Schneider Electric at Mayer

Automatic switch, PowerPact L, 600A, 3 pole, 600VAC, 50kA, lugs, magnetic

AUTOMATIC MOLDED CASE SWITCH 6

SQDLLM36000S60X LLM36000S60X 785901678564
7378.29 / EA
http://schema.org/OutOfStock
  • Country of Origin: USA
  • Depth: 6.61 in
PowerPacT L-Frame automatic switches are a disconnect device and can be used to open and close a circuit under normal operating conditions. The automatic switches are similar in construction, use the same accessories, and offer the same connection possibilities as the L-Frame circuit breaker version. The switches have a factory set, nonadjustable trip point calibrated to protect the molded case switch. The automatic switch can make and break its rated current. PowerPacT L-Frame switches are available in unit mount, I-Line, plug in, or drawout constructions. This switch has lugs on the line side and terminal nuts on the load side. This PowerPacT L, 600A, 3 pole, automatic switch has a short circuit withstand current rating of 50kA at 600VAC. PowerPacT L automatic switches comply to UL, CSA, ANCE, and IEC standards.
QTY
  • Product Description
  • Features
  • Specifications
PowerPacT L-Frame automatic switches are a disconnect device and can be used to open and close a circuit under normal operating conditions. The automatic switches are similar in construction, use the same accessories, and offer the same connection possibilities as the L-Frame circuit breaker version. The switches have a factory set, nonadjustable trip point calibrated to protect the molded case switch. The automatic switch can make and break its rated current. PowerPacT L-Frame switches are available in unit mount, I-Line, plug in, or drawout constructions. This switch has lugs on the line side and terminal nuts on the load side. This PowerPacT L, 600A, 3 pole, automatic switch has a short circuit withstand current rating of 50kA at 600VAC. PowerPacT L automatic switches comply to UL, CSA, ANCE, and IEC standards.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • Line Rated Current : 600 A
  • Important Information Attributes
    • Persona Type Ids : LC, OM, OM8, PB
    • Persona Type Names : Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Electrical Connection : lugs, line, terminal nut, load
    • Certificate Agency : UL Listed, NMX, IEC, CCC, CE, CSA
    • Short-circuit Withstand : 125 kA 240 V UL 489, 100 kA 480 V UL 489, 50 kA 600 V UL 489
    • Carbon Footprint Of The Distribution Phase [A4] : 1.966271580566898, 2 kg CO2 eq.
    • Carbon Footprint Of The End-of-life Phase [C1 To C4] : 10 kg CO2 eq., 10.302971150240523
    • Carbon Footprint Of The Installation Phase [A5] : 1.8967904693791804, 2 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 44 kg CO2 eq., 43.82880551360121
    • Carbon Footprint Of The Use Phase [B2, B3, B4, B6] : 1 102 kg CO2 eq., 1102.0746377830335
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-01-15
    • Return Indicator : Y
    • Stocking Flag : Y
    • Stock Policy : 2
    • Device Type : LV equipment - LV switch - disconnector
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : PPIBS
    • Average Life Duration : 15 year(s)
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2206029_V2
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 2543
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : No
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Awg Gauge : 2 x 2/0 AWG...500 kcmil ( aluminium/copper )
    • Circuit Breaker Type : L-Frame
    • Energy Efficiency Optimized : False
    • Magnetic Tripping Current : 4800-4800 A
    • Mounting Mode : unit mount
    • Number Of Poles : 3P
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : automatic switch
    • Range Of Product : PowerPact L
    • Returnability : Yes
    • Software Version : v6.2.5-6
    • Sustainable Packaging : No
    • Terminal Identifier : AL600LS52K3
    • Tightening Torque : 50-50 N.m 70-240 mm² (2/0 AWG...500 kcmil)
    • Total Lifecycle Carbon Footprint : 1 160 kg CO2 eq.
    • Trip Unit Technology : magnetic
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Pep Code : ENVPEP2206029EN
    • Database Version : 2024-01
    • Pep Verification Date : 2025-08-21
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
    • Data Source : extrapolated product
    • Functional-unit Description : Protect the installation from overloads and short circuits in a circuit with rated voltage Ue, rated current In, with Np poles, a rated breaking capacity Icu, and, if applicable, the specific specifications, in the Industrial application area, according to the appropriate use scenario, and during the reference service life of the product of 20 years.
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unit
    • Reference Lifetime, In Y : 20
    • Energy Model - Manufacturing [A1-a3] : Electricity Mix; Low voltage; 2020; United States, US
    • Energy Model - Installation [A5] : No energy used
    • Energy Model - Use [B6] : Electricity Mix; Low voltage; 2020; United States, US
    • Energy Model - End Of Life [C1-c4] : Global, European and French datasets are used.
    • Recyclability Potential, In % : 58
    • Height Nominal : 13.38 in
    • Width Nominal : 5.51 in
    • [Ue] Rated Operational Voltage : 600 V AC
    • Nbr. Of Units In Pkg. : 1
    • Package Weight(Lbs) : 6.804 kg
    • Take-back : No
    • Warranty (In Months) : 18
    • Customs Code : 8536509040
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • Mercury Free : Yes
    • Carbon Footprint : 1160.0694764968212
    • Circularity Profile : ENVEOLI2206029_V2
    • Environmental Disclosure : ENVPEP2206029EN
    • Eu Rohs Directive : Compliant By Exemption
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2206029EN
    • Pep Verification Date : 2025-08-21
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : automatic switch
    • Range Of Product : PowerPact L
  • Specifications
    • Country of Origin : United States
    • Depth : 6.61 in