Schneider Electric at Mayer

Residual current circuit breaker (RCCB), Multi9 ID, 2P, 40A, AC type, 300mA

RESIDUAL CURRENT SWITCH 240V 4

SQDM9R14240 M9R14240 3606480578359
261.30 / EA
http://schema.org/OutOfStock
This Multi ID product is a residual current circuit breaker (RCCB). It is a 2P circuit breaker with 40A In rated current, 300mA earth leakage sensitivity and AC type protection class. This product protects against electrical shock by indirect contact and fire hazards. The tripping upon fault is indicated by a red mechanical status indicator on the front panel. This product is dedicated to original equipment manufacturers (OEM) and control panel builders in indisutrial and tertiary buildings. It is compliant with IEC/EN 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 400A. The (Inc/IΔc) conditional rated short circuit current is 10kA. It has an electrical endurance going up to 2000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 220VAC to 240VAC. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 6kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 4. The product colour is light grey (RAL7035). The dimensions are (W) 36mm x (H) 81mm x (D) 73mm. The weight is 0.23kg. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is from -5°C to 40°C. The storage temperature is from -40°C to 60°C.
QTY
  • Product Description
  • Features
  • Specifications
This Multi ID product is a residual current circuit breaker (RCCB). It is a 2P circuit breaker with 40A In rated current, 300mA earth leakage sensitivity and AC type protection class. This product protects against electrical shock by indirect contact and fire hazards. The tripping upon fault is indicated by a red mechanical status indicator on the front panel. This product is dedicated to original equipment manufacturers (OEM) and control panel builders in indisutrial and tertiary buildings. It is compliant with IEC/EN 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 400A. The (Inc/IΔc) conditional rated short circuit current is 10kA. It has an electrical endurance going up to 2000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 220VAC to 240VAC. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 6kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 4. The product colour is light grey (RAL7035). The dimensions are (W) 36mm x (H) 81mm x (D) 73mm. The weight is 0.23kg. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is from -5°C to 40°C. The storage temperature is from -40°C to 60°C.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Physical Attributes
    • Wire Stripping Length : 15 mm for top or bottom connection, 15 mm for top or bottom connection
    • Color : Gray
  • Conformance Attributes
    • Product Certifications : CE
    • Standards : EN/IEC 61008-1
  • Complementary Attributes
    • Rated Breaking And Making Capacity : Idm 400 A EN/IEC 61008-1, Idm 400 A EN/IEC 61008-1, Idm 400 A EN/IEC 61008-1
    • Rated Conditional Short Circuit Current : Inc 10 kA, Inc 10 kA
    • UE Rated Operational Voltage : 220...240 V AC 50 Hz, 220...240 V AC 50 Hz, 220...240 V AC 50 Hz
    • UI Rated Insulation Voltage : 440 V AC 50 Hz EN/IEC 61008-1, 440 V AC 50 Hz EN/IEC 61008-1, 440 V AC 50 Hz EN/IEC 61008-1, 440 V AC 50 Hz EN/IEC 61008-1
    • UIMP Rated Impulse Withstand Voltage : 6 kVEN/IEC 61008-1, 6 kVEN/IEC 61008-1
    • Line Rated Current : 40 A
  • Important Information Attributes
    • Persona Type Ids : EU, OM, OM8
    • Persona Type Names : End User, Original Equipment Manufacturer, OEM - Control Panelbuilder
    • Connection Pitch : 18 mm between phase and neutral, 18 mm between phase and neutral
    • Electromagnetic Compatibility : 8/20 µs impulse withstand, 250 A EN/IEC 61008-1, 8/20 µs impulse withstand, 250 A EN/IEC 61008-1, 8/20 µs impulse withstand, 250 A EN/IEC 61008-1
    • Tightening Torque : 3.5-3.5 N.m top or bottom, 3.5-3.5 N.m top or bottom
    • Tropicalisation : 2 IEC 60068-1, 2 IEC 60068-1
    • Carbon Footprint Of The Distribution Phase A4 : 0.03620916082529047, 0 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.6756995180408616, 0.7 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0 kg CO2 eq., 0.016220348563137203
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 3 kg CO2 eq., 2.63739716262139
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 39 kg CO2 eq., 38.776666666666664
