Residual current circuit breaker (RCCB), Multi9 ID, 4P, 40A, AC type, 30mA

Residual current circuit breaker (RCCB), Multi9 ID, 4P, 40A, AC type, 30mA

SQDM9R11440 M9R11440 3606480578373
367.52 / EA
http://schema.org/OutOfStock
  • Country of Origin: Spain
  • Depth: 73 mm
This Multi ID product is a residual current circuit breaker (RCCB). It is a 4P circuit breaker with 40A In rated current, 30mA earth leakage sensitivity and AC type protection class. This product protects against electrical shock by direct or indirect contact and fire hazards. The tripping upon fault is indicated by a red mechanical status indicator on the front panel. This product is dedicated to original equipment manufacturers (OEM) and control panel builders in indisutrial and tertiary buildings. It is compliant with IEC/EN 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 400A. The (Inc/IΔc) conditional rated short circuit current is 10kA. It has an electrical endurance going up to 2000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 380VAC to 415VAC. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 6kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 8. The product colour is light grey (RAL7035). The dimensions are (W) 72mm x (H) 81mm x (D) 73mm. The weight is 0.45kg. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is from -5°C to 40°C. The storage temperature is from -40°C to 60°C.
QTY
  • Features
  • Specifications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Physical Attributes
    • Color : Gray
    • Wire Stripping Length : 15 mm for top or bottom connection
  • Complementary Attributes
    • Line Rated Current : 40 A
    • Rated Breaking And Making Capacity : Idm 400 A EN/IEC 61008-1
  • Important Information Attributes
    • Persona Type Ids : EU, OM, OM8
    • Persona Type Names : End User, Original Equipment Manufacturer, OEM - Control Panelbuilder
    • Connection Pitch : 18 mm between phase and neutral, 18 mm between phases
    • Connections - Terminals : tunnel type terminal (top or bottom)1-35 mm² - rigid, tunnel type terminal (top or bottom)1-25 mm² - flexible, tunnel type terminal (top or bottom): 3 cable(s) 16-16 mm² - rigid, tunnel type terminal (top or bottom): 3 cable(s) 10-10 mm² - flexible, tunnel type terminal (top or bottom)1-25 mm² - flexible with ferrule
    • Carbon Footprint Of The Distribution Phase [A4] : 0.0533304331592528, 0.1 kg CO2 eq.
    • Carbon Footprint Of The End-of-life Phase [C1 To C4] : 0.995199755014716, 1 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase [A5] : 0 kg CO2 eq., 0.023890037635503
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 4 kg CO2 eq., 3.8844737047135
    • Carbon Footprint Of The Use Phase [B2, B3, B4, B6] : 58 kg CO2 eq., 58.165
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-08-13
    • Return Indicator : N
    • Stocking Flag : Y
    • Stock Policy : 2
    • Device Type : LV equipment - Low voltage circuit breaker
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 15 year(s)
    • Use Carbon Footprint : 58.165
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant
    • Rohs Eur Conformity Date : 0844
    • Rohs Eur Full Compliance Status : Compliant
    • China Rohs In Scope : Yes
    • China Rohs Label : 1
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 2
    • Tier : 2
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Market Segmentation Id : COMMERCIAL
    • Market Segmentation : Commercial
    • Product Kit Identifier : N
    • Contact Position Indicator : yes
    • Control Type : toggle
    • Device Application : distribution
    • Device Short Name : ID
    • Electrical Durability : 2000 cycles
    • Electromagnetic Compatibility : 8/20 µs impulse withstand, 250 A EN/IEC 61008-1
    • Energy Efficiency Optimized : False
    • Local Signalling : ON, OFF, fault trip
    • Locking Options Description : padlocking device
    • Mechanical Durability : 20000 cycles
    • Mounting Mode : clip-on
    • Mounting Support : DIN rail
    • Network Frequency : 50 Hz
    • Network Type : AC
    • Neutral Position : left
    • Number Of Poles : 4P
    • Poles Description : 4P
    • Power Losses Per Pole : 3.6 W
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Name : Multi9 ID
    • Product Or Component Type : residual current circuit breaker (RCCB)
    • Range : Multi9
    • Range Of Product : Multi9
    • Residual Current Tripping Technology : voltage independent
    • Returnability : No
    • Software Version : v5.9.4
    • Sustainable Packaging : Yes
    • Tightening Torque : 3.5-3.5 N.m top or bottom
    • Total Lifecycle Carbon Footprint : 63 kg CO2 eq.
