PM3250 power meter - RS485

PM3200 POWER METER SERIAL OUT

SQDMETSEPM3250 METSEPM3250 785901009979
904.65 / EA
http://schema.org/OutOfStock
  • Certifications: CE EN 61557-12 Power Monitor), CE EN/IEC 61326-1 EMC), CE IEC 61010-1 Safety), CULus EN 61010-1 Safety), CULus UL 61010-1 Safety), EAC Sub-meter), RCM, UKCA BS EN 61010-1 Safety), UKCA BS EN 61326-1 EMC), UKCA BS EN 61557-12 Power Monitor)
  • Depth: 70 mm
  • Height: 95 mm
  • IsSustainable: Yes
  • Line Rated Current: 1 A, 5 A
  • Mounting Type: Clip-On
  • Net Weight: 0.26 kg
  • Number of Outputs: 0
  • Standard: ANSI C12.20, BS EN 61010-1, BS EN 61010-2-30, BS EN 61326-1, BS EN 61557-12, BS EN 62052-11, BS EN 62053-21, BS EN 62053-22, BS EN 62053-23, EN 61010-1, EN 61010-2-30, EN 61326-1, EN 61557-12, EN 62052-11, EN 62052-22, EN 62052-23, EN 62053-21, IEC 61010-1, IEC 61010-2-30, IEC 61326-1, IEC 61557-12, IEC 62052-11, IEC 62053-21, IEC 62053-22, IEC 62053-23, UL 61010-1, UL 61010-2-30
  • Storage Temperature: -40-85 °C
  • Warranty Length: 18 mth
  • Width: 90 mm
PM3250 DIN mount energy meter with a 128 by 96 pixel backlit, LCD display. The meter provides Class 0.5S accuracy per IEC 62053-22 standard and 32 samples per cycle. The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor, Apparent Power, Total Harmonic Distortion and up to 15th Harmonic. The meter will function in a 50Hz or 60Hz network and accepts supply voltage ranging from 100 to 277VAC, 173 to 480VAC and 100 to 300VDC. Line rated current for this meter is 1A or 5A input and will support Single Phase, Single Phase and Neutral or Three Phase configurations. Direct measurement range is 50 to 570VAC, with an external VT 570 to 999000VAC. The range of measurement voltage between Phases is 80 to 570VAC at 45 to 65 Hz. Measurement range between Phase and Neutral is 50 to 330VAC at 45 to 65 Hz. Communication protocol is Modbus RTU and ASCII 2 wires with RS485 port support. The meter offers event recording with up to 5 alarms. Product dimensions are as follows: width 3.54 in (90 mm), depth 2.76in (70 mm), height 3.74 in (95 mm) and product weight 9.17 oz (260 g).
QTY
  • Product Description
  • Specifications
PM3250 DIN mount energy meter with a 128 by 96 pixel backlit, LCD display. The meter provides Class 0.5S accuracy per IEC 62053-22 standard and 32 samples per cycle. The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor, Apparent Power, Total Harmonic Distortion and up to 15th Harmonic. The meter will function in a 50Hz or 60Hz network and accepts supply voltage ranging from 100 to 277VAC, 173 to 480VAC and 100 to 300VDC. Line rated current for this meter is 1A or 5A input and will support Single Phase, Single Phase and Neutral or Three Phase configurations. Direct measurement range is 50 to 570VAC, with an external VT 570 to 999000VAC. The range of measurement voltage between Phases is 80 to 570VAC at 45 to 65 Hz. Measurement range between Phase and Neutral is 50 to 330VAC at 45 to 65 Hz. Communication protocol is Modbus RTU and ASCII 2 wires with RS485 port support. The meter offers event recording with up to 5 alarms. Product dimensions are as follows: width 3.54 in (90 mm), depth 2.76in (70 mm), height 3.74 in (95 mm) and product weight 9.17 oz (260 g).
  • Environment
    • Ambient Air Temperature For Operation : -25-70 °C
    • Electromagnetic Compatibility : electrostatic discharge level 4 conforming to IEC 61000-4-2 || susceptibility to electromagnetic fields level 3 conforming to IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 || surge immunity test level 4 conforming to IEC 61000-4-5 || conducted RF disturbances level 3 conforming to IEC 61000-4-6 || magnetic field at power frequency - test level: 0.5 mT conforming to IEC 61000-4-8 || conducted and radiated emissions class B conforming to EN 55022
    • Pollution Degree : 2
    • Ambient Air Temperature For Storage : -40-85 °C
    • Relative Humidity : 5-95 % 50-50 °C
    • Ip Degree Of Protection : IP40 front panel: conforming to IEC 60529 || IP20 body: conforming to IEC 60529
    • Overvoltage Category : III
    • Operating Altitude : < 9842.52 ft (3000 m)
  • Contractual warranty
    • Warranty : 18 months
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP111275EN
    • Sustainable Offer Status : Green Premium product
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • China Rohs Regulation : X
    • Circularity Profile : ENVEOLI111258EN
    • Eu Rohs Directive : Compliant with Exemptions
  • Complementary
    • Network Frequency : 60 Hz || 50 Hz
    • Communication Port Support : RS485
    • Power Quality Analysis : up to the 15th harmonic
    • Height : 95 mm
    • Measurement Voltage : 50-330 V AC 45...65 Hz direct || 50-330 V AC 45...65 Hz phase to neutral || 80-570 V AC 45...65 Hz direct || 80-570 V AC 45...65 Hz phase to phase || 570-999000 V AC 45...65 Hz with external VT
    • Sampling Rate : 32 samples/cycle
    • Standards : BS EN 61557-12 || IEC 61557-12 || EN 61557-12 || BS EN 61326-1 || IEC 61326-1 || EN 61326-1 || BS EN 62052-11 || IEC 62052-11 || EN 62052-11 || BS EN 62053-21 || IEC 62053-21 || EN 62053-21 || BS EN 62053-22 || IEC 62053-22 || EN 62052-22 || BS EN 62053-23 || IEC 62053-23 || EN 62052-23 || BS EN 61010-1 || EN 61010-1 || IEC 61010-1 || UL 61010-1 || BS EN 61010-2-30 || IEC 61010-2-30 || EN 61010-2-30 || UL 61010-2-30 || ANSI C12.20
    • Number Of Outputs : 0
    • Type Of Measurement : active and reactive power || apparent power || current || voltage || energy || power factor || frequency || total current harmonic distortion THD (I) || total voltage harmonic distortion THD (U)
    • Communication Port Protocol : Modbus 9.6...38.4 kbauds
    • Frequency Measurement Range : 45-65 Hz
    • Power Consumption In Va : 5 VA
    • Display Resolution : 128 x 96 pixels
    • Product Certifications : CE IEC 61010-1 safety) || CE EN 61557-12 power monitor) || CE EN/IEC 61326-1 EMC) || UKCA BS EN 61010-1 safety) || UKCA BS EN 61557-12 power monitor) || UKCA BS EN 61326-1 EMC) || cULus EN 61010-1 safety) || cULus UL 61010-1 safety) || EAC sub-meter) || RCM
    • Number Of Inputs : 0
    • Net Weight : 0.26 kg
    • Depth : 70 mm
    • Measurement Current : 0.02-1.2 A || 0.05-6 A
    • Information Displayed : tariff 4)
    • [Us] Rated Supply Voltage : 100...277 V AC 45...65 Hz || 173...480 V AC 45...65 Hz || 100...300 V DC
    • Mounting Mode : clip-on
    • Measurement Accuracy : current 0.3 % 0.5...6 A || current 0.5 % 0.1...1.2 A || voltage 0.3 % 50...330 V || voltage 0.3 % 80...570 V
    • Mounting Support : DIN rail
    • Poles Description : 1P + N || 3P || 3P + N
    • Data Recording : time stamping || min/max of instantaneous values || 5 alarms
    • Line Rated Current : 5 A || 1 A
    • Analogue Input Type : current 0...5 A || current 0...1 A
    • Width : 90 mm
    • Display Type : Backlit LCD
    • Device Application : multi-tariff || power monitoring || sub billing
    • Accuracy Class : class 0.5S active energy IEC 62053-22 || class 1 active energy IEC 62053-21 || class 2 reactive energy IEC 62053-23 || class C active energy EN 50470-3
  • Specifications
    • Product Or Component Type : power meter
    • Product Name : PowerLogic PM3000
    • Range : PowerLogic
    • Device Short Name : PM3250