Schneider Electric at Mayer

PowerLogic EM3500 DIN rail meter - Modbus 4 quadrant - current transformer

EM3500, 4 QUAD, LOGGING, MODB

SQDMETSEEM3555 METSEEM3555 785901488514
1373.80 / EA
http://schema.org/OutOfStock
  • Certifications: CE IEC 61010, CULus UL 508
  • Depth: 59 mm
  • Height: 91 mm
  • Mounting Type: Screws
  • Number of Outputs: 1
  • Standard: CSA C22.2 No 14-05, IEC 61010-1, UL 508
  • Storage Temperature: -40-85 °C
  • Voltage: 90-347 V
  • Width: 107 mm
The EM3500 series offer a three-phases DIN rail-mounted energy meters fitted for accurate cost allocation and sub-metering. EM35xx models are designed for use with Low Votage Current Transducers 1/3Volt or 1Volt output. Current input from 5A to 32000A, according to the LVCT configuration in the HMI, ANSI C12.20 0.2% accuracy, IEC 62053-22 class 0.2S. The data logging capability protects data in the event of a power failure. Modbus, pulse output, and phase alarms are all provided to suit a wide variety of applications. This model add a bi-directional monitoring feature designed expressly for renewable energy applications. Suitable for a 230V AC network, with a supply voltage range of 90V AC to 300V AC at 50Hz or 60Hz. Compliant with UL508, CSA 22.2 number 14-05 and EN 61010-1. Product dimensions are as follows: width 107 mm, depth 59 mm, height 91 mm.
QTY
  • Product Description
  • Specifications
The EM3500 series offer a three-phases DIN rail-mounted energy meters fitted for accurate cost allocation and sub-metering. EM35xx models are designed for use with Low Votage Current Transducers 1/3Volt or 1Volt output. Current input from 5A to 32000A, according to the LVCT configuration in the HMI, ANSI C12.20 0.2% accuracy, IEC 62053-22 class 0.2S. The data logging capability protects data in the event of a power failure. Modbus, pulse output, and phase alarms are all provided to suit a wide variety of applications. This model add a bi-directional monitoring feature designed expressly for renewable energy applications. Suitable for a 230V AC network, with a supply voltage range of 90V AC to 300V AC at 50Hz or 60Hz. Compliant with UL508, CSA 22.2 number 14-05 and EN 61010-1. Product dimensions are as follows: width 107 mm, depth 59 mm, height 91 mm.
  • Complementary
    • Network Frequency : 60 Hz || 50 Hz
    • Communication Port Support : screw terminal block RS485
    • [Ue] Rated Operational Voltage : 90...347 V AC 50/60 Hz between phase and neutral UL || 156...600 V AC 50/60 Hz between phases UL || 90...300 V AC 50/60 Hz between phase and neutral CE || 125...300 V DC
    • Standards : CSA C22.2 No 14-05 || UL 508 || IEC 61010-1
    • Number Of Outputs : 1 alarm output || 1 pulse
    • Mounting Support : DIN rail
    • Power Consumption In Va : 5-5 VA 347 V AC between phase and neutral) || 5-5 VA 600 V AC between phases)
    • Product Certifications : CE IEC 61010 || cULus UL 508
    • Type Of Measurement : active and reactive power total || active and reactive power per phase || apparent power total || apparent power per phase || power factor total || power factor per phase || peak demand power || current || voltage || frequency
    • Communication Port Protocol : Modbus RTU 1200…38400 bps - 2-wire
    • Communication Service : total cumulated active energy || total cumulated energy
    • Ride-Through Time : 100 ms 120 V AC
    • Display Digits : 5
    • Communication Of Data : instantaneous and demand values || lifetime energy production
    • Tamperproof Of Settings : protected by access code
    • Measurement Current : 5-32000 A
    • Information Displayed : status and alert || communication with system || input/output status || error || Tx activity || Rx activity || instant power per usage
    • Function Available : external synchronisation to communication || fixed or rolling block
    • Mounting Mode : clip-on || by screws
    • Local Signalling : Red LED threshold reached || Green flashing LED output signal
    • Power Consumption In W : 3 W 300-300 V
    • Measurement Accuracy : power +/- 0.2 % || energy +/- 0.2 %
    • Technology Type : electronic
    • Buffer Size : 16-bit 10
    • Poles Description : 3P + N
    • Data Recording : energy consumption logs || time stamping
    • Analogue Input Type : split core current transducer 0.333 V or 1 V
    • Display Type : Backlit LCD
    • Device Application : partial meter || sub billing
    • Accuracy Class : class 0.2S power IEC 62053-22 || class 0.2S energy IEC 62053-22 || class 0.2S power ANSI C12.20 || class 0.2S energy ANSI C12.20
    • Rated Voltage : 90-347 V
  • Environment
    • Ambient Air Temperature For Operation : -30-70 °C
    • Height : 91 mm
    • 9 Mm Pitches : 12
    • Color : dark grey
    • Ambient Air Temperature For Storage : -40-85 °C
    • Relative Humidity : 0-95 %
    • Width : 107 mm
    • Depth : 59 mm
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • China Rohs Regulation : X
    • Eu Rohs Directive : Compliant with Exemptions
  • Specifications
    • Product Or Component Type : energy meter
    • Product Name : PowerLogic EM3500
    • Range : PowerLogic
    • Device Short Name : EM3555
    • Metering Type : peak demand power PM, QM, SM || current I1, I2, I3, Iavg || active, reactive, apparent energy (signed, four quadrant) || demand power P, Q, S || voltage U21, U32, U13, V1, V2, V3