Schneider Electric at Mayer

PowerLogic P3M30 3CT 2Io ringlug 4VT 6DI 14DO 2Arc 110-230V DI110V RS485 RJ45 RS232 ANSI

POWERLOGIC P3M30 3CT 2IO RINGL

SQDREL53151 REL53151 3606487107002
7616.49 / EA
http://schema.org/OutOfStock
  • Depth: 230 mm
  • Height: 6.93 in
  • Number of Outputs: 11 DO1 Watchdog
  • Warranty Length: 10 yr, 2 yr
  • Width: 10.63 in
Perfectly suited for buildings and industry, utilities, and large industrial motor protection systems. The relay include protection for overcurrent, overload, broken conductor, earth-fault and breaker failure as per ANSI. It also feature typical medium sized motor protection schemes. Simple, reliable, safe and easy-to-use, thanks to the User Interface display. The protection relay can to be supplied by a 48 VAC/VDC to 230 VAC/VDC network. It include 6 digital inputs, 14 digital outputs, 1 RS485, 1 RJ45 and 1 RS232 communication port and 1 USB on front of the device. Mechanical dimensions are 176 mm in height, 270 mm in width and 230 mm in depth. The relays are certified with EN 60255-26 for electromagnetic compatiblity.
QTY
  • Product Description
  • Specifications
Perfectly suited for buildings and industry, utilities, and large industrial motor protection systems. The relay include protection for overcurrent, overload, broken conductor, earth-fault and breaker failure as per ANSI. It also feature typical medium sized motor protection schemes. Simple, reliable, safe and easy-to-use, thanks to the User Interface display. The protection relay can to be supplied by a 48 VAC/VDC to 230 VAC/VDC network. It include 6 digital inputs, 14 digital outputs, 1 RS485, 1 RJ45 and 1 RS232 communication port and 1 USB on front of the device. Mechanical dimensions are 176 mm in height, 270 mm in width and 230 mm in depth. The relays are certified with EN 60255-26 for electromagnetic compatiblity.
  • Communications & Management Attributes
    • Communication Port Protocol : IEC 61850 ed. 1, IEC 61850 ed. 2, IEC 60870-5-101, TCP, Modbus TCP, EtherNet/IP, IEC 60870-5-103, DNP3, Modbus RTU, DeviceNet, SPAbus
  • Physical Attributes
    • Mounting Case Size : 30TE
  • Complementary Attributes
    • Integrated Connection Type : front USB port 1rear RS485 1, rear RJ45 1
  • Important Information Attributes
    • Control Type : switchgear control and monitoring, programmable switchgear interlockinglocal control on single-line diagram, local control with I/O keys, local/remote control, 2 function keysmobile application with Easergy SmartApp, web-server, programmable logic
    • Cybersecurity : password protection, port hardening
    • Display Type : LCD 128 x 128 pixels with single line diagram, LCD 128 x 128 pixels with ANSI symbols
    • Electromagnetic Compatibility : emission tests IEC/EN 60255-26 ed. 3, emission tests CISPR 11, emission tests CISPR 22, EMC immunity IEC/EN 60255-26 ed. 3, EMC immunity EN/IEC 61000-4-18EMC immunity level 4 EN/IEC 61000-4-2EMC immunity level 3 EN/IEC 61000-4-3, EMC immunity level 4 EN/IEC 61000-4-4, EMC immunity level 3 EN/IEC 61000-4-5, EMC immunity level 3 EN/IEC 61000-4-6, EMC immunity EN/IEC 61000-4-8EMC immunity level 5 EN/IEC 61000-4-9, EMC immunity EN/IEC 61000-4-29, EMC immunity EN/IEC 61000-4-11, EMC immunity EN/IEC 61000-4-17, EMC immunity IEC 60255-22-1, EMC immunity IEC 60255-22-2, EMC immunity IEC 60255-22-3, EMC immunity IEC 60255-22-4, EMC immunity IEC 60255-22-5, EMC immunity IEC 60255-22-6, EMC immunity IEC 60255-27EMC immunity class III IEC 60255-5, EMC immunity EN/IEC 60255-1
    • Environmental Characteristic : exposure to dry heat Bb EN/IEC 60068-2-2, exposure to cold Ad EN/IEC 60068-2-1, exposure to damp heat in service Db EN/IEC 60068-2-30exposure to damp heat in service Cab EN/IEC 60068-2-78
    • Mechanical Robustness : vibrations class II) IEC 60255-21-1vibrationsFc IEC 60068-2-6shocks class II) IEC 60255-21-2shocksEa IEC 60068-2-27, seismic tests method A class II) IEC 60255-21-3
    • Monitoring Function : trip circuit supervision 74, circuit breaker monitoring, relay self-monitoring
