power meter PowerLogic PM5110, modbus, up to 15th Harmonic, 1DO 33 alarms

BASIC POWER METER CL 0.5 SERI

SQDMETSEPM5110 METSEPM5110 3606480613982
1231.68 / EA
http://schema.org/OutOfStock
  • Depth: 2.83 in
  • IsSustainable: Yes
  • Number of Outputs: 1 Digital
This device is a flush-mount energy meter with a 96mm by 96mm backlit LCD display. The meter provides Class 0.5S accuracy per IEC 62053-22 standard and 64 samples per cycle. The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor and up to 15th Harmonic. The meter will function in a 50Hz or 60Hz network and accepts supply voltage ranging from 100 to 415 VAC and 125 to 250 VDC. Line rated current for this meter is 1A or 5A input and will support Single Phase and Neutral, Three Phase, or Three Phase and Neutral configurations. The range of measurement voltage between Phases is 35 to 690 VAC at 47 to 63 Hz. Measurement range between Phase and Neutral is 20 to 400VAC at 47 to 63 Hz. Communication protocol is Modbus RTU and ASCII 2 wires with RS485 port support. The meter also has one digital pulse output and 33 configurable alarms. Product dimensions are as follows: width 3.78 inches (96 millimetres), depth 2.83 inches (72 millimetres), height 3.78 inches (96 millimetres) and product weight 13.4 onces (380 g).
QTY
  • Product Description
  • Features
  • Specifications
This device is a flush-mount energy meter with a 96mm by 96mm backlit LCD display. The meter provides Class 0.5S accuracy per IEC 62053-22 standard and 64 samples per cycle. The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor and up to 15th Harmonic. The meter will function in a 50Hz or 60Hz network and accepts supply voltage ranging from 100 to 415 VAC and 125 to 250 VDC. Line rated current for this meter is 1A or 5A input and will support Single Phase and Neutral, Three Phase, or Three Phase and Neutral configurations. The range of measurement voltage between Phases is 35 to 690 VAC at 47 to 63 Hz. Measurement range between Phase and Neutral is 20 to 400VAC at 47 to 63 Hz. Communication protocol is Modbus RTU and ASCII 2 wires with RS485 port support. The meter also has one digital pulse output and 33 configurable alarms. Product dimensions are as follows: width 3.78 inches (96 millimetres), depth 2.83 inches (72 millimetres), height 3.78 inches (96 millimetres) and product weight 13.4 onces (380 g).
  • Prop 65
    • WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
  • Communications & Management Attributes
    • Communication Port Protocol : Modbus RTU and ASCII 9.6, 19.2 and 38.4 kbauds even/odd or none - 2 wires 2500 V, JBUS
    • Communication Port Support : RS485
  • Conformance Attributes
    • Product Certifications : CE conforming to IEC 61010-1, cULus conforming to UL 61010-1
    • Standards : UL 61010-1, EN 50470-3, EN 50470-1, IEC 62053-22:2020, IEC 60529, IEC 62053-24, IEC 61557-12:2015, IEC 62053-23:2020, IEC 62052-11:2020, IEC 62052-31:2015
  • Complementary Attributes
    • US Rated Supply Voltage : 90...450 V AC 45...65 Hz, 100...300 V DC
    • Maximum Power Consumption In VA : 11 VA 415 V
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SI
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
    • Market Segmentation Id : RESIDENTIAL, COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Residential, Commercial, Industrial
    • Data Recording : time stamping, min/max of instantaneous values
    • Electromagnetic Compatibility : voltage dips and interruptions immunity test class A conforming to IEC 61000-4-11, limits for harmonic current emissions class A conforming to IEC 61000-3-2, electrostatic discharge level 4 conforming to IEC 61000-4-2, conducted RF disturbances level 3 conforming to IEC 61000-4-6, magnetic field at power frequency level 4 conforming to IEC 61000-4-8, conducted and radiated emissions - test level: 150 kHz...80 MHz class B conforming to EN 55022, immunity to conducted disturbances - test level: 150 kHz...80 MHz conforming to IEC 61000-4-6, electrical fast transient/burst immunity test conforming to IEC 61000-4-4, radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3, surge immunity test class B conforming to IEC 61000-4-5, voltage dips and interruptions immunity test conforming to IEC 61000-4-11
    • Market Segment : buildings small building cost management: billing: main incomer, buildings small building cost management: billing: sub feeder, buildings medium building cost management: billing: main incomer, buildings medium building cost management: billing: sub feeder, buildings large building cost management: billing: main incomer, buildings large building cost management: billing: sub feeder, buildings multi-site cost management: billing: main incomer, buildings multi-site cost management: billing: sub feeder, data center cost management: billing: main incomer, data center cost management: billing: sub feeder, healthcare cost management: billing: main incomer, healthcare cost management: billing: sub feeder, industry cost management: billing: main incomer, industry cost management: billing: sub feeder, buildings small building cost management: cost allocation: main incomer, buildings small building cost management: cost allocation: sub feeder, buildings medium building cost management: cost allocation: main incomer, buildings medium building cost management: cost allocation: sub feeder, buildings large building cost management: cost allocation: main incomer, buildings large building