    • Connections Terminals : tunnel type terminal top or bottom) 1-35 mm² - rigid, tunnel type terminal top or bottom) 1-35 mm² - rigid, tunnel type terminal top or bottom) 1-35 mm² - rigid, tunnel type terminal top or bottom) 1-35 mm² - rigid, tunnel type terminal top or bottom) 1-25 mm² - flexible, tunnel type terminal top or bottom) 1-25 mm² - flexible, tunnel type terminal top or bottom) 1-25 mm² - flexible, tunnel type terminal top or bottom) 1-25 mm² - flexible, tunnel type terminal top or bottom) 3 16-16 mm² - rigid, tunnel type terminal top or bottom) 3 16-16 mm² - rigid, tunnel type terminal top or bottom) 3 16-16 mm² - rigid, tunnel type terminal top or bottom) 3 16-16 mm² - rigid, tunnel type terminal top or bottom) 3 16-16 mm² - rigid, tunnel type terminal top or bottom) 3 10-10 mm² - flexible, tunnel type terminal top or bottom) 3 10-10 mm² - flexible, tunnel type terminal top or bottom) 3 10-10 mm² - flexible, tunnel type terminal top or bottom) 3 10-10 mm² - flexible, tunnel type terminal top or bottom) 3 10-10 mm² - flexible, tunnel type terminal top or bottom) 1-25 mm² - flexible with ferrule, tunnel type terminal top or bottom) 1-25 mm² - flexible with ferrule, tunnel type terminal top or bottom) 1-25 mm² - flexible with ferrule, tunnel type terminal top or bottom) 1-25 mm² - flexible with ferrule
    • Auxiliaries : M9A26914, M9A26917, 26923, M9A26948, M9A26478, M9A26960, M9A26946, M9A27108, M9A26476, M9A27107
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-08-13
    • Device Type : LV equipment - Low voltage circuit breaker
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 15 year(s)
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant
    • ROHS EUR Full Compliance Status : Compliant
    • ROHS EUR Full Compliance Status Id : COMPLIANT
    • China ROHS In Scope : Yes
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • WD Status : 1 - GSC certified
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Market Segmentation Id : COMMERCIAL
    • Market Segmentation : Commercial
    • H And D Domain : Safety
    • H And D Subrange : Multi9 OEM ID XM RCCB
    • H And D Enrichment Assignment : yes
    • H And D Enrichment Function : RCCB
    • H And D Enrichment Class 3 : Earth leakage protection devices
    • H And D Enrichment Class 4 : RCCB
    • H And Dod Responsibility : Multi9
    • H And Dod Platform : RCD&Switches
    • Contact Position Indicator : yes
    • Device Short Name : ID
    • Earth Leakage Protection Class : type AC
    • Earth Leakage Protection Time Delay : instantaneous
    • Earth Leakage Sensitivity : 300 mA
    • Electrical Durability : 2000 cycles
    • Energy Efficiency Optimized : False
    • Halogen Free Status : Halogen free plastic parts product
    • Locking Options Description : padlocking device
    • Network Type : AC
    • Neutral Position : left
    • Package Weight Lbs : 198.000 g
    • Power Losses Per Pole : 3.6 W
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : residual current circuit breaker (RCCB)
    • Range : Multi9
    • Range Of Product : Multi9
    • Residual Current Tripping Technology : voltage independent
    • Returnability : Yes
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 42 kg CO2 eq.
    • Total Power Losses : 7.2 W
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Relationship Type : Compatible relationship
    • Pep Code : ENVPEP2301023EN
    • Pep Verification Date : 2025-04-19
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent external review
    • Functional Unit Description : Protect during 20 years people and premises at risk of fire or explosion against insulation defects in circuit with assigned voltage 400VAC and rated current 40A (In). This protection is ensured in accordance with the following parameters:& 10- Number of poles : 4& 10- Sensitivity : 300mA& 10- Type of differential protection : AC
    • Functional Unit Unit : Unit
    • Product Kit Identifier : N
  • Environment Attributes Main
    • EU ROHS Directive : Compliant​, Compliant
    • IP Degree Of Protection : IP20 conforming to IEC 60529, IP20 conforming to IEC 60529, IP40 (modular enclosure) conforming to IEC 60529, IP40 (modular enclosure) conforming to IEC 60529, IP40 (modular enclosure) conforming to IEC 60529
    • Reach Regulation : Free of Substances of Very High Concern above the threshold, Free of Substances of Very High Concern above the threshold
    • Relative Humidity : 95-95 % 55-55 °C, 95-95 % 55-55 °C
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Reach Free SHVC : Yes
    • Halogene Performance : Halogen free plastic parts product
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : X
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 42.142192856717344
    • 9 MM Pitches : 4
    • Ambient Air Temperature For Operation : -5-40 °C
    • Environmental Disclosure : ENVPEP2301023EN
    • Halogen Content Performance : Halogen free plastic parts product
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Free Of SVHC : Yes
    • Pep Code : ENVPEP2301023EN
    • Pep Verification Date : 2025-04-19
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : residual current circuit breaker (RCCB)
    • Range Of Product : Multi9