REVERSING CONTACTOR

REVERSING CONTACTOR

SQDLC2D1156F7 LC2D1156F7 3389110533262
1404.28 / EA
http://schema.org/OutOfStock
  • Country of Origin: Czechia
  • Depth: 148 mm
  • Height: 158 mm
  • Net Weight: 6.35 kg
  • Warranty Length: 18 mth
  • Weight: 6.35 kg
  • Width: 266 mm
TeSys Deca reversing contactor, 3P(3NO) for category AC-3/3e applications up to 150A @440V. It provides with 110V 50/60H coil, with 1NO+1NC auxiliary contact, power and control connections by screw clamp terminals. It procures with 8 Mcycles mechanical durability and 0.95 Mcycles electrical durability. It provides IP20 protection on front face conforming to IEC 60529. It can cover -40°C to 60°C operation temperature and without derating under 3000m altitude. Designed for demanding applications with maximum operating rates up to 2400 cycles per hour under maximum 60°C. The dimension is 158mm x 266mm x 148mm (H x W x D), mounting on rail or plate. Multi standards certified(UL,LROS,CSA,CCC,EAC,UKCA,CB,DNV-GL,RINA,BV).
QTY
  • Product Description
  • Features
  • Specifications
TeSys Deca reversing contactor, 3P(3NO) for category AC-3/3e applications up to 150A @440V. It provides with 110V 50/60H coil, with 1NO+1NC auxiliary contact, power and control connections by screw clamp terminals. It procures with 8 Mcycles mechanical durability and 0.95 Mcycles electrical durability. It provides IP20 protection on front face conforming to IEC 60529. It can cover -40°C to 60°C operation temperature and without derating under 3000m altitude. Designed for demanding applications with maximum operating rates up to 2400 cycles per hour under maximum 60°C. The dimension is 158mm x 266mm x 148mm (H x W x D), mounting on rail or plate. Multi standards certified(UL,LROS,CSA,CCC,EAC,UKCA,CB,DNV-GL,RINA,BV).
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Environment
    • Mechanical Robustness : vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor closed15 Gn for 11 ms || shocks contactor open6 Gn for 11 ms
    • Ambient Air Temperature For Operation : -40-60 °C || 60-70 °C with derating
    • Height : 158 mm
    • Climatic Withstand : IACS E10
    • Pollution Degree : 3
    • Net Weight : 6.35 kg
    • Flame Retardance : V1 conforming to UL 94
    • Ambient Air Temperature For Storage : -60-80 °C
    • Protective Treatment : TH IEC 60068-2-30
    • Ip Degree Of Protection : IP20 front face IEC 60529
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Width : 266 mm
    • Depth : 148 mm
  • Contractual warranty
    • Warranty : 18 months
  • Environmental data
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP060301EN
    • Packaging Without Single Use Plastic : No
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Scip Number : a530c666-91dd-4119-8d61-f1c22a361ecb
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
    • Circularity Profile : ENVEOLI100405EN
    • Take-Back : No
    • Carbon Footprint Of The Use Phase [B2, B3, B4, B6] : 163.00264388489205
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 60.178417734082934
    • Carbon Footprint Of The Distribution Phase [A4] : 2 kg CO2 eq.
    • Pvc Free : Yes
    • Carbon Footprint Of The Installation Phase [A5] : 0.7 kg CO2 eq.
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 237 kg CO2 eq.
