VarPlus logic is a simple and efficient Power Controller for a automatic power factor correction equipment to maintain the power factor. It is a simple and intelligent relay which measures,monitor and Controls the reactive energy. It comes with Easy Commisioning , Step Size detection and monitoring along with the variour alarms. VPL12 can be used for 12 steps in a PFC equippment.
QTY
  • Product Description
  • Specifications
VarPlus logic is a simple and efficient Power Controller for a automatic power factor correction equipment to maintain the power factor. It is a simple and intelligent relay which measures,monitor and Controls the reactive energy. It comes with Easy Commisioning , Step Size detection and monitoring along with the variour alarms. VPL12 can be used for 12 steps in a PFC equippment.
  • Communications & Management Attributes
    • Type Of Alarms : step power loss < 75 %)message and alarm contact + step blocked, step faultymessage and alarm contact + step blocked, high current > 6 A CT)message and alarm contact, hunting (unstable regulation)message and alarm contact + step blocked, low current < 15 mA CT)message and alarm contact, overcompensationmessage and alarm contact, capacitor current overload (Irms/I1) > 130 % I1)message and alarm contact + step switched off, Over Temperature 50 °C)message and alarm contact + step switched off, Over Temperature 30 °C)fan switch, Over Voltage +/- 10 %)message and alarm contact + control stopped, total harmonic distortion > 7 %)message and alarm contact + step switched off
  • Physical Attributes
    • Color Code : front dark grey RAL 7016
    • Display Size : 56 x 25 mm
  • Complementary Attributes
    • US Rated Supply Voltage : 90...550 V AC, <= 999 kV AC with external VT, <= 999 kV AC with external VT, <= 999 kV AC with external VT
  • Important Information Attributes
    • Persona Type Ids : LC, OM, OM8, PB, SI
    • Persona Type Names : Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Measurement Accuracy : voltage +/- 1 %, current +/- 1 %, frequency +/- 1 %, energy (P,Q,S) +/- 2 %, cos φ +/- 2 %, total voltage harmonic distortion THD (U) +/- 2 %, individual voltage harmonic +/- 3 %, Temperature +/- 3 °C
    • Metering Type : power factor and displacement PF (signed, four quadrant), total current harmonic distortion THD (I), power factor average over lifetime, temperature maximum, phase current I1, I2, I3 RMS on load, active power P, P1, P2, P3 on load, reactive power Q, Q1, Q2, Q3 on load, apparent power S, S1, S2, S3 on load, voltage U21, U32, U13, V1, V2, V3 on load
    • Settings Operating Mode : automatic, manual
    • Time Delay Range : 1...6500 s on reconnection), 1...6500 s on response)
    • Type Of Setting : choice of stepping programs auto, choice of stepping programs LIFO, choice of stepping programs linear, delay between 2 successive switch on the same step 5...1200 s, step configuration programming auto, step configuration programming off, step configuration programming fixed, target cos phi 0.7 inductive...0.7 capacitive, target cos phi dual cos φ
    • Carbon Footprint Of The Distribution Phase A4 : 0.23061, 0.2 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 1 kg CO2 eq., 1.01
    • Carbon Footprint Of The Installation Phase A5 : 0.34502, 0.3 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 82 kg CO2 eq., 81.613
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 155 kg CO2 eq., 154.82
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-24
    • Device Type : Relay, Control & Measurement - measuring, monitoring device
    • Serviceability : Yes
    • Traceability : Yes
    • Field Service Division : DPIBS
    • Average Life Duration : 15 year(s)
    • Spare Used In Spare Kit : No
    • Spare Part Order Method : ERP to ERP
    • Spare Part Order Method Direction : Consult local ERP Setup
    • Service Catalog Item : Spare part
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1509016_V1
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status Id : COMPLIANT_WITH_EXEMPTIONS
    • China ROHS In Scope : Yes
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • WD Status : 1 - GSC certified
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Color Code : front dark grey RAL 7016
    • Compatibility Code : VPL 12
    • Data Recording : 5 alarms
    • Device Connection : communication Modbus RS485
    • Device Short Name : VPL12
    • Energy Efficiency Optimized : False
    • Measurement Voltage : 90-550 V AC 50/60 Hz
    • Mechanical Durability : 65000 cycles without maintenance
    • Mounting Support : panel 1-3 mm
    • Package Weight Lbs : 727.000 g
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : power factor controller
    • Range : PowerLogic
    • Returnability : Yes
    • Service Life In Hours : 100000 h without maintenance
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 238 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Pep Code : ENVPEP1509016EN
    • Pep Verification Date : 2023-05-01
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Functional Unit Description : Power factor controllers manages reactive energy and provide accurate measurements with an intelligent relay function to ensure maximum efficiency during 10 years.& 10& 10In addition. it adheres to LV and environmental standards. such as IEC 61010-1. IEC 61000 6-2. IEC 61000 6-4. IEC 61326-1 and UL 61010
    • Functional Unit Unit : unité (unit)
    • Product Kit Identifier : N
    • Product Manager : GNANAPRAKASHAM ELUMALAI
  • Environment Attributes Main
    • EU ROHS Directive : Compliant By Exemption​, Compliant with Exemptions
    • IP Degree Of Protection : front face IP41, rear face IP20
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 238.018629999999
    • Circularity Profile : ENVEOLI1509016_V1
    • Environmental Disclosure : ENVPEP1509016EN
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1509016EN
    • Pep Verification Date : 2023-05-01
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : power factor controller
  • Output Attributes
    • Output Type : control relay 0.2 A 110 V DC, control relay 1 A 48 V DC, control relay 2 A 400 V AC 50/60 Hz, control relay 1 A 24 V DC, control relay 5 A 250 V AC 50/60 Hz, control relay 5 A 120 V AC 50/60 Hz, fan 5 A 250 V AC 50/60 Hz, fan 1 A 48 V DC, alarm relay 5 A 250 V AC 50/60 Hz, alarm relay 1 A 48 V DC
    • Number Of Step Output Contacts : 12
  • Input Attributes
    • Input Function : switch 1 x dry contact