cost management: cost allocation: sub feeder, buildings multi-site cost management: cost allocation: main incomer, buildings multi-site cost management: cost allocation: sub feeder, data center cost management: cost allocation: main incomer, data center cost management: cost allocation: sub feeder, healthcare cost management: cost allocation: main incomer, healthcare cost management: cost allocation: sub feeder, industry cost management: cost allocation: main incomer, industry cost management: cost allocation: sub feeder, buildings small building network management: main incomer, buildings small building network management: sub feeder, buildings medium building network management: main incomer, buildings medium building network management: sub feeder, buildings large building network management: sub feeder, buildings multi-site network management: sub feeder, data center network management: sub feeder, healthcare network management: sub feeder, industry network management: sub feeder
    • Measurement Accuracy : active energy +/- 0.5 %, reactive energy +/- 2 %, active power +/- 0.5 %, apparent power +/- 0.5 %, frequency +/- 0.05 %, power factor +/- 0.5, current +/- 0.5 %, voltage +/- 0.5 %, apparent energy +/- 0.5 %, reactive power +/- 2 %
    • Measurement Voltage : 35-760 V AC 45...65 Hz between phases, 20-440 V AC 45...65 Hz between phase and neutral
    • Ride Through Time : 80 ms 120 V AC typical, 100 ms 230 V AC typical, 100 ms 415 V AC typical, 50 ms 125 V DC typical
    • Type Of Measurement : current, voltage, frequency, power factor, energy, active and reactive power
    • Carbon Footprint Of The Distribution Phase A4 : 0.06523067065820948, 0.1 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 1.0182764848915156, 1 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0 kg CO2 eq., 0.027333678458057422
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 14 kg CO2 eq., 13.690464535148205
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 167 kg CO2 eq., 167.0655433140378
    • Connections Terminals : voltage circuit screw terminal block4, control circuit screw terminal block2, current transformer screw terminal block6, input/output circuit screw terminal block6, RS485 link screw terminal block4
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-01-09
    • HTML Description : PM5110 Power Meter w Modbus - upto 15th H - 1DO 33alarms - flush mount
    • Manufacturer : Schneider Electric
    • Device Type : Relay, Control & Measurement - measuring, monitoring device
    • Serviceability : Yes
    • Traceability : Yes
    • Field Service Division : DPIBS
    • Average Life Duration : 15 year(s)
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1305025_V3
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status Id : COMPLIANT_WITH_EXEMPTIONS
    • China ROHS In Scope : Yes
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • WD Status : 1 - GSC certified
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Compatibility Code : PM5110
    • Device Short Name : PM5110
    • Energy Efficiency Optimized : False
    • Frequency Measurement Range : 45-65 Hz
    • Mounting Support : framework
    • Package Weight Lbs : 478.000 g
    • Power Quality Analysis : up to the 15th harmonic
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : power meter
    • Range : PowerLogic
    • Returnability : Yes
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 182 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Relationship Type : Compatible relationship
    • Pep Code : ENVPEP1305025EN
    • Pep Verification Date : 2025-09-24
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
    • Functional Unit Description : To measure and monitor electrical parameters over a 10-year period, the device consumes 3.25 watts in active mode (39.50% time) and 2.6 watts in standby mode (60% time), resulting in a total energy consumption of 249.11 kWh. It operates within a supply voltage range of 90-450V AC and 100-300V DC, with a network frequency of 50Hz or 60Hz. The device can measure current (5-8500mA), voltage (35-760V AC, 20-400V DC), and frequency (45-65Hz), ensuring accurate and reliable monitoring in accordance with relevant standards.
    • Functional Unit Unit : unit
    • Product Kit Identifier : N
    • Product Manager : SEVERINO MUSSI
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : -25-70 °C meter, -25-70 °C meter, -20-70 °C display, -20-70 °C display, -25--20 °C with reduced performance) display, -25--20 °C with reduced performance) display, -25--20 °C with reduced performance) display
    • EU ROHS Directive : Compliant By Exemption​, Compliant with Exemptions
    • IP Degree Of Protection : IP54 display: conforming to IEC 60529, IP30 rear: conforming to IEC 60529
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 181.86684868319378
    • Circularity Profile : ENVEOLI1305025_V3
    • Environmental Disclosure : ENVPEP1305025EN
    • Operating Altitude : 6561.68 ft (2000 m) CAT III
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Relative Humidity : 5-95 % 50-50 °C non-condensing
    • Pep Code : ENVPEP1305025EN
    • Pep Verification Date : 2025-09-24
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : power meter
  • Output Attributes
    • Number Of Outputs : 1 digital
  • Input Attributes
    • Analogue Input Type : voltage (impedance 5 MOhm), current (impedance <= 0.3 mOhm)
    • Number Of Inputs : 0
  • Specifications
    • Depth : 2.83 in