    • Eu Rohs Directive : Compliant with Exemptions
    • Carbon Footprint Of The End-Of-Life Phase [C1 To C4] : 11.24154728284199
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 237.00410156700937
  • Complementary
    • Non-Overlap Time : 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
    • Minimum Switching Current : 5 mA for signalling circuit
    • Control Circuit Voltage Limits : 0.3...0.5 Uc (55-55 °C):drop-out AC 50/60 Hz || 0.8...1.15 Uc (55-55 °C):operational AC 50/60 Hz
    • Insulation Resistance : > 10 MOhm for signalling circuit
    • Inrush Power In Va : 280-350 VA 60 Hz 0.8 20 °C) || 280-350 VA 50 Hz 0.8 20 °C)
    • Coil Technology : built-in bidirectional peak limiting diode suppressor
    • Minimum Switching Voltage : 17 V for signalling circuit
    • Signalling Circuit Frequency : 25...400 Hz
    • Heat Dissipation : 3-8 W 50/60 Hz
    • Auxiliary Contacts Type : mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
    • Hold-In Power Consumption In Va : 2-18 VA 20 °C) 0.3 60 Hz || 2-18 VA 20 °C) 0.3 50 Hz
  • Specifications
    • Country of Origin : Czechia
    • Width : 266 mm
    • Height : 158 mm
    • Weight : 6.35 kg
    • Interlocking Type : mechanical || electrical
    • [Uc] Control Circuit Voltage : 110 V AC 50/60 Hz
    • [Ue] Rated Operational Voltage : power circuit <= 1000 V AC 25...400 Hz || power circuit <= 300 V DC
    • Power Dissipation Per Pole : 24 W AC-1 || 7.9 W AC-3
    • Average Impedance : 0.6 mOhm - Ith 200 A 50 Hz for power circuit
    • Auxiliary Contact Composition : 1 NO + 1 NC
    • [Ith] Conventional Free Air Thermal Current : 200 A (at 60 °C) for power circuit
    • Mounting Support : plate || rail
    • Control Circuit Type : AC 50/60 Hz
    • Standards : CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Contactor Application : motor control || resistive load
    • Rated Breaking Capacity : 1100 A at 440 V for power circuit conforming to IEC 60947
    • Product Or Component Type : reversing contactor
    • Product Certifications : BV || CCC || CSA || DNV || GL || RINA || UL || EAC || UKCA
    • Irms Rated Making Capacity : 140 A AC for signalling circuit conforming to IEC 60947-5-1 || 250 A DC for signalling circuit conforming to IEC 60947-5-1 || 1260 A at 440 V for power circuit conforming to IEC 60947
    • Product Name : TeSys Deca
    • Associated Fuse Rating : 10 A gG for signalling circuit conforming to IEC 60947-5-1 || 250 A gG at <= 690 V coordination type 1 for power circuit || 200 A gG at <= 690 V coordination type 2 for power circuit
    • [Uimp] Rated Impulse Withstand Voltage : 8 kV IEC 60947
    • Connections - Terminals : control circuit lugs-ring terminals 8 mm) || power circuit lugs-ring terminals 25 mm) || power circuit bars 1 5 x 25 mm
    • Range : TeSys
    • Pole Contact Composition : 3 NO
    • Device Presentation : preassembled with reversing power busbar
    • Utilisation Category : AC-1 || AC-3
    • [Ie] Rated Operational Current : 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit || 115 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
    • Operating Time : 20...50 ms closing || 6...20 ms opening
    • Maximum Operating Rate : 2400 cyc/h 60 °C
    • Electrical Durability : 0.8 Mcycles 200 A AC-1 <= 440 V || 0.95 Mcycles 115 A AC-3 <= 440 V
    • Tightening Torque : control circuit 1.2 N.m lugs-ring terminals flat Ø 6 mm M3.5 || control circuit 1.2 N.m lugs-ring terminals Philips No 2 M3.5 || power circuit 12 N.m lugs-ring terminals hexagonal 13 mm M8 || power circuit 12 N.m bars hexagonal 13 mm M8 || control circuit 1.2 N.m lugs-ring terminals pozidriv No 2 M3.5
    • Poles Description : 3P
    • Overvoltage Category : III
    • Motor Power Kw : 30 kW at 220...230 V AC 50-60 Hz || 55 kW at 380...400 V AC 50-60 Hz || 59 kW at 415 V AC 50-60 Hz || 59 kW at 440 V AC 50-60 Hz || 75 kW at 500 V AC 50-60 Hz || 80 kW at 660...690 V AC 50-60 Hz || 65 kW at 1000 V AC 50-60 Hz
    • Maximum Horse Power Rating : 30 hp at 200/208 V AC 60 Hz for 3 phase motors || 40 hp at 230/240 V AC 60 Hz for 3 phase motors || 75 hp at 460/480 V AC 60 Hz for 3 phase motors || 100 hp at 575/600 V AC 60 Hz for 3 phase motors
    • [Ui] Rated Insulation Voltage : power circuit 600 V CSA || power circuit 600 V UL || signalling circuit 690 V IEC 60947-1 || signalling circuit 600 V CSA || signalling circuit 600 V UL || power circuit 1000 V IEC 60947-4-1
    • Mechanical Durability : 8000000 cycles
    • Device Short Name : LC2D
    • [Icw] Rated Short-Time Withstand Current : 250 A 40 °C - 10 min for power circuit || 550 A 40 °C - 1 min for power circuit || 950 A 40 °C - 10 s for power circuit || 1100 A 40 °C - 1 s for power circuit || 100 A - 1 s for signalling circuit || 120 A - 500 ms for signalling circuit || 140 A - 100 ms for signalling circuit
    • Protective Cover : with