Multi9 - N40 Vigi - 1P + N - 16 A - C curve - class AC - 240 V - 30 mA - 6 kA

Multi9 - N40 Vigi - 1P + N - 16 A - C curve - class AC - 240 V - 30 mA - 6 kA

SQDM9D11616 M9D11616 785901280002
426.60 / EA
  • Amperage: 16 A
  • Country of Origin: Spain
  • Depth: 2.76 in, 70 mm
  • Height: 3.19 in, 81 mm
  • Mounting Type: Clip-On
  • Standard: EN/IEC 60947-2, EN/IEC 61009-1
  • Strip Length: 0.51 in, 13 mm
  • Voltage: 240 V
  • Weight: 0.125 kg, 0.28 lb
  • Width: 1.42 in, 36 mm
This Multi9 N40 Vigi is a modular residual current breaker with overcurrent protection (RCBO). It is a 1P+N circuit breaker with 1 protected pole, 16A In rated current and C tripping curve. The earth leakage protection class is AC type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. The Icu rated short circuit breaking capacity is up to 6kA according EN/IEC 60947-2 standard. The Icn rated short circuit breaking capacity is up to 6000 A according EN/IEC 61009-1 standard. This product protects against short circuit, cable overload, electrical shock by indirect contact and fire hazards. A green strip on the toggle guarantees opening of all the poles in safety conditions. This product is compliant with EN/IEC 61009-1 and EN/IEC 60947-2 standards. It has an electrical endurance going up to 20000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 400VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 4. The product color is light grey (RAL7035). The dimensions are (W) 36mm x (H) 81mm x (D) 70mm. The weight is 125g. It has an IP20 degree of protection (as per IEC/EN 60529 standard) and becomes IP40 once in modular enclosure. The operating temperature is from -5°C to 60°C. The storage temperature is from -30°C to 70°C.
  • Product Description
  • Specifications
This Multi9 N40 Vigi is a modular residual current breaker with overcurrent protection (RCBO). It is a 1P+N circuit breaker with 1 protected pole, 16A In rated current and C tripping curve. The earth leakage protection class is AC type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. The Icu rated short circuit breaking capacity is up to 6kA according EN/IEC 60947-2 standard. The Icn rated short circuit breaking capacity is up to 6000 A according EN/IEC 61009-1 standard. This product protects against short circuit, cable overload, electrical shock by indirect contact and fire hazards. A green strip on the toggle guarantees opening of all the poles in safety conditions. This product is compliant with EN/IEC 61009-1 and EN/IEC 60947-2 standards. It has an electrical endurance going up to 20000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 400VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 4. The product color is light grey (RAL7035). The dimensions are (W) 36mm x (H) 81mm x (D) 70mm. The weight is 125g. It has an IP20 degree of protection (as per IEC/EN 60529 standard) and becomes IP40 once in modular enclosure. The operating temperature is from -5°C to 60°C. The storage temperature is from -30°C to 70°C.
  • Main
    • Trip Unit Technology : Thermal-magnetic
    • Suitability For ISOlation : Yes EN/IEC 60947-2
    • Earth-Leak Protect Time Delay : Instantaneous
    • Network Type : AC
    • Product Name : Multi 9 N40 Vigi
    • Curve Code : C
    • Number Of Protected Poles : 1
    • In Rated Current : 16 A 122 °F (50 °C) EN/IEC 60947-2
    • Device Application : Distribution
    • Product Or Component Type : Residual current breaker with overcurrent protection (RCBO)
    • Breaking Capacity : 6 kA Icu 240 V AC 50 Hz EN/IEC 60947-2 || 6000 A Icn 240 V AC 50 Hz EN/IEC 61009-1
    • Earth-Leakage Sensitivity : 30 mA
    • Range : Multi 9
    • Utilisation Category : Category A EN/IEC 60947-2
    • Neutral Position : Left
    • Earth-Leakage Protection Class : Type AC
    • Device Short Name : N40 Vigi
    • Poles Description : 1P + N
  • Environment
    • IP Degree Of Protection : IP20IEC 60529 || IP40 (modular enclosure) conforming to IEC 60529
    • Ambient Air Temp For Op : 23…140 °F (-5…60 °C)
    • Standards : EN/IEC 61009-1 || EN/IEC 60947-2
    • Tropicalisation : 2 IEC 60068-1
    • Overvoltage Category : IV
    • Relative Humidity : 95 % 131 °F (55 °C)
    • Electromagnetic Compatibility : 8/20 µs impulse withstand, 250 A
    • Ambient Air Temp For Storage : -22…158 °F (-30…70 °C)
    • Pollution Degree : 3 EN/IEC 60947-2
  • Ordering And Shipping Details
    • GTIN : 00785901280002
    • Country Of Origin : ES
    • Category : 00908 - C60N SUPPLEMENTARY PROTECTORS
    • Returnability : No
    • Nbr. Of Units In Pkg. : 1
    • Discount Schedule : DE2
  • Offer Sustainability
    • Halogen Content Performance : Halogen free plastic parts product
    • EU RoHs Directive : Compliant
    • WEEE : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Green Premium Status : Green Premium product
    • Mercury Free : Yes
  • Complementary
    • Network Frequency : 50 Hz
    • Mechanical Durability : 20000 cycles
    • Wire Stripping Length : 0.51 in (13 mm) top or bottom
    • Magnetic Tripping Limit : 8.5 x In +/- 20 % AC
    • Ui Rated Insulation Voltage : 400 V AC 50 Hz EN/IEC 60947-2
    • Depth : 2.76 in (70 mm)
    • Electrical Durability : 20000 cycles
    • Width : 1.42 in (36 mm)
    • Height : 3.19 in (81 mm)
    • Product Weight : 0.28 lb(US) (0.125 kg)
    • Uimp Rated Imp Wstd Voltage : 4 kVEN/IEC 60947-2
    • Rated Brking And Making Cap : Idm 4500 A 240 V AC 50 Hz EN/IEC 61009-1
    • Earth-Leakage Protection : Integrated
    • Connections - Terminals : Tunnel type terminal top or bottom) 0.00…0.02 in² (0.75…16 mm²) - rigid || Tunnel type terminal top or bottom) 0.00…0.02 in² (0.33…10 mm²) - flexible || Tunnel type terminal top or bottom) 0.00…0.02 in² (0.33…10 mm²) - flexible with ferrule
    • Ue Rated Operational Voltage : 240 V AC 50 Hz
    • 9 mm Pitches : 4
    • Local Signalling : Fault indication || ON/OFF indication
    • Surge Current : 250 A
    • Colour : Gray
    • Limitation Class : 3 EN/IEC 61009-1
    • Control Type : Toggle
    • Mounting Mode : Clip-on
    • Tightening Torque : 17.70 lbf.in (2 N.m) top or bottom
    • Ics Rated Service Breaking Cap : 4.5 kA 75 % EN/IEC 60947-2 - 240 V AC 50 Hz
    • Mounting Support : DIN rail
    • Contact Position Indicator : Yes
    • Provision For Padlocking : Padlockable
    • Resid Current Tripping Techno : Voltage independent