    • Network And Machine Diagnosis Type : event recording, disturbance recording, tripping context
    • Number Of Sensors : 0 temperature sensor(s), 0 arc sensor(s)
    • Protection Type : switch ON to fault (SOTF) 25, synchro-check 25undervoltage 27directional active underpower 32, phase undercurrent 37 8-8negative sequence overcurrent 46, phase sequence 46excessive starting time, locked rotor 48/51LRthermal overload protection 49earth fault overcurrent 50N/51Nphase overcurrent 50/51breaker failure 50BF, switch ON to fault (SOTF) 27capacitor bank unbalance 51Ccapacitor overvoltage 59Covervoltage 59earth fault overvoltage 59Nstator earth fault 64Smotor restart inhibition 66programmable stages 99 8-8, programmable curve 64S, cold load pick-up 66CT supervision 60 8-8VT supervision 60FL
    • Software Name : eSetup Easergy Pro virtual simulation test, Easergy SmartApp
    • Switchgear Diagnosis Type : CT supervision TCS, trip circuit supervision TCS
    • Type Of Measurement : voltage zero sequencevoltage positive sequencevoltage negative sequencevoltage ratio of negative and positive, fault location, positive sequence, current phasor diagram viewvoltage 2nd, 15th harmonics with THDRMS active power negative sequencereactive power ratio of negative and positivecondition monitoring CB wear 2nd, 15th harmonics with THD, current 3-phase, current zero sequence, current positive sequence, current negative sequence, current ratio of negative and positivevoltage phase to earth, voltage phase to phase, short circuit fault reactance 3-phase, fault location current phase to phase, earth fault reactance, frequency zero sequence, active power positive sequence, RMS active power ratio of negative and positive, reactive power phase to earth, RMS reactive power negative sequence, apparent power, RMS apparent power, active energy, reactive energy, cos φ, tan φ, power angle, power factor, voltage phasor diagram view, current 2nd, 15th harmonics with THD, condition monitoring CB wear phasor diagram view, voltage interruption 2nd, 15th harmonics with THD
    • Connections - Terminals : screw removable (digital input/output)pin removable (voltage transformer), ring lugs fixed (current transformer)
    • Carbon Footprint Of The Distribution Phase [A4] : 4.81196451758779, 5 kg CO2 eq.
    • Carbon Footprint Of The End-of-life Phase [C1 To C4] : 11 kg CO2 eq., 11.244770232756933
    • Carbon Footprint Of The Installation Phase [A5] : 0.17582600775273327, 0.2 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 167 kg CO2 eq., 167.06215675529174
    • Carbon Footprint Of The Use Phase [B2, B3, B4, B6] : 1 056 kg CO2 eq., 1056.3500660970483
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-10
    • Return Indicator : N
    • Stocking Flag : Y
    • Stock Policy : 2
    • Device Type : Relay, Control & Measurement - Protection relay
    • Serviceability : Yes
    • Traceability : Yes
    • Field Service Division : DPIBS
    • Average Life Duration : 15 year(s)
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1706005_V2
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 2413
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • China Rohs Label : 5
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Product Kit Identifier : N
    • Arc Flash Protection : yes
    • Device Short Name : P3M30-CBGAD-KA1FA-BBAAB
    • Local Signalling : 2 LEDs16 LEDs programmable
    • Mounting Mode : flush mounting
    • Number Of Key : 2 customizable
    • Operating Threshold : 110...230 V AC/DC
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : protection relay
    • Protective Treatment : conformal coating
    • Range Of Product : PowerLogic P3
    • Relay Application : motor
    • Relay Type : differential current relay
    • Returnability : No
    • Setting : 4
    • Single Line Diagram : 3 controlled + 3 displayed
    • Software Version : v6.3.0.1-4
    • Sustainable Packaging : No
    • Time Synchronisation Protocol : SNTP
    • Total Lifecycle Carbon Footprint : 1 240 kg CO2 eq.
