Terminal block, Linergy TR, push-in type, feed through, 2 level, 4 points, 2.5mm², blue, set of 50

Push-in terminal 2Level 4pts

SQDNSYTRP24DBL NSYTRP24DBL 3606480533242
6.64 / EA
http://schema.org/OutOfStock
  • Dielectric Strength: 1000 V
Linergy TR is terminal block for Linergy. It belongs to linergy passthrough terminal block with 2.5 mm² nominal cross section. The rated operational voltage is 600V conforming to CSA/UL and 500V conforming to EN/IEC 60947-7-1. The rated current is 22A conforming to EN/IEC 60947-7-1 and 20A conforming to CSA and UL. It has blue surface treatment Mounting by clip-on and top connection by double-level 2x2 push-in terminals. It could be connection without tool and disconnection by flat screwdriver. It is compatible with spacial enclosures for PrismaSeT G, PrismaSeT P, PrismaSeT HD, PrismaSeT Pack 250, PanelSeT, Mureva Enclosure, PrismaSeT XS, Tesys. Sold in lots of 50 units. Ambient air temperature for operation is from -40 to 130 °C conforming to IEC 60216-1 and VDE 0304-T21. Multi standards certified (UL, CSA, VDE, GL, DNV).
QTY
  • Product Description
  • Specifications
Linergy TR is terminal block for Linergy. It belongs to linergy passthrough terminal block with 2.5 mm² nominal cross section. The rated operational voltage is 600V conforming to CSA/UL and 500V conforming to EN/IEC 60947-7-1. The rated current is 22A conforming to EN/IEC 60947-7-1 and 20A conforming to CSA and UL. It has blue surface treatment Mounting by clip-on and top connection by double-level 2x2 push-in terminals. It could be connection without tool and disconnection by flat screwdriver. It is compatible with spacial enclosures for PrismaSeT G, PrismaSeT P, PrismaSeT HD, PrismaSeT Pack 250, PanelSeT, Mureva Enclosure, PrismaSeT XS, Tesys. Sold in lots of 50 units. Ambient air temperature for operation is from -40 to 130 °C conforming to IEC 60216-1 and VDE 0304-T21. Multi standards certified (UL, CSA, VDE, GL, DNV).
  • Physical Attributes
    • Color : Blue
    • Wire Stripping Length : 10 mm
  • Complementary Attributes
    • Line Rated Current : 20-20 A CSA, 20-20 A UL, 22-22 A EN/IEC 60947-7-1, 19.5-19.5 A
    • Ue Rated Operational Voltage : 600 V CSA, 500 V EN/IEC 60947-7-1, 440 V, 600 V UL
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SI
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Cable Cross Section : 0.2-2.5 mm², solid without cable end0.14-2.5 mm², flexible without cable end, 0.14-4 mm², solid with cable end, 0.2-2.5 mm², flexible with cable end
    • Creep Resistance : 500 CTI (> 400 kB) IEC 60093, 500 CTI (> 400 kB) VDE 0303-T30
    • Dielectric Loss : 0.01 at 1 MHz IEC 60250, 0.01 at 1 MHz VDE 0303-T4
    • Material : polyamide 6/6: insulating case, copper alloy: connector and screw, copper alloy: commoning link, chromium-nickel steel: spring
    • Mounting Mode : clip-on
    • Product Or Component Type : terminal block
    • Range : Linergy
    • Resistivity : 10000 MΩ.m IEC 60093, 10000 MΩ.m VDE 0303-T30
    • Surface Resistance : 1000 GΩ IEC 60093, 1000 GΩ VDE 0303-T30
    • Tool Type : connection without tool, disconnection flat screwdriver
    • Connections Terminals : 1 x push-in upstream, 1 x push-in downstream
    • Carbon Footprint Of The Distribution Phase A4 : 0.001631052, 0 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0 kg CO2 eq., 0.032124186
    • Carbon Footprint Of The Installation Phase A5 : 0.001472538, 0 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 0.1 kg CO2 eq., 0.077554975
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 4 kg CO2 eq., 4.4787
    • Certificate Agency : CSA, GL, UL, VDE
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-10
    • Return Indicator : N
    • Stocking Flag : Y
    • Stock Policy : 2
    • Use Carbon Footprint : 4.4787
    • Weee Applicability : Component
    • Weee Scope : Out
    • Weee Exclusion Rationale : Component not in scope – non independent function
    • Scope Perimeter : At least in Europe
    • Rohs Eur In Scope : No
    • Rohs Eur Status : Compliant
    • Rohs Eur Conformity Date : 1402
    • Rohs Eur Full Compliance Status : Compliant
    • China Rohs In Scope : No
    • China Rohs Label : 1
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 2
    • Tier : 2
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Compatibility Code : terminal block
    • Connection Position : inclined
    • Device Short Name : TRP
    • Dielectric Constant : 3.7 at 1 MHz
    • Dielectric Strength : 1000 V IEC 60243-1
    • Flame Retardance : V0 0.8 mm UL 94
    • Halogen Free Status : Halogen free plastic parts product
    • Nominal Cross Section : 2.5 mm²
    • Number Of Terminals : 2
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Name : Linergy TR
    • Quantity Per Set : set of 50
    • Range Of Product : Linergy
    • Returnability : No
    • Software Version : v5.9.4
    • Sustainable Packaging : Yes
    • Terminal Block Level : 2
    • Terminal Block Type : passthrough
    • Total Lifecycle Carbon Footprint : 5 kg CO2 eq.
