || surge immunity test - test level: 4 kV (between power supply and earth) conforming to IEC 61000-4-5 || surge immunity test - test level: 3 kV (between phases) conforming to IEC 61000-4-5 || immunity to conducted RF disturbances - test level: 15 V (0.15...80 MHz) conforming to IEC 61000-4-6 || immunity to magnetic fields - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8 || immunity to voltage dips conforming to IEC 61000-4-11 || disturbing field emission conforming to EN 55016-2-3 || limits for harmonic current emissions conforming to IEC 61000-3-2 || conforming to EN 55016-1-2 || conforming to EN 55016-2-1
    • Shock Resistance : 150 m/s² 11 ms
    • Vibration Resistance : 3 mm (f= 2-9 Hz) conforming to IEC 60068-2-6 || 10 m/s² (f= 9-200 Hz) conforming to IEC 60068-2-6
    • Ip Degree Of Protection : IP20
    • Operating Altitude : < 5000 m overvoltage category II
    • Electrical Shock Protection Class : class I
    • Electromagnetic Emission : conducted emissions IEC 61000-6-3 || radiated emissions IEC 61000-6-4
  • Environmental data
    • Packaging Made With Recycled Cardboard : No
    • Environmental Disclosure : ENVPEP2007005EN
    • Packaging Without Single Use Plastic : Yes
    • Scip Number : 698d9b2a-7a6a-4b8f-a149-489156f55645
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Minimum Percentage Of Recycled Plastic Content : 0
    • Circularity Profile : ENVEOLI2007005EN
    • Take-Back : No