    • Web Server : embedded HTTP server
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Pep Code : ENVPEP1706005EN
    • Database Version : 2024-01
    • Pep Verification Date : 2025-09-30
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
    • Data Source : extrapolated product
    • Functional-unit Description : Other switchgear and controlgear solutions mentioned in the scope (e.g. fuses TC32, all-or-nothing relays TC94, Measuring relays and protection equipment TC95), apply the general rules of PCR and mention in the accompanying report the functional unit, the reference product characteristics, the reference lifetime and the use scenario which are applied consistently with the relevant IEC technical standards.Protect distribution networks and high voltage equipment like feeder, transformer, motor and generator against faults, (short circuit, over load …) 24h per day, for 10 years of continuous operations.
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unit
    • Reference Lifetime, In Y : 10
    • Energy Model - Manufacturing [A1-a3] : Electricity Mix; Low voltage; 2020; Latvia, LV
    • Energy Model - Installation [A5] : No energy used
    • Energy Model - Use [B6] : Electricity Mix; Low voltage; 2020; Asia Pacific, APAC
    • Energy Model - End Of Life [C1-c4] : Global, European and French datasets are used.
    • Recyclability Potential, In % : 37
    • Height Nominal : 176 mm
    • Height Useful : 176 mm
    • Width Nominal : 270 mm
    • Width Real : 270 mm
    • [Us] Rated Supply Voltage : 48...230 V AC/DC
    • Nbr. Of Units In Pkg. : 1
    • Package Weight(Lbs) : 5.3 kg
    • Take-back : No
    • Warranty (In Months) : 24
    • Customs Code : 8537109170
  • Environment Attributes Main
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 1239.6447836104376
    • Ambient Air Temperature For Operation : -40-65 °C-40-65 °C
    • Ambient Air Temperature For Storage : -40-70 °C-40-70 °C
    • Circularity Profile : ENVEOLI1706005_V2
    • Environmental Disclosure : ENVPEP1706005EN
    • Eu Rohs Directive : Compliant By Exemption
    • Ip Degree Of Protection : IP54 front IEC 60529
    • Operating Altitude : 6561.68 ft (2000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Relative Humidity : 0-95 %, without condensation
    • Pep Code : ENVPEP1706005EN
    • Pep Verification Date : 2025-09-30
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : protection relay
    • Range Of Product : PowerLogic P3
  • Output Attributes
    • Analogue Output Number : 0
    • Number Of Outputs : 11 DO1 watchdog
  • Contractual Warranty Attributes
    • Warranty Period : up to 10 years (Standard warranty 2 years. Please check with your local SE representative for extended warranty availability and conditions)
    • Warranty : up to 10 years (Standard warranty 2 years. Please check with your local SE representative for extended warranty availability and conditions)
  • Input Attributes
    • Input Type : 3 1/5 A CT phase current, 1 5/1 A CT residual current, 1 1/0.2 A CT residual current, 4 100 V/110 V VT voltage
    • Analogue Input Number : 0
    • Digital Input Number : 6
  • Specifications
    • Country of Origin : France, Latvia, United States
    • Height : 6.93 in
    • Width : 10.63 in
    • Depth : 230 mm