    • Accessory Separate Part Category : connection accessory
    • Silicone Free : Yes
    • Warranty In Months : 18
    • Pep Code : ENVPEP2309019_V1
    • Database Version : 2022-01
    • Pep Verification Date : 2023-12-03
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent external review
    • Data Source : extrapolated product
    • Functional-unit Description : Connect during 20 years 2 clamping units between 2 or more wires with a rated connecting capacity 19 A, a rated cross-section 2.5 mm2, a rated voltage 550 V, a short-time withstand current 0.3 kA.
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unit
    • Reference Lifetime, In Y : 20
    • Energy Model - Manufacturing [A1-a3] : Electricity Mix; Production mix; Low voltage; GE
    • Energy Model - Installation [A5] : Electricity Mix; Production mix; Low voltage; UE-27
    • Energy Model - Use [B6] : Electricity Mix; Production mix; Low voltage; UE-27
    • Energy Model - End Of Life [C1-c4] : Electricity Mix; Production mix; Low voltage; UE-27
    • Recyclability Potential, In % : 33
    • Offer Owner Code : 190788
    • Pn : 1
    • Height Nominal : 55 mm
    • Length Total : 78 mm
    • Width Nominal : 5.2 mm
    • Climate Change - Fossil Fuels ( Kg Co2 Eq.) Operational Energy Use [B6] : 4.4727
    • Climate Change - Total ( Kg Co2 Eq.) Operational Energy Use [B6] : 4.4787
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Operational Energy Use [B6] : 114.1
    • Ecotoxicity (Fresh Water) (Ctue) Operational Energy Use [B6] : 48.232
    • Ionizing Radiation, Human Health (Kbq Of U235 Equiv.) Operational Energy Use [B6] : 6.6592
    • Total Use Of Primary Energy During The Life Cycle (Mj) Operational Energy Use [B6] : 136.02
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Operational Energy Use [B6] : 21.911
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : 114.1
    • Use Of Renewable Primary Energy, Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : 21.911
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Ambient Air Temperature For Operation : -40-130 °C IEC 60216-1, -40-130 °C IEC 60216-1, -40-130 °C VDE 0304-T21, -40-130 °C VDE 0304-T21-40-130 °C IEC 60216-1, -40-130 °C IEC 60216-1, -40-130 °C VDE 0304-T21
    • Product Compatibility : Spacial enclosures
    • Take Back : No
    • Reach Free Shvc : Yes
    • Halogene Performance : Halogen free plastic parts product
    • Recycled Metal Content At Cr Level : 0 %
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Silicon Free : Yes
    • Carbon Footprint : 4.591482751
    • Environmental Disclosure : ENVPEP2309019_V1
    • Eu Rohs Directive : Compliant
    • Halogen Content Performance : Halogen free plastic parts product
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Free Of Svhc : Yes
    • Pep Code : ENVPEP2309019_V1
    • Pep Verification Date : 2023-12-03
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : terminal block
    • Range Of Product : Linergy
  • ETIM
    • ETIM 8 : EC000897
    • ETIM 9 : EC000897
  • Input Attributes
    • Number Of Measurement Input : 4
  • Specifications
    • Country of Origin : Brazil, China, France, Poland, United States