Multi 9 - N40N - MCB - 1P + N - 16 A - C Curve - 240 V - 10 kA

Multi 9 - N40N - MCB - 1P + N - 16 A - C Curve - 240 V - 10 kA

SQDM9P22616 M9P22616 785901563556
163.62 / EA
  • Depth: 78 mm
  • Height: 81 mm
  • Line Rated Current: 16 A, 50 °C
  • Mounting Type: Clip-On
  • Net Weight: 0.115 kg
  • Standard: EN/IEC 60947-2
  • Storage Temperature: -40-70 °C
  • Strip Length: 13 mm
  • Width: 18 mm
This Multi9 N40N is a low voltage miniature circuit breaker (MCB). It is a 1P+N circuit breaker with 1 protected pole, 16A rated current and C tripping curve. The Icu rated short circuit breaking capacity is up to 10kA at 240VAC conforming to EN/IEC 60898-1 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. Its fast closing mechanism, overvolatge resistance and high performance limitation improve its service life. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 20000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV. The operating frequency is 50Hz or 60Hz. The product can be clipped on a DIN rail. Its width is 2 pitches of 9mm. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 18mm x (H) 81mm x (D) 78mm. The weight is 0.115kg. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -25°C to 70°C. The storage temperature is -40°C to 70°C.
  • Product Description
  • Specifications
This Multi9 N40N is a low voltage miniature circuit breaker (MCB). It is a 1P+N circuit breaker with 1 protected pole, 16A rated current and C tripping curve. The Icu rated short circuit breaking capacity is up to 10kA at 240VAC conforming to EN/IEC 60898-1 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. Its fast closing mechanism, overvolatge resistance and high performance limitation improve its service life. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 20000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV. The operating frequency is 50Hz or 60Hz. The product can be clipped on a DIN rail. Its width is 2 pitches of 9mm. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 18mm x (H) 81mm x (D) 78mm. The weight is 0.115kg. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -25°C to 70°C. The storage temperature is -40°C to 70°C.
  • Mounting Mode : clip-on
  • Mounting Support : DIN rail
  • Product Or Component Type : miniature circuit-breaker
  • Standards : EN/IEC 60947-2
  • Color : Gray
  • Electrical Durability : 20000 cycles
  • [Ui] Rated Insulation Voltage : 500 V AC 50/60 Hz EN/IEC 60947-2
  • Contact Position Indicator : yes
  • Curve Code : C
  • 9 Mm Pitches : 2
  • Ambient Air Temperature For Operation : -25-70 °C
  • Ip Degree Of Protection : IP20IEC 60529 || IP40 modular enclosure)IEC 60529
  • Local Signalling : ON/OFF indication
  • Mechanical Durability : 20000 cycles
  • Tightening Torque : 2-2 N.m top or bottom
  • Maximum Height : 81 mm
  • Neutral Position : left
  • [Uimp] Rated Impulse Withstand Voltage : 4 kVEN/IEC 60947-2
  • Line Rated Current : 16 A 50 °C EN/IEC 60947-2
  • Suitability For Isolation : yes EN/IEC 60947-2
  • Breaking Capacity Code : N
  • Trip Unit Technology : thermal-magnetic
  • Device Application : distribution
  • [Ue] Rated Operational Voltage : 240 V AC 50/60 Hz between phase and neutral
  • Poles Description : 1P + N
  • Provision For Padlocking : padlockable
  • Magnetic Tripping Limit : 8.5 x In +/- 20 % AC
  • Connections - Terminals : tunnel type terminal top or bottom) 0.75-16 mm² - rigid || tunnel type terminal top or bottom) 0.33-10 mm² - flexible || tunnel type terminal top or bottom) 0.33-10 mm² - flexible with ferrule
  • Device Short Name : N40N
  • Range : Multi 9
  • Earth-Leakage Protection : separate block
  • Product Name : Multi 9 N40
  • Limitation Class : 3 EN/IEC 60947-2
  • Breaking Capacity : 10 kA Icu 240 V AC 50/60 Hz between phase and neutral EN/IEC 60947-2
  • Wire Stripping Length : 13 mm top or bottom
  • Pollution Degree : 3 EN/IEC 60947-2
  • Number Of Protected Poles : 1
  • Ambient Air Temperature For Storage : -40-70 °C
  • Maximum Width : 18 mm
  • Control Type : toggle
  • Network Type : AC
  • Net Weight : 0.115 kg
  • [Ics] Rated Service Breaking Capacity : 7.5 kA 75 % EN/IEC 60947-2 - 240 V AC 50/60 Hz
  • Range Of Product : Multi 9
  • Relative Humidity : 95-95 % 55-55 °C
  • Network Frequency : 50/60 Hz
  • Maximum Depth : 78 mm
  • Tropicalisation : 2 IEC 60068-1