PM3250 power meter - RS485

PM3250 power meter - RS485

SQDMETSEPM3250 METSEPM3250 785901009979
619.00 / EA
  • Amperage: 5 A
  • Certifications: CE Conforming To EN 61010-1, CULus Conforming To UL 61010-1, UL
  • Country of Origin: China
  • Depth: 70 mm
  • Height: 3.74 in, 95 mm
  • Mounting Type: Clip-On
  • Number of Outputs: 0
  • Standard: EN 50470-1, EN 50470-3, EN 61010-1, EN 61557-12, IEC 61557-12, IEC 62052-11, UL 61010-1
  • Warranty Length: 18 mth
  • Weight: 0.26 kg, 0.57 lb
  • Width: 3.54 in, 90 mm
PM3250 DIN mount energy meter with a 128 by 96 pixel backlit, LCD display. The meter provides Class 0.5S accuracy per IEC 62053-22 standard and 32 samples per cycle. The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor, Apparent Power, Total Harmonic Distortion and up to 15th Harmonic. The meter will function in a 50Hz or 60Hz network and accepts supply voltage ranging from 100 to 277VAC, 173 to 480VAC and 100 to 300VDC. Line rated current for this meter is 1A or 5A input and will support Single Phase, Single Phase and Neutral or Three Phase configurations. Direct measurement range is 50 to 570VAC, with an external VT 570 to 999000VAC. The range of measurement voltage between Phases is 80 to 570VAC at 45 to 65 Hz. Measurement range between Phase and Neutral is 50 to 330VAC at 45 to 65 Hz. Communication protocol is Modbus RTU and ASCII 2 wires with RS485 port support. The meter offers event recording with up to 5 alarms. Product dimensions are as follows: width 3.54 in (90 mm), depth 2.76in (70 mm), height 3.74 in (95 mm) and product weight 9.17 oz (260 g).
  • Product Description
  • Specifications
PM3250 DIN mount energy meter with a 128 by 96 pixel backlit, LCD display. The meter provides Class 0.5S accuracy per IEC 62053-22 standard and 32 samples per cycle. The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor, Apparent Power, Total Harmonic Distortion and up to 15th Harmonic. The meter will function in a 50Hz or 60Hz network and accepts supply voltage ranging from 100 to 277VAC, 173 to 480VAC and 100 to 300VDC. Line rated current for this meter is 1A or 5A input and will support Single Phase, Single Phase and Neutral or Three Phase configurations. Direct measurement range is 50 to 570VAC, with an external VT 570 to 999000VAC. The range of measurement voltage between Phases is 80 to 570VAC at 45 to 65 Hz. Measurement range between Phase and Neutral is 50 to 330VAC at 45 to 65 Hz. Communication protocol is Modbus RTU and ASCII 2 wires with RS485 port support. The meter offers event recording with up to 5 alarms. Product dimensions are as follows: width 3.54 in (90 mm), depth 2.76in (70 mm), height 3.74 in (95 mm) and product weight 9.17 oz (260 g).
  • Ordering And Shipping Details
    • Country Of Origin : CN
    • GTIN : 00785901009979
    • Category : 09786 - SE ENTRY POWER METER
    • Nbr. Of Units In Pkg. : 1
    • Returnability : No
    • Discount Schedule : PL1
  • Contractual Warranty
    • Warranty : 18 months
  • Offer Sustainability
    • EU RoHs Directive : Compliant
    • Mercury Free : Yes
    • WEEE : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • California Proposition 65 : WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
    • Green Premium Status : Green Premium product
  • Environment
    • Ambient Air Temp For Storage : -40…185 °F (-40…85 °C)
    • Pollution Degree : 2
    • IP Degree Of Protection : IP40 front panel: conforming to IEC 60529 || IP20 body: conforming to IEC 60529
    • Relative Humidity : 5…95 % at 50 °C
    • Electromagnetic Compatibility : Electrostatic discharge level 4 conforming to IEC 61000-4-2 || Susceptibility to electromagnetic fields level 3 conforming to IEC 61000-4-3 || Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 || 1.2/50 µs shock waves immunity test level 4 conforming to IEC 61000-4-5 || Conducted RF disturbanceslevel 3 IEC 61000-4-6 || Magnetic field at power frequency - test level: 0.5 mT conforming to IEC 61000-4-8 || Conducted and radiated emissions class B conforming to EN 55022
    • Overvoltage Category : III
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Ambient Air Temp For Op : -25…55 °C
  • Complementary
    • Information Displayed : Tariff (4)
    • Frequency Measurement Range : 45…65 Hz
    • Analogue Input Type : Current 0...5 A || Current 0...1 A
    • Device Application : Multi-tariff || Power monitoring || Sub billing
    • Mounting Support : DIN rail
    • Display Type : Backlit LCD
    • Product Weight : 0.57 lb(US) (0.26 kg)
    • Power Quality Analysis : up to the 15th harmonic
    • Depth : 70 mm
    • Sampling Rate : 32 samples/cycle
    • Accuracy Class : Class 0.5S active energy IEC 62053-22 || Class 1 active energy IEC 62053-21 || Class 2 reactive energy IEC 62053-23 || Class C active energy conforming to EN 50470-3
    • Type Of Network : 1P + N || 3P || 3P + N
    • Number Of Inputs : 0
    • Product Certifications : CE conforming to EN 61010-1 || CULus conforming to UL 61010-1 || UL
    • Power Consumption In Va : 5 VA
    • Number Of Outputs : 0
    • Communication Port Protocol : Modbus 9.6...38.4 kbauds
    • Width : 3.54 in (90 mm)
    • Measurement Voltage : 50…330 V AC 45...65 Hz direct || 50…330 V AC 45...65 Hz phase to neutral || 80…570 V AC 45...65 Hz direct || 80…570 V AC 45...65 Hz phase to phase || 570…999000 V AC 45...65 Hz with external VT
    • Height : 3.74 in (95 mm)
    • Communication Port Support : RS485
    • Network Frequency : 60 Hz || 50 Hz
    • Data Recording : Time stamping || Min/max of instantaneous values || 5 alarms
    • In Rated Current : 5 A || 1 A
    • Measurement Current : 0.02…1.2 A || 0.05…6 A
    • Mounting Mode : Clip-on
    • Type Of Measurement : Active and reactive power || Apparent power || Current || Voltage || Energy || Power factor || Frequency || Total current harmonic distortion THD (I) || Total voltage harmonic distortion THD (U)
    • Standards : IEC 61557-12 || EN 50470-3 || EN 61010-1 || EN 50470-1 || EN 61557-12 || UL 61010-1 || IEC 62052-11
    • Measurement Accuracy : Current 0.3 % 0.5...6 A || Current 0.5 % 0.1...1.2 A || Voltage 0.3 % 50...330 V || Voltage 0.3 % 80...570 V
    • Supply Voltage : 100...277 V AC 45...65 Hz || 173...480 V AC 45...65 Hz || 100...300 V DC
    • Display Resolution : 128 x 96 pixels
  • Main
    • Device Short Name : PM3250
    • Range : PowerLogic
    • Product Name : PowerLogic PM3000
    • Product Or Component Type : Power meter