    • Total Power Losses : 10.8 W
    • Tropicalisation : 2 IEC 60068-1
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Eleakage Prot Class : type AC
    • Rated Current 3 : 40 A
    • Earth Leakage Sensitivity 1 : 30 mA
    • Pep Code : ENVPEP2301023EN
    • Database Version : 2022-01
    • Pep Verification Date : 2025-04-20
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent external review
    • Data Source : extrapolated product
    • Functional-unit Description : Protect during 20 years the installation against overloads and short-circuits and people and premises at risk of fire or explosion against insulation defects in circuit with assigned voltage 400V and rated current 40A. This protection is ensured in accordance with the following parameters:& 10- Number of poles 4& 10- Sensitivity 300mA& 10- Type of differential protection AC
    • Functional-unit Quantity : 1
    • Functional-unit Unit : Unit
    • Reference Lifetime, In Y : 20
    • Energy Consumption On Product Lifetime, In Kwh : 141.912
    • Energy Model - Manufacturing [A1-a3] : Electricity Mix; Low voltage; 2018; Spain, SP
    • Energy Model - Installation [A5] : Electricity Mix; Production mix; Low voltage; UE-27
    • Energy Model - Use [B6] : Electricity Mix; Production mix; Low voltage; UE-27
    • Energy Model - End Of Life [C1-c4] : Electricity Mix; Production mix; Low voltage; UE-27
    • Recyclability Potential, In % : 59
    • Height Nominal : 81 mm
    • Width Nominal : 72 mm
    • Certificate Agency : CE
    • [Ue] Rated Operational Voltage : 380...415 V AC 50 Hz
    • [Ui] Rated Insulation Voltage : 440 V AC 50 Hz EN/IEC 61008-1
    • [Uimp] Rated Impulse Withstand Voltage : 6 kVEN/IEC 61008-1
    • Earth-leakage Sensitivity : 30 mA
    • Rated Conditional Short-circuit Current : Inc 10 kA
    • Earth-leakage Protection Class : type AC
    • Earth-leakage Protection Time Delay : instantaneous
    • Halogen-free Status : Product contains halogen above thresholds
    • Nbr. Of Units In Pkg. : 1
    • Package Weight(Lbs) : 350.000 g
    • Take-back : No
    • Warranty (In Months) : 18
    • Acidification (Ap) (Mole Of H+ Equiv) Operational Energy Use [B6] : 0.3319
    • Climate Change - Fossil Fuels ( Kg Co2 Eq.) Operational Energy Use [B6] : 58.087
    • Climate Change - Total ( Kg Co2 Eq.) Operational Energy Use [B6] : 58.165
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Operational Energy Use [B6] : 1481.9
    • Ecotoxicity (Fresh Water) (Ctue) Operational Energy Use [B6] : 626.39
    • Impacts Related To Land Use/Soil Quality (-) Operational Energy Use [B6] : 1.1573
    • Ionizing Radiation, Human Health (Kbq Of U235 Equiv.) Operational Energy Use [B6] : 86.483
    • Non-hazardous Waste Disposed Of (Kg) Operational Energy Use [B6] : 8.3687
    • Total Use Of Primary Energy During The Life Cycle (Mj) Operational Energy Use [B6] : 1766.4
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Operational Energy Use [B6] : 284.56
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : 1481.9
    • Use Of Renewable Primary Energy, Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : 284.56
  • Environment Attributes Main
    • Ambient Air Temperature For Storage : -40-60 °C, -40-60 °C
    • Ip Degree Of Protection : IP20 conforming to IEC 60529, IP40 (modular enclosure) conforming to IEC 60529
    • Reach Regulation : Free of Substances of Very High Concern above the threshold, Reference contains Substances of Very High Concern above the threshold
    • Take Back : No
    • Reach Free Shvc : Yes
    • Halogene Performance : Product contains halogen above thresholds
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 63.1218939305229
    • 9 Mm Pitches : 8
    • Ambient Air Temperature For Operation : -5-40 °C-5-40 °C
    • Environmental Disclosure : ENVPEP2301023EN
    • Eu Rohs Directive : Compliant
    • Halogen Content Performance : Product contains halogen above thresholds
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Free Of Svhc : Yes
    • Relative Humidity : 95-95 % 55-55 °C
    • Pep Code : ENVPEP2301023EN
    • Pep Verification Date : 2025-04-20
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : residual current circuit breaker (RCCB)
    • Range Of Product : Multi9
  • ETIM
    • ETIM 8 : EC000003
    • ETIM 9 : EC000003
  • Surge Protection And Filtering Attributes
    • Surge Current : 250 A
  • Specifications
    • Country of Origin : Spain
    • Depth : 73 mm