PM3250 power meter - RS485

PM3200 POWER METER SERIAL OUT

SQDMETSEPM3250 METSEPM3250 785901009979
956.14 / EA
http://schema.org/OutOfStock
  • Depth: 2.76 in
  • IsSustainable: Yes
  • Number of Outputs: 0
  • Warranty Length: 18 mth
PM3250 DIN mount energy meter with a 128 by 96 pixel backlit, LCD display. The meter provides Class 0.5S accuracy per IEC 62053-22 standard and 32 samples per cycle. The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor, Apparent Power, Total Harmonic Distortion and up to 15th Harmonic. The meter will function in a 50Hz or 60Hz network and accepts supply voltage ranging from 100 to 277VAC, 173 to 480VAC and 100 to 300VDC. Line rated current for this meter is 1A or 5A input and will support Single Phase, Single Phase and Neutral or Three Phase configurations. Direct measurement range is 50 to 570VAC, with an external VT 570 to 999000VAC. The range of measurement voltage between Phases is 80 to 570VAC at 45 to 65 Hz. Measurement range between Phase and Neutral is 50 to 330VAC at 45 to 65 Hz. Communication protocol is Modbus RTU and ASCII 2 wires with RS485 port support. The meter offers event recording with up to 5 alarms. Product dimensions are as follows: width 3.54 in (90 mm), depth 2.76in (70 mm), height 3.74 in (95 mm) and product weight 9.17 oz (260 g).
QTY
  • Product Description
  • Features
  • Specifications
PM3250 DIN mount energy meter with a 128 by 96 pixel backlit, LCD display. The meter provides Class 0.5S accuracy per IEC 62053-22 standard and 32 samples per cycle. The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor, Apparent Power, Total Harmonic Distortion and up to 15th Harmonic. The meter will function in a 50Hz or 60Hz network and accepts supply voltage ranging from 100 to 277VAC, 173 to 480VAC and 100 to 300VDC. Line rated current for this meter is 1A or 5A input and will support Single Phase, Single Phase and Neutral or Three Phase configurations. Direct measurement range is 50 to 570VAC, with an external VT 570 to 999000VAC. The range of measurement voltage between Phases is 80 to 570VAC at 45 to 65 Hz. Measurement range between Phase and Neutral is 50 to 330VAC at 45 to 65 Hz. Communication protocol is Modbus RTU and ASCII 2 wires with RS485 port support. The meter offers event recording with up to 5 alarms. Product dimensions are as follows: width 3.54 in (90 mm), depth 2.76in (70 mm), height 3.74 in (95 mm) and product weight 9.17 oz (260 g).
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Communications & Management Attributes
    • Communication Port Protocol : Modbus 9.6...38.4 kbauds
    • Communication Port Support : RS485
  • Conformance Attributes
    • Product Certifications : CE IEC 61010-1 safety), CE EN 61557-12 power monitor), CE EN/IEC 61326-1 EMC), UKCA BS EN 61010-1 safety), UKCA BS EN 61557-12 power monitor), UKCA BS EN 61326-1 EMC), cULus EN 61010-1 safety), cULus UL 61010-1 safety), EAC sub-meter), RCM
  • Complementary Attributes
    • US Rated Supply Voltage : 100...277 V AC 45...65 Hz, 173...480 V AC 45...65 Hz, 100...300 V DC
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SI
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
    • Market Segmentation Id : RESIDENTIAL, COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Residential, Commercial, Industrial
    • Data Recording : time stamping, min/max of instantaneous values, 5 alarms
    • Electromagnetic Compatibility : electrostatic discharge level 4 conforming to IEC 61000-4-2, susceptibility to electromagnetic fields level 3 conforming to IEC 61000-4-3, electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4, surge immunity test level 4 conforming to IEC 61000-4-5, conducted RF disturbances level 3 conforming to IEC 61000-4-6, magnetic field at power frequency - test level: 0.5 mT conforming to IEC 61000-4-8, conducted and radiated emissions class B conforming to EN 55022
    • Market Segment : buildings small building cost management: billing: sub feeder, buildings medium building cost management: billing: sub feeder, buildings large building cost management: billing: sub feeder, buildings multi-site cost management: billing: sub feeder, data center cost management: billing: sub feeder, healthcare cost management: billing: sub feeder, industry cost management: billing: sub feeder, buildings small building cost management: cost allocation: sub feeder, buildings medium building cost management: cost allocation: sub feeder, buildings large building cost management: cost allocation: sub feeder, buildings multi-site cost management: cost allocation: sub feeder, data center cost management: cost allocation: sub feeder, healthcare cost management: cost allocation: sub feeder, industry cost management: cost allocation: sub feeder
    • Measurement Accuracy : current 0.3 % 0.5...6 A, current 0.5 % 0.1...1.2 A, voltage 0.3 % 50...330 V, voltage 0.3 % 80...570 V
    • Measurement Voltage : 50-330 V AC 45...65 Hz direct, 50-330 V AC 45...65 Hz phase to neutral, 80-570 V AC 45...65 Hz direct, 80-570 V AC 45...65 Hz phase to phase, 570-999000 V AC 45...65 Hz with external VT
    • Type Of Measurement : active and reactive power, apparent power, current, voltage, energy, power factor, frequency, total current harmonic distortion THD (I), total voltage harmonic distortion THD (U)
    • Carbon Footprint Of The Distribution Phase A4 : 1.060470267718614, 1 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.8158451539357584, 0.8 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0 kg CO2 eq., 0.008852425292849813
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 11 kg CO2 eq., 11.45845167280039
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 92 kg CO2 eq., 92.11646185236035
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-06-18
    • HTML Description : The PowerLogic PM3000 series power meters are a cost-attractive, feature-rich metering offer, ideal for helping you better understand the true condition of your electrical installations. The PM3250 includes Modbus Output
    • Manufacturer : Square D
    • Device Type : Relay, Control & Measurement - measuring, monitoring device
    • Serviceability : Yes
    • Traceability : Yes
    • Field Service Division : DPIBS
    • Average Life Duration : 15 year(s)
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI111258EN_V1
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status Id : COMPLIANT_WITH_EXEMPTIONS
    • China ROHS In Scope : Yes
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : No
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • WD Status : 1 - GSC certified
    • Dangerous Goods Code : LITHIUM METAL BATTERIES IN EQUIP. CELL : ≤ 1g AND ≤ 4 CELLS
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Compatibility Code : PM3250
    • Device Short Name : PM3250
    • Energy Efficiency Optimized : False
    • Frequency Measurement Range : 45-65 Hz
    • Information Displayed : tariff 4)
    • Mounting Support : DIN rail
    • Package Weight Lbs : 416.700 g
    • Power Consumption In VA : 5 VA
    • Power Quality Analysis : up to the 15th harmonic
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : power meter
    • Range : PowerLogic
    • Returnability : Yes
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 105 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Relationship Type : up-selling relationship
    • Pep Code : ENVPEP1112075EN
    • Pep Verification Date : 2025-03-27
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed3-2023 06 06
    • Type Of Verification For The Pep : Independent external review
    • Functional Unit Description : Other switchgear and controlgear solutions mentioned in the scope (e.g. fuses TC32, all-or-nothing relays TC94, Measuring relays and protection equipment TC95), apply the general rules of PCR and mention in the accompanying report the functional unit, the reference product characteristics, the reference lifetime and the use scenario which are applied consistently with the relevant IEC technical standards.PowerLogic™ PM32xx series is a power meter with an LCD display. The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor, Apparent Power, Total Harmonic Distortion and up to 15th Harmonic during 10 years.
    • Functional Unit Unit : unit
    • Product Kit Identifier : N
  • Environment Attributes Main
    • EU ROHS Directive : Compliant By Exemption​, Compliant with Exemptions
    • IP Degree Of Protection : IP40 front panel: conforming to IEC 60529, IP20 body: conforming to IEC 60529
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 105.46008137210795
    • Ambient Air Temperature For Operation : -25-70 °C
    • Circularity Profile : ENVEOLI111258EN_V1
    • Environmental Disclosure : ENVPEP1112075EN
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Relative Humidity : 5-95 % 50-50 °C
    • Pep Code : ENVPEP1112075EN
    • Pep Verification Date : 2025-03-27
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed3-2023 06 06
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : power meter
  • Output Attributes
    • Number Of Outputs : 0
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Input Attributes
    • Analogue Input Type : current 0...5 A, current 0...1 A
    • Number Of Inputs : 0
  • Specifications
    • Depth